Web Analytics Made Easy - StatCounter

Municipal Corporation Of Greater Mumbai Tenders - MCGM Tenders

Get complete information related to latest Municipal Corporation Of Greater Mumbai Tenders - MCGM Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Municipal Corporation Of Greater Mumbai Tenders - MCGM Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Municipal Corporation Of Greater Mumbai Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :42056710 Due date: 01 Dec, 202501 Dec, 2025 NA
Tender For corrigendum : manning, operating and maintaining life guard services for zone vii beaches in mumbai under mumbai fire brigade bmc for 3 years - manning, operating and maintaining life guard services for zone vii beaches in mumbai under mumbai fire brigade bmc for 3 years with equipments

CTN :42056725 Due date: 01 Dec, 202501 Dec, 2025 NA
Tender For corrigendum : manning, operating and maintaining life guard services for zone iii and zone iv beaches in mumbai under mumbai fire brigade bmc for 3 years.

CTN :42056735 Due date: 01 Dec, 202501 Dec, 2025 NA
Tender For corrigendum : manning, operating and maintaining life guard services for zone i and zone ii beaches in mumbai under mumbai fire brigade bmc for 3 years

CTN :42535123 Due date: 01 Dec, 202501 Dec, 2025 NA
Tender For corrigendum : supply, installation, testing and commissioning of arthroscopic rf plasma system(1 no.) along with standard accessories and cmc for 7 years after the completion of warranty of three years for use of orthopedic of smt. m.t. agarwal mun. gen. hospital, mulund (w)

CTN :42535124 Due date: 01 Dec, 202501 Dec, 2025 NA
Tender For corrigendum : supply, installation, testing and commissioning of autorefractometer (1 no.) along with standard accessories and cmc for seven years after the completion of warranty of three years for use of ophthalmic department of smt. m.t. agarwal mun. gen. hospital, mulund (w)

CTN :42498816 Due date: 03 Dec, 202503 Dec, 2025 NA
Tender For corrigendum : supply, installation, testing and commissioning of additional pump sets with allied works at kajupada pumping station in r c ward under aewwmwsn ii division

CTN :42578787 Due date: 25 Nov, 202525 Nov, 2025 NA
Tender For corrigendum : isopropyl alcohol 99 percent

CTN :42517918 Due date: 26 Nov, 202526 Nov, 2025 NA
Tender For corrigendum : inj. gadolinium based constrast for mri for liver/liver specific

CTN :42579205 Due date: 05 Dec, 202505 Dec, 2025 NA
Tender For corrigendum : supply of schedule iv (x-ray films, chemicals, e. c. g. rolls, materiels etc.) - schedule iv (x-ray films, chemicals, e. c. g. rolls, materiels etc.), polyster base round corner x-ray films (8" x 10") green sensitive, blue base with base fog less than or equal to 0.23 & dmax not less than 3.10 interleaved. the density values should be met at developer temperature 32 c to 35 c, polyster base round corner x-ray films (10" x 12") green sensitive, blue base with base fog less than or equal to 0.23 & dmax not less than 3.10 interleaved. the density values should be met at developer temperature 32 c to 35 c, polyster base round corner x-ray films (12" x 15") green sensitive, blue base with base fog less than or equal to 0.23 & dmax not less than 3.10 interleaved. the density values should be met at developer temperature 32 c to 35 c, dental x-ray films intraoral periapcal the density values should blue base with base fog less than or equal to 0.20 & dmax not less than 3.10 the density values should be met at developer temperature 32 c to 35 c, liquid developer replenisher for automatic processor (starter solution, if recommended by the manufacturer, should also be supplied), ( price of item no. 5 and item no. 6 will be considered as a unit), liquid fixer hardner for automatic processor ( price of item no. 5 and item no. 6 will be considered as a unit), inj. meglumine diatrizoate sodium diatrizoate iodine content 365-375 mg/ml in 20 ml. ampoule/vial, pigtail angiography catheter with multiple side holes length 65 to 75 cm 5f, inj. gadolinium based contrast for mri for liver/liver specific (should provide details of compound being hepatobiliary specific), inj. gadolinium based contrast for mri for general use, inj. gadolinium based contrast for mri for angiography, disp lure lock syringes 3 ml. for glue injection, disp lure lock syringes 1 ml. for glue injection, x-ray folders laminated 250 gsm 14 1/2" x 17 ", dual pack 200 ml syringe with aspirator, "y" shaped coiled tube y-tube sterile, non-pyrogenic (minimum 300 psi & above) compatible with dual head pressure injector ( lf/medrad/ sea crown / spectra / apollo), extension "y" shaped coiled tubing for injector 150 cms. (-5 or +15cm) low pressure (minimum 300 psi & above), dual disposable syringes (60 to 65 ml each) with "y" or "t"shaped coiled tube connecting tubes small spike for contrast and large spike for saline compatible with mri injector (lf or medrad)., one way stopcock (high pressure), low pressure extension "y" or "t" shaped coiled tubing min. 150cms (-5 or +15 cms) with coiled connecting tubes & small spike for contrast & large spike for saline for medical mri injector., flavoured, ionic, water soluble, oral contrast iodine content 240-250 mg/ ml. in 30 ml, bernstein catheter 4 f 100 cm, bernstein catheter 5 f 100 cm, chiba needle 21 g 15 cms length, chiba needle 22 g 15 cms length, disposable c t scan pressure injector syringes (190 ml syringe + quick fill tube) for bayer medrad salient injector (toshiba / canon), extension "y" shaped coild tube adapter dual check valves (minimum psi 300 & above), nonionic iodixanol isoosmolar, 320 mg 50 ml, disposable mri syringes kit for 65/115 mr injector system 65 ml contrast syringes and 115 ml ns syringes with connecting tubing combo pack for spectris solaris medrad pressure injector, spring loaded fully automatic and semi automatic biopsy instrument with adjustable penetration depth of 18 mm and 25 mm. having trocar tip with dimpling on needle and fire ready indicator. 14 g & 10 cm in length, spring loaded fully automatic and semi automatic biopsy instrument with adjustable penetration depth of 18 mm and 25 mm. having trocar tip with dimpling on needle and fire ready indicator. 16 g & 10 cm in length, coil shape breast tissue marker with both front trigger & an alternate rear trigger, should be visible in ultrasound, mammography and mri, extension coiled tube with integr

