Description :
Tenders for Rate Contract Of Supplement Medicine And Diagnostic - Description Of Supplement Medicine & Diagnostics, Albendazole Tablet 400 Mg, Calcium Tablet (500 Mg Elemental + Vit D3 250 Iu), Ifa Red: Prophylactic (preventative) Dose: Typically One Tablet Daily (containing 60-100 Mg Elemental Iron And 400-500 G Folic Acid), Usually Starting After The First 12 Weeks Of Pregnancy And Continuing For A Minimum Of 180 Days.therapeutic Dose: If You Are Diagnosed With Anemia, Your Doctor May Increase The Dosage To Two Tablets Daily.postpartum: It Is Often Recommended To Continue Taking These Supplements For At Least Three Months After Childbirth., Digital Hemoglobinometer: Measurement Range: Typically 0 - 25.6 G/dl (or 0 - 256 G/l).methodology: Reflectance Photometry Or Absorbance Spectrophotometry.sample Type: Capillary, Venous, Or Arterial Whole Blood.sample Volume: Very Small, Usually Between 8 L And 15 L.time To Results: Under 15 - 60 Seconds.memory Capacity: Stores 500 To 1,000 Test Results With Date, Time, And Patient Id.power: Rechargeable Battery Or Aa Batteries., Digital Hemoglobinometer Strips: Sample Type: Fresh Capillary Whole Blood (finger Prick) Or Venous Whole Blood.blood Volume: 10 L To 30 L (approximately One Drop).measuring Range: Usually 3.0 To 25.6 G/dl.result Time: Between 15 To 60 Seconds, Depending On The Testing Mechanism.operating Temperature: Stable Between 2 C To 40 C.shelf Life: Typically 18 To 24 Months From The Date Of Manufacture When Stored Properly. Digital Hemoglobinometer Will Be Free As Per Company Policy., Glucometer: Measurement Range: Typically 10 Mg/dl To 600 Mg/dl (or 0.6 Mmol/l To 33.3 Mmol/l). Results Falling Above Or Below This Range Are Generally Flagged As "high" Or "low".testing Method: Usually Employs Electrochemical Biosensors (like Glucose Oxidase Or Glucose Dehydrogenase) To Generate A Detectable Electrical Current From The Blood Sample.accuracy Standards: Devices Generally Conform To En Iso 15197:2015 Performance Criteria, Which Require 95% Of Results To Fall Within 15 Mg/dl Of Lab Values At Concentrations 100 Mg/dl, And Within 15% At Concentrations 100 Mg/dl.hematocrit Range: Most Meters Accommodate Blood Hematocrit Levels Between 10% And 65%.power Source: Usually Powered By 1 To 2 Standard Coin-cell Batteries (e.g., Cr2032).physical Specs: Lightweight And Compact, Typically Weighing Between 40g And 75g., Glucometer Strips: Blood Sample Volume\(0.3\text{ \mu L}\) To \(1.0\text{ \mu L}\) (capillary Blood)measurement Time5 Secondsmeasurement Range10 Mg/dl To 600 Mg/dl (varies Slightly By Meter)enzyme Technologyglucose Oxidase (god) Or Glucose Dehydrogenase (gdh)shelf Life12 To 24 Months (usually 3 To 6 Months After Opening)operating Conditions4 C To 30 C (storage), 10-90% Relative Humidity. Glucometer Will Be Free As Per Company Policy., Ors: Recommended By The World Health Organization (who) And Unicef- Sodium Chloride (nacl): 2.6 Gglucose (anhydrous): 13.5 Gpotassium Chloride (kcl): 1.5 Gtrisodium Citrate Dihydrate: 2.9 Gtotal Weight: 20.5 G