Tender For damaged and replacement ht/lt pole & lines, ab line against daiveey aapda under electricity distribution division maharajganj raebareli. approx. distance upto 40 km. including safe loading and unloading.
Tender For for the work for strengthening of damaged 33 and 11 kv ht/lt line and other related works due to heavy rain/accident/storm and other reasons under edd-bisauli in m & r head against running contract 2026-27.
Tender For annual maintenance of outdoor vcb installed at the 33 kv sub stations under the jurisdiction of amusi zone lucknow against in anticipation of acceptance o&m 2026-27.
Tender For supply of various materials required for the daily up- keep and maintenance work of 33/11 kv substations under the jurisdiction of amusi zone ,mvvnl lucknow. - aluminium crimping lugs long verrel (made of 99.9% pure a grade alumunium suitable for 240 sqmm cable weight 78 gram (permissible tolerancle limit +/-5%), aluminium crimping lugs long verrel (made of 99.9% pure a grade alumunium suitable for 400 sqmm cable weight 170 gram (permissible tolerancle limit +/-5%), aluminium crimping lugs long verrel (made of 99.9% pure a grade alumunium suitable for 630 sqmm cable weight 298 gram (permissible tolerancle limit +/-5%), brass back entry 300 amp 650 volt (flate type) made of brass with g.i. nut suitable for henley type tailles fuse unit (overall weight 0.26 kg) (permissible tolerancle limit +/-5%), brass back entry 500 amp 650 volt (flate type) made of brass with g.i. nut suitable for henley type tailles fuse unit (overall weight 0.4 kg) (permissible tolerancle limit +/-5%), u-type spring contact 300 amp. 650 volt made of electric strip strip of size 32x4mm weight 325 gram sutable for 300 amp. henlay type tailless fuse unit (permissible tolerancle limit +/-5%), u-type spring contact 500 amp. 650 volt made of electric strip strip of size 45x5mm weight 500 gram sutable for 500 amp. henlay type tailless fuse unit (permissible tolerancle limit +/-5%), copper l-piece sutable for 250/400 kva t/f of size 125x75x50x6 mm made of electrolytic copper strip 99.9% purity., copper l-piece suitable for 630 kva t/f of size 150x100x65x8 mm made of electrolytic copper strip 99.9% purity., copper l-piece suitable for 1000 kva t/f of size 225x150x75x10 mm made of electrolytic copper strip 99.9% purity., henely type tailless unit 500 amp. 650 volts consisting of 6 nos brass back entry, 6 nos. u-type spring contact made of copper, brass coupling with porcelain fitted on the gi sheet of 16 swg with arrangement of one no. neutral., henely type tailless unit 300 amp. 650 volts consisting of 6 nos brass back entry, 6 nos. u-type spring contact made of copper, brass coupling with porcelain fitted on the gi sheet of 16 swg with arrangement of one no. neutral., l.t. bushing rod complete with nuts, conical washer with housing 250/400 kva t/f size 16x260 mm complete., l.t. bushing rod suitable for 630 kva distributions t/f of size 25x260 mm complete., l.t. bushing rod suitable for 1000 kva distributions t/f of size 42x350 mm complete., brass coupling 300 amp. made of brass suitable for 300 amp. henley type tailless fuse unit., brass coupling 500 amp. made of brass suitable for 500 amp. henley type tailless fuse unit., porcelain 300 amp. o/g type with caller suitable for 300 amp. henely type tailles fuse unit., porcelain 500 amp. o/g type with caller suitable for 500 amp. henely type tailles fuse unit., conical washer for 250/400 kva lt bushing rod., conical washer for 630 kva lt bushing., conical washer for 1000 kva lt bushing rod., nuprence bonded rubberised cork sheet packing suitable for lt bushing of 250/400kva t/f, nuprence bonded rubberised cork sheet packing suitable for lt bushing of 630kva t/f, nuprence bonded rubberised cork sheet packing suitable for lt bushing of 1000kva t/f, rewirable type tinned copper fuse wire of size 8 swg confirming of is:9936 or latest version thereof., rewirable type tinned copper fuse wire of size 10 swg confirming of is:9936 or latest version thereof., rewirable type tinned copper fuse wire of size 18 swg confirming of is:9936 or latest version thereof., rewirable type tinned copper fuse wire of size 22 swg confirming of is:9936 or latest version thereof., rewirable type tinned copper fuse wire of size 24 swg confirming of is:9936 or latest version thereof., copper bus bar of size 1000x50x6 mm made of electrolytic copper strip., l-piece for henley type tailless fuse unit., pg clamp for panther to panther conductor, pg clamp for dog to dog conductor, good quality bamboo ladder 30 fit, good quality bamboo ladder 32 fit, ru
Tender For for the work for strengthening of damaged 33 and 11 kv ht/lt line and other related works due to heavy rain/accident/storm and other reasons under edd-ujhani in m & r head against running contract 2026-27.
Tender For repairing of existing damage plinth of 11/0.4 kv sub stations at various places in the area of edsd-i madhuban & edsd-ii gora bazar under the juridiction of electricity distribution division raebareli.
Tender For installation of additional distribution transformers with capacities of 10 kva and 16 kva within the jurisdiction of the nighasan electricity distribution division, under the business plan 2025-26.
Tender For annual maintenance of 11 kv css installed at the 33/11 kv sub stations under the jurisdiction of amausi zone lucknow against in anticipation of acceptance o&m 2026-27.