Web Analytics Made Easy - StatCounter

Tender for Srphc82281275-des-abbreviated Dapt Long -coronary Drug Eluting Stents With (1) Platinum Chromium Alloy (2) Coating Of Bioabsorbable Polymer Carrier For Activedrug Everolimus Shown To Be Effective In Preventing Neo-intimal Hyperplasia) (3) Stent Diameter Should Be From 2.5mm To 4mm. The Length Of The Stent Should Be From 12mm To 48 Mm. (4) The Strut Thickness Should Be 91 Micron Or Less. (5) Stent Delivery System Should Be Monorail (single Operator Exchange Or Rapid Exchange). (6) Stent Should Be Compatible With 5fr Guiding Catheter (7) Stent Design Should Be Open Cell Type. (8) Stent Should Be Approved By Dcgi. The Copy Of Dcgi Approval Should Be Enclosed In The Tender Bid. (9) The Long Term Efficacy And Safety Of The Stent, The Rates Of In-stent Restenosis (isr) And In-situ Thrombosis (ist) Should Be Documented / Published In Peer Reviewed Scientific Journals. (10) Safety Of Abbreviated (three Month) Dual Antiplatelet Therapy For High Bleeding Risk Patients Should Be Documented In Peer Reviewed Journals. (11) The Manufacturer/supplier Should Submit Proof Of Supply Of The Stent To A Major Government Institute. Bis Standards For The Drug Eluting Stent Are Not Available. (reference:bis Catalogue ).[quantity Tolerance (+/-): 5 %age , Item Category : Normal , Total Po Value Variation Permitted: Max 8 Lacs ] ] in Perambur - Tamil Nadu

Tender Details
Reference # :
45227573
Description :
Tenders for Srphc82281275-des-abbreviated Dapt Long -coronary Drug Eluting Stents With (1) Platinum Chromium Alloy (2) Coating Of Bioabsorbable Polymer Carrier For Activedrug Everolimus Shown To Be Effective In Preventing Neo-intimal Hyperplasia) (3) Stent Diameter Should Be From 2.5mm To 4mm. The Length Of The Stent Should Be From 12mm To 48 Mm. (4) The Strut Thickness Should Be 91 Micron Or Less. (5) Stent Delivery System Should Be Monorail (single Operator Exchange Or Rapid Exchange). (6) Stent Should Be Compatible With 5fr Guiding Catheter (7) Stent Design Should Be Open Cell Type. (8) Stent Should Be Approved By Dcgi. The Copy Of Dcgi Approval Should Be Enclosed In The Tender Bid. (9) The Long Term Efficacy And Safety Of The Stent, The Rates Of In-stent Restenosis (isr) And In-situ Thrombosis (ist) Should Be Documented / Published In Peer Reviewed Scientific Journals. (10) Safety Of Abbreviated (three Month) Dual Antiplatelet Therapy For High Bleeding Risk Patients Should Be Documented In Peer Reviewed Journals. (11) The Manufacturer/supplier Should Submit Proof Of Supply Of The Stent To A Major Government Institute. Bis Standards For The Drug Eluting Stent Are Not Available. (reference:bis Catalogue ).[quantity Tolerance (+/-): 5 %age , Item Category : Normal , Total Po Value Variation Permitted: Max 8 Lacs ] ]
Ownership :
Sector :
Tender Values
Value :
NA
EMD :
NA
Doc. Cost :
NA
Important Dates
Due date :
15 Jun, 2026
Open date :
15 Jun, 2026
Publish date :
16 May, 2026
Location
Location :
Perambur - Tamil Nadu ( IN )
Connect us via What's Up