Web Analytics Made Easy - StatCounter

Tender for A.r. &amp; Maintenance Of 196 Hmps Flats At South Avenue Under Sub Div-1 Of Ded-201, New Delhi. (sh: Replacement Of Defective Electrical Accessories I/c Supply Of Material).subwork/packages:replacement Of Defective Electrical Accessories I/c Supply Of Material. - Supplying, Installation, Testing &amp; Commissioning Of Flood Light, Powder Coated Pressure Die Cast Aluminium Body With Built In Or Separate Driver As Per The Requirement With Driver Efficiency >85%, Input Voltage : Input Voltage: 140-270 Volt Ac, Freq 50/60 Hz, Operating Temp Range - 5 Deg. To 50 Deg. Centigrade, Internal Surge Protection Of 5 Kv L,n,e As Per Iec 61000-4-5, Driver Efficiency >85%, Thd < 10% As Per Iec 61000-3-2, P. F.≥0.95, Ip-66, Ik-10, Cri >70, Under Voltage And Over Voltage Protection, Emiemc As Per Cispr -15, Lenses For Beam Angle 30 Deg- 120 Deg As Per The Application And The Project Requirement Deg., Suitable Tilt Able Fitting, Life Time (led, Driver &amp; Electrical Circuitry) Of Minimum 50000 Burning Hours With 70% Of Initial Lumen Maintained Till Life Ends As Per Lm80 Extrapolation Ies Tm-21-11 Report, Cct 3000°k/4000°k /5700°k /6500°k (as Per Ansi Bin), Sdcm(standard Deviation Color Matching) <5, Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Relevant Bis Standard Complete In All Respect I/c External Connections With 1.5 Sq Mm Frls/hffr, Pvc Insulated Copper Conductor Single Core Cable And Earthing Etc. As Required With Minimum 5 Year Oem Warranty. System Lumen Efficacy 105 <120 Lm/watt Output. Lm79 &amp; Lm80 Test Report And All Testing Required For Led Fixtures As Per Bis Shall Be Submitted.. Shape Size And Cct Shall Be As Approved By Engineer-in-charge As Per Requirement. (thermal Management: Heat Sink Of Aluminium Housing Such That Led Junction Temperature Shall Not Rise Above 90°c). (make: Havells/ Wipro/ Philips/ Crompton/ Regent) 1.1 50 Watt , 1.5 Sq Mm Frls Pvc Insulated Single Core Copper Conductor Cable., , 4 Sq Mm Frls Pvc Insulated Single Core Copper Conductor Cable., , 6 Sq Mm Frls Pvc Insulated Single Core Copper Conductor Cable., , S.p. 5/6 A, One Way Modular Switch, , S.p. 5/6 A, Two Way Modular Switch, , S.p. 15/16 A, One Way Modular Switch, , 3 Pin 5/6 A Modular Socket Outlet, , 6 Pin 15/16 A Modular Socket Outlet, , Modular Bell Push, , Stepped Type Modular Fan Regulator (2 Module), , Telephone Socket Outlet Modular Type, , T.v. Socket Outlet Modular Type, , Modular Blanking Plate, , Modular Base &amp; Cover Plate For 1 Or 2 Module, , Modular Base &amp; Cover Plate For 3 Module, Modular Base &amp; Cover Plate For 4 Module, , Modular Base &amp; Cover Plate For 6 Module, , Modular Base &amp; Cover Plate For 8 Module, , Modular Base &amp; Cover Plate For 12 Module, , Modular Gi Box For 2 Module, , Modular Gi Box For 3 Module, , Modular Gi Box For 4 Module, , Modular Gi Box For 6 Module, , Modular Gi Box For 8 Module, , Modular Gi Box For 12 Module, , 3 Pole Mccb, 125 A, 16ka, , 6 Amps. To 32 Amps. Ratings, Sp Mcb, "c" Curve, 10 Ka Breaking Capacity, , 40 Amps., 2 Pole Isolator, , 63 Amps., 2 Pole Isolator, , 100amp., 4 Pole Isolator, , Supply Of Led Batten Light (system Lumen Efficacy ≥105 <120 Lm/watt) Of Following Body Materials. Powder Coated Die Cast /extruded Aluminium Body (thickness > 1.20 Mm) (make: Havells/ Wipro/ Philips/crompton/regent), , 18-22 Watt, , 40 Watt, , Supply Of Led Down Lighter (smd Type) (system Lumen Efficacy ≥ 105 <120 Lm/watt) Of Following Body Materials. Powder Coated Die Cast/extruded Aluminium Body Including Trim With Aluminium Reflector (make: Havells/ Wipro/ Philips/ Crompton/regent), , 5-7 Watt, , 8-10 Watt, , 12-15 Watt, , Supply Of Led Bulb 9 Watt B-22/e- 27 Type (3 Star &amp; Above) (white/yellow Colour) (make: Havells/ Wipro/ Philips/ Crompton/regent), , Less Credit For Damaged And Dismantled Material Received From The Work :-, , 5/15/16 Amp. Switch/socket/bell Push/tv Antenna Socket/telephone Socket/dp Switch/fan Regulator (assorted), , Pvc in Delhi - Delhi

Tender Details
Reference # :
45690757
Description :
