Web Analytics Made Easy - StatCounter

Tender for Repair/replacement Of External Electric Supply Distribution Network With Other Connected Items At Malad, Marve And Kandivali Under Ge (n) Santacruz, Mumbai - Supply, Install, Testing & Commissioning Pedestal Cubical Type Double Door Lt Bus Bar Chamber Box Of Suitable Size Factory Made Modular Construction Fabricated Out Of 3 Mm Thick Crca Sheet, Angle Iron, Channels, Epoxy Powder Coated To Give A Superior Finish , Outdoor Type , Totally Enclosed Dust & Vermin Proof With Locking Arrangements Front & Back Side Opening System Including Rain Shed, Busbar Chamber Should Be Suitable For Accomodating All Aluminium Bus Bar Strips (50mm X 10mm X 04 Nos) & Gi Strip For Earth Fixed On Porcelain Insulators, And One Independent Metering Module Suitable For Accomodating Three Phase Volt Meters & Ammeter Digital Type, Indicator Lamps, Cable Entry/exits Cut Outs At Bottom Part, With Fixing Arrangement On Pcc (1:3:6) Type C-2 Bed Block With Studs, Bolts, Nuts & Washers, Danger Notice Board With Scull Suitable For 415 Volts Or Required Size To Be Fixed On Pannel Including Dismantling Of Old Bus Bar Panel All As Specified And Directed By Engr-in Charge.notes:-(a) Aluminium Bus Bar Duly Covered With Colour Coded Shrinkable Sleeves Of Required Size For Phases And Neutral - 01 Set(b) Mccb 4 Pole , Ics=100%icu- 25 Ka, 415 Volts, 100 Amps , With Thermal Adjustable And Fixed Magnetic Setting With Extended Terminals -02 Nos.(c) Digital Multifunction Meter Of Size 96x96 Mm To Measure Current, Voltage, Frequency And Power Factor With Built In Selector Switch And Programable Ct Of Appropriate Ratio.-01 No Make- Imp/automatic Electrical(ae)/ L&t / Havells/ Meco(d) Panel Indicating Lamp Neon/led Type (red ,yellow & Blue) With Lamp Holders - 03 Nos(e) Panel Instrumental Wiring With Frls Suitable Size But Not Less Than 2.5 Sqmm Copper Wire Single Core - 01 Job(f) Necessary Sizes Of Lugs For Fixing Of Cables In Bus Bar Deemded To Be Included Rate Quoted By The Contractor.make Of Mccb & Mcb: Larsen &toubro/ Abb/ Siemens/ Schneider/ Havells/ Legrand/ Indo Asian/ C & S Electric/ Bhartia Cuttler Hammer (bch)/benlo, Supply & Fixing Mccb 4 Pole 36 Ka 400 Amp With Adjustable Thermal & Adjustable Magnetic Setting, Including Taking Down Old Unserviceable Mccb, All As Specified And Directed By Engr-in-charge. Make:- Larsen &toubro/ Abb/ Siemens/ Schneider/ Havells/ Legrand/ Indo Asian/ C & S Electric/ Bhartia Cuttler Hammer (bch)/benlo, Supply & Fixing Mccb 4 Pole 36 Ka 160 Amp With Adjustable Thermal & Adjustable Magnetic Setting, Including Taking Down Old Unserviceable Mccb, All As Specified And Directed By Engr-in-charge. Make:-larsen &toubro/ Abb/ Siemens/ Schneider/ Havells/ Legrand/ Indo Asian/ C & S Electric/ Bhartia Cuttler Hammer (bch)/benlo, Supply & Fixing Mccb 4 Pole 16 Ka 100 Amp With Adjustable Thermal & Adjustable Magnetic Setting, Including Taking Down Old Unserviceable Mccb, All As Specified And Directed By Engr-in-charge. Make:-larsen &toubro/ Abb/ Siemens/ Schneider/ Havells/ Legrand/ Indo Asian/ C & S Electric/ Bhartia Cuttler Hammer (bch)/benlo, Supply & Fixing Mccb 4 Pole 36 Ka 250 Amp With Adjustable Thermal & Adjustable Magnetic Setting, Including Taking Down Old Unserviceable Mccb All As Specified And Directed By Engr-in-charge Make:-larsen &toubro/ Abb/ Siemens/ Schneider/ Havells/ Legrand/ Indo Asian/ C & S Electric/ Bhartia Cuttler Hammer (bch)/benlo, Supplying, Laying,connecting, Testing & Commissioning Lt Ug Pvc Insulated, Heavy Duty, 1100 V Grade Electric Cable With Aluminium Conductor Of Size 16 Sqmm X 4 Core, Laid In Trenches Or Passing Through Pipe Or Fixed To Wall, Making All Connections With And Including Provision Of Necessary Glands, Lugs, Bushing Etc As Required Including Taking Down Old Unserviceable Cable Complete All As Specified And As Directed By Engineer-in-charge Of Following Sizes:-note : Earthwork Excavation, Dwc in Mumbai - Maharashtra

Tender Details
Reference # :
45713835
Description :
