Web Analytics Made Easy - StatCounter

Tender for Purchase Of Lab Equipments For Ice Dept - Purchase Of Lab Equipments For Ice Dept, I/p And P/i Converter (iemcode:g002) I/p Converter:(4 20) Ma To (3 15) Psi Conversion. P/i Converter:(3 15) Psi To (4 20) Ma Conversion. Air Filter Regulator (afr):20 Psi Regulated Air Supply. Built-in Current Source. 3 Digit Led Display For Process Indication. Power Supply: 230 V Ac, 50 Hz. Mounting:bench-top / Panel-mounted Trainer Configuration., Level Measurement Using Float And Sight Glass Indicator- Itemcode: G005specifications: Sight Glass Level Indicator. Float Type Level Indicator. Power Supply:230 V Ac, 50 Hz. Monoblock Pump:0.5 Hp / 1 Hp. Sump Tank., 8051develop Ment Board With Usb/rs 232 Cable To Connect With Computer (item Code: G008)specifications: Communication Interface:usb / Rs-232. On-board Facilities:8 Output Leds,8 Input Switches,ldr,reed Switch,8-bit Adc,8-bit Dac. Display Interfaces:seven-segment Display,16 2 Lcd Interface. Motor Interfacing:stepper Motor With Driver,dc Motor With H-bridge Driver, 8 Bit Adc/dac Interface Board (item Code: G009)specifications: Thermistor / Lm35 Input In One Channel. Variable Input (0 5) V In Another Channel. 8 Leds For Digital Output Indication.. Necessary Control Signals Provided For Adc0809. 8-bit Dac Using Dac0808. 8-bit Digital Input From Controller. Single-channel Dac Output:(0 10) V. Power Supply: 12 V Or 15 V For Analog Circuitry, Water Level Measurement Trainer Kit Using Capacitive Type Transducer (item Code: G020) Tabletop Model With Transparent Acrylic Tank Of Approximately 50 Cm Height. Capacitive Type Level Sensor For Continuous Level Measurement. Sensor Output: (4 20) Ma And/or (0 5) V With Built-in Signal Conditioning. Vertical Pump For Water Circulation From Sump To Tank. Flow Control Valve, Overflow, And Drainage Arrangement. Digital Display For Water Level Indication In Cm. Power Supply: 230 V Ac, 50 Hz, Single Phase. In-built Regulated Dc Power Supply For Sensor And Control Circuit. Mounted On Powder-coated Ms Frame For Laboratory Use. Suitable For Calibration And Study Of Capacitive Level Measurement., Flow Measurement Using Electromagn Etic Flow Meter(item Code: G021)specifications: Medium: Water (salt Water / Bore Well Water). Electromagnetic Flow Measurement: Instantaneous Flow Rate And Totalized Flow Indication. Electromagnetic Flow Meter: Integral Mounted Type. Power Supply: 90 260 V Ac, 50 Hz. Minimum Media Conductivity: 15 S/cm. Flow Rate Unit: M /hr. Operating Pressure: Up To 10 Kg/cm . Electrode Material: Ss-304 / Ss-316 / Ss 316l. Lining Material: Ptfe / Neoprene / Hard Rubber / Pfa. Line Size: 15 Nb 25 Nb. Flow Range: 0.1 10 M /hr. Connection Type: Flanged. Display: Digital Indication For Flow Rate And Totalized Flow. Water Pump: Submersible Type, 230 V Ac, 50 Hz. Water Tank: Approximately 20 25 Liters Capacity. Flow Control Valve Provided. Drain Valve And Overflow Arrangement Provided. Mounted On Powder-coated Ms Frame Suitable For Laboratory Use. in Tuticorin - Tamil Nadu

Tender Details
Reference # :
45365473
Description :
Tenders for Purchase Of Lab Equipments For Ice Dept - Purchase Of Lab Equipments For Ice Dept, I/p And P/i Converter (iemcode:g002) I/p Converter:(4 20) Ma To (3 15) Psi Conversion. P/i Converter:(3 15) Psi To (4 20) Ma Conversion. Air Filter Regulator (afr):20 Psi Regulated Air Supply. Built-in Current Source. 3 Digit Led Display For Process Indication. Power Supply: 230 V Ac, 50 Hz. Mounting:bench-top / Panel-mounted Trainer Configuration., Level Measurement Using Float And Sight Glass Indicator- Itemcode: G005specifications: Sight Glass Level Indicator. Float Type Level Indicator. Power Supply:230 V Ac, 50 Hz. Monoblock Pump:0.5 Hp / 1 Hp. Sump Tank., 8051develop Ment Board With Usb/rs 232 Cable To Connect With Computer (item Code: G008)specifications: Communication Interface:usb / Rs-232. On-board Facilities:8 Output Leds,8 Input Switches,ldr,reed Switch,8-bit Adc,8-bit Dac. Display Interfaces:seven-segment Display,16 2 Lcd Interface. Motor Interfacing:stepper Motor With Driver,dc Motor With H-bridge Driver, 8 Bit Adc/dac Interface Board (item Code: G009)specifications: Thermistor / Lm35 Input In One Channel. Variable Input (0 5) V In Another Channel. 8 Leds For Digital Output Indication.. Necessary Control Signals Provided For Adc0809. 8-bit Dac Using Dac0808. 8-bit Digital Input From Controller. Single-channel Dac Output:(0 10) V. Power Supply: 12 V Or 15 V For Analog Circuitry, Water Level Measurement Trainer Kit Using Capacitive Type Transducer (item Code: G020) Tabletop Model With Transparent Acrylic Tank Of Approximately 50 Cm Height. Capacitive Type Level Sensor For Continuous Level Measurement. Sensor Output: (4 20) Ma And/or (0 5) V With Built-in Signal Conditioning. Vertical Pump For Water Circulation From Sump To Tank. Flow Control Valve, Overflow, And Drainage Arrangement. Digital Display For Water Level Indication In Cm. Power Supply: 230 V Ac, 50 Hz, Single Phase. In-built Regulated Dc Power Supply For Sensor And Control Circuit. Mounted On Powder-coated Ms Frame For Laboratory Use. Suitable For Calibration And Study Of Capacitive Level Measurement., Flow Measurement Using Electromagn Etic Flow Meter(item Code: G021)specifications: Medium: Water (salt Water / Bore Well Water). Electromagnetic Flow Measurement: Instantaneous Flow Rate And Totalized Flow Indication. Electromagnetic Flow Meter: Integral Mounted Type. Power Supply: 90 260 V Ac, 50 Hz. Minimum Media Conductivity: 15 S/cm. Flow Rate Unit: M /hr. Operating Pressure: Up To 10 Kg/cm . Electrode Material: Ss-304 / Ss-316 / Ss 316l. Lining Material: Ptfe / Neoprene / Hard Rubber / Pfa. Line Size: 15 Nb 25 Nb. Flow Range: 0.1 10 M /hr. Connection Type: Flanged. Display: Digital Indication For Flow Rate And Totalized Flow. Water Pump: Submersible Type, 230 V Ac, 50 Hz. Water Tank: Approximately 20 25 Liters Capacity. Flow Control Valve Provided. Drain Valve And Overflow Arrangement Provided. Mounted On Powder-coated Ms Frame Suitable For Laboratory Use.
Ownership :
Sector :
Tender Values
Value :
NA
EMD :
1,855
Doc. Cost :
NA
Important Dates
Due date :
13 Jun, 2026
Open date :
15 Jun, 2026
Publish date :
29 May, 2026
Location
Location :
Tuticorin - Tamil Nadu ( IN )
Connect us via What's Up