Tenders for A.r. &amp; Maintenance Of 196 Hmps Flats At South Avenue Under Sub Div-1 Of Ded-201, New Delhi. (sh: Replacement Of Defective Electrical Accessories I/c Supply Of Material).subwork/packages:replacement Of Defective Electrical Accessories I/c Supply Of Material. - Supplying, Installation, Testing &amp; Commissioning Of Flood Light, Powder Coated Pressure Die Cast Aluminium Body With Built In Or Separate Driver As Per The Requirement With Driver Efficiency >85%, Input Voltage : Input Voltage: 140-270 Volt Ac, Freq 50/60 Hz, Operating Temp Range - 5 Deg. To 50 Deg. Centigrade, Internal Surge Protection Of 5 Kv L,n,e As Per Iec 61000-4-5, Driver Efficiency >85%, Thd < 10% As Per Iec 61000-3-2, P. F.≥0.95, Ip-66, Ik-10, Cri >70, Under Voltage And Over Voltage Protection, Emiemc As Per Cispr -15, Lenses For Beam Angle 30 Deg- 120 Deg As Per The Application And The Project Requirement Deg., Suitable Tilt Able Fitting, Life Time (led, Driver &amp; Electrical Circuitry) Of Minimum 50000 Burning Hours With 70% Of Initial Lumen Maintained Till Life Ends As Per Lm80 Extrapolation Ies Tm-21-11 Report, Cct 3000°k/4000°k /5700°k /6500°k (as Per Ansi Bin), Sdcm(standard Deviation Color Matching) <5, Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Relevant Bis Standard Complete In All Respect I/c External Connections With 1.5 Sq Mm Frls/hffr, Pvc Insulated Copper Conductor Single Core Cable And Earthing Etc. As Required With Minimum 5 Year Oem Warranty. System Lumen Efficacy 105 <120 Lm/watt Output. Lm79 &amp; Lm80 Test Report And All Testing Required For Led Fixtures As Per Bis Shall Be Submitted.. Shape Size And Cct Shall Be As Approved By Engineer-in-charge As Per Requirement. (thermal Management: Heat Sink Of Aluminium Housing Such That Led Junction Temperature Shall Not Rise Above 90°c). (make: Havells/ Wipro/ Philips/ Crompton/ Regent) 1.1 50 Watt , 1.5 Sq Mm Frls Pvc Insulated Single Core Copper Conductor Cable., , 4 Sq Mm Frls Pvc Insulated Single Core Copper Conductor Cable., , 6 Sq Mm Frls Pvc Insulated Single Core Copper Conductor Cable., , S.p. 5/6 A, One Way Modular Switch, , S.p. 5/6 A, Two Way Modular Switch, , S.p. 15/16 A, One Way Modular Switch, , 3 Pin 5/6 A Modular Socket Outlet, , 6 Pin 15/16 A Modular Socket Outlet, , Modular Bell Push, , Stepped Type Modular Fan Regulator (2 Module), , Telephone Socket Outlet Modular Type, , T.v. Socket Outlet Modular Type, , Modular Blanking Plate, , Modular Base &amp; Cover Plate For 1 Or 2 Module, , Modular Base &amp; Cover Plate For 3 Module, Modular Base &amp; Cover Plate For 4 Module, , Modular Base &amp; Cover Plate For 6 Module, , Modular Base &amp; Cover Plate For 8 Module, , Modular Base &amp; Cover Plate For 12 Module, , Modular Gi Box For 2 Module, , Modular Gi Box For 3 Module, , Modular Gi Box For 4 Module, , Modular Gi Box For 6 Module, , Modular Gi Box For 8 Module, , Modular Gi Box For 12 Module, , 3 Pole Mccb, 125 A, 16ka, , 6 Amps. To 32 Amps. Ratings, Sp Mcb, "c" Curve, 10 Ka Breaking Capacity, , 40 Amps., 2 Pole Isolator, , 63 Amps., 2 Pole Isolator, , 100amp., 4 Pole Isolator, , Supply Of Led Batten Light (system Lumen Efficacy ≥105 <120 Lm/watt) Of Following Body Materials. Powder Coated Die Cast /extruded Aluminium Body (thickness > 1.20 Mm) (make: Havells/ Wipro/ Philips/crompton/regent), , 18-22 Watt, , 40 Watt, , Supply Of Led Down Lighter (smd Type) (system Lumen Efficacy ≥ 105 <120 Lm/watt) Of Following Body Materials. Powder Coated Die Cast/extruded Aluminium Body Including Trim With Aluminium Reflector (make: Havells/ Wipro/ Philips/ Crompton/regent), , 5-7 Watt, , 8-10 Watt, , 12-15 Watt, , Supply Of Led Bulb 9 Watt B-22/e- 27 Type (3 Star &amp; Above) (white/yellow Colour) (make: Havells/ Wipro/ Philips/ Crompton/regent), , Less Credit For Damaged And Dismantled Material Received From The Work :-, , 5/15/16 Amp. Switch/socket/bell Push/tv Antenna Socket/telephone Socket/dp Switch/fan Regulator (assorted), , Pvc
Ownership :
Sector :
Tender Values
Value :
578,280
EMD :
11,567
Doc. Cost :
NA
Important Dates
Due date :
02 Jul, 2026
Open date :
02 Jul, 2026
Publish date :
25 Jun, 2026
Location
Location :
Delhi - Delhi ( IN )
Connect us via What's Up