Tenders for Repair/replacement Of External Electric Supply Distribution Network With Other Connected Items At Malad, Marve And Kandivali Under Ge (n) Santacruz, Mumbai - Supply, Install, Testing & Commissioning Pedestal Cubical Type Double Door Lt Bus Bar Chamber Box Of Suitable Size Factory Made Modular Construction Fabricated Out Of 3 Mm Thick Crca Sheet, Angle Iron, Channels, Epoxy Powder Coated To Give A Superior Finish , Outdoor Type , Totally Enclosed Dust & Vermin Proof With Locking Arrangements Front & Back Side Opening System Including Rain Shed, Busbar Chamber Should Be Suitable For Accomodating All Aluminium Bus Bar Strips (50mm X 10mm X 04 Nos) & Gi Strip For Earth Fixed On Porcelain Insulators, And One Independent Metering Module Suitable For Accomodating Three Phase Volt Meters & Ammeter Digital Type, Indicator Lamps, Cable Entry/exits Cut Outs At Bottom Part, With Fixing Arrangement On Pcc (1:3:6) Type C-2 Bed Block With Studs, Bolts, Nuts & Washers, Danger Notice Board With Scull Suitable For 415 Volts Or Required Size To Be Fixed On Pannel Including Dismantling Of Old Bus Bar Panel All As Specified And Directed By Engr-in Charge.notes:-(a) Aluminium Bus Bar Duly Covered With Colour Coded Shrinkable Sleeves Of Required Size For Phases And Neutral - 01 Set(b) Mccb 4 Pole , Ics=100%icu- 25 Ka, 415 Volts, 100 Amps , With Thermal Adjustable And Fixed Magnetic Setting With Extended Terminals -02 Nos.(c) Digital Multifunction Meter Of Size 96x96 Mm To Measure Current, Voltage, Frequency And Power Factor With Built In Selector Switch And Programable Ct Of Appropriate Ratio.-01 No Make- Imp/automatic Electrical(ae)/ L&t / Havells/ Meco(d) Panel Indicating Lamp Neon/led Type (red ,yellow & Blue) With Lamp Holders - 03 Nos(e) Panel Instrumental Wiring With Frls Suitable Size But Not Less Than 2.5 Sqmm Copper Wire Single Core - 01 Job(f) Necessary Sizes Of Lugs For Fixing Of Cables In Bus Bar Deemded To Be Included Rate Quoted By The Contractor.make Of Mccb & Mcb: Larsen &toubro/ Abb/ Siemens/ Schneider/ Havells/ Legrand/ Indo Asian/ C & S Electric/ Bhartia Cuttler Hammer (bch)/benlo, Supply & Fixing Mccb 4 Pole 36 Ka 400 Amp With Adjustable Thermal & Adjustable Magnetic Setting, Including Taking Down Old Unserviceable Mccb, All As Specified And Directed By Engr-in-charge. Make:- Larsen &toubro/ Abb/ Siemens/ Schneider/ Havells/ Legrand/ Indo Asian/ C & S Electric/ Bhartia Cuttler Hammer (bch)/benlo, Supply & Fixing Mccb 4 Pole 36 Ka 160 Amp With Adjustable Thermal & Adjustable Magnetic Setting, Including Taking Down Old Unserviceable Mccb, All As Specified And Directed By Engr-in-charge. Make:-larsen &toubro/ Abb/ Siemens/ Schneider/ Havells/ Legrand/ Indo Asian/ C & S Electric/ Bhartia Cuttler Hammer (bch)/benlo, Supply & Fixing Mccb 4 Pole 16 Ka 100 Amp With Adjustable Thermal & Adjustable Magnetic Setting, Including Taking Down Old Unserviceable Mccb, All As Specified And Directed By Engr-in-charge. Make:-larsen &toubro/ Abb/ Siemens/ Schneider/ Havells/ Legrand/ Indo Asian/ C & S Electric/ Bhartia Cuttler Hammer (bch)/benlo, Supply & Fixing Mccb 4 Pole 36 Ka 250 Amp With Adjustable Thermal & Adjustable Magnetic Setting, Including Taking Down Old Unserviceable Mccb All As Specified And Directed By Engr-in-charge Make:-larsen &toubro/ Abb/ Siemens/ Schneider/ Havells/ Legrand/ Indo Asian/ C & S Electric/ Bhartia Cuttler Hammer (bch)/benlo, Supplying, Laying,connecting, Testing & Commissioning Lt Ug Pvc Insulated, Heavy Duty, 1100 V Grade Electric Cable With Aluminium Conductor Of Size 16 Sqmm X 4 Core, Laid In Trenches Or Passing Through Pipe Or Fixed To Wall, Making All Connections With And Including Provision Of Necessary Glands, Lugs, Bushing Etc As Required Including Taking Down Old Unserviceable Cable Complete All As Specified And As Directed By Engineer-in-charge Of Following Sizes:-note : Earthwork Excavation, Dwc
Ownership :
Sector :
Tender Values
Value :
3,000,000
EMD :
60,000
Doc. Cost :
500
Important Dates
Due date :
18 Jul, 2026
Open date :
20 Jul, 2026
Publish date :
27 Jun, 2026
Location
Location :
Mumbai - Maharashtra ( IN )
Connect us via What's Up