CTN :42579207 Due date: 05 Dec, 202505 Dec, 2025 NA
Tender For corrigendum : supply of sch viii (supply of needle & syringes) - sch viii (supply of needle & syringes), disposable needle sterile length 1/2" guage 25, suture needle, half circle triangular nos. 2 to 20 (cutting), insulated needle for use with peripheral nerve stimulator 22g x 2" x 50 mm., insulated needle for use with peripheral nerve stimulator 22g x 35 mm., insulated needle for use with peripheral nerve stimulator 24g x 1"x 25 mm., echogent needles for usg guided peripheral nerve blocks 20g / 21g x 100 mm., echogent needles for usg guided peripheral nerve blocks 22g x 50 mm., epidural needles 16 & 18 guage 7.5cm to 11cm (disposable), epidural needles (long length) 18g (more than 100 mm. length), sterile disposable lancet size 28-32 (plastic lancet needle type), sterile disposable hypodermic plastic syringe 20cc, cn. with leur lock, hypodermic syringes,disposable sterile, sterile pack,with/without leur lock, hub 1ml syringe with marking at 0.1 ml, asepto syringe 100 ml of heavy plastic barrel and rubber bulb with marking., bag arm rubber with cover for b.p. apparatus, adult size velcro.rubber bag size 13 x 23 cms., keratome, size 2.8 mm, type-regular(ophthalmic), angle-45 degrees, bevel type- bevel up (pointed)blade-stainless steel/carbon steel,handle- polycarbonate, use- disposable single use, mvr, gauge 23g type-regular(ophthalmic), blade-stainless steel handle- polycarbonate, use- single disposable use, triple lumen catheter 7.5fr with 14g distal lumen, length-15cm. kit contain 1 teflon-coated j nitinol guidewire particularly kink-resistant with guide-advancer. 1 dilator, 10cm long, 3 injection caps, 3 clamps,1 supplementary fixation wing,1 scalpel, 1 syringe 5 ml, 1 adaptor for pressure transducer, 1 puncture needle 18g, 70mm long with a pre-connected valve to aviod air embolism and blood loss, 18g short iv cannula, double lumen subclavian/ jugular catheter kit (adult) ptfe (teflon) cannula curved od 2.7/d 11.5fr-12fr/chx5.3in. (3.8 mm x 13.5 cm) 6 side holes silicon tube s clamping extension, clamp luer lock "y" connector with protective caps size 12.5, 15 with guide wire introducer needle, dialator , 3fr double lumen cvc catheter with 60mm double-lumen polyurethane central venous catheter inserted by seldinger technique, radio opaque material for catheter, the user should be able to choose from 2 type of introducer, i.e.needle 23g or i.v. cannula 22g, latex free, the central venous catheter set should contain: 1 double-lumen polyurethane 3fr catheter, 1 short i.v. cannula 22g, 1 introducer needle 23g, 1 kink resistant guidewire with soft flexible tip, dilator with cylindrical /pencil point tip, 1 secondary fixation wing, 2 injection caps, 1 scalpel, 1.5 ml syringe, peripherally placed radiopaque central single lumen catheter. guage 14/16 (100%) (needles size/catheter size) length - 55cm - 70cm, peripherally placed radiopaque central single lumen catheter. guage 18/20 (100%) (needles size/catheter size) length 30cm - 45cm, fully radiopaque pur catheter 16g for femoral artery centimeter marking from 5-15cm, winged hub for skin fixation, supple distal tip. kit should contain 1 pur catheter with xro lines,1 puncture needle, 1 j guidewire with wishbone-type guidewire advancer, 1 dilator, radial/femoral arterial pe catheter with antikinking collar & fixation wings,straight guide wire, introducer needle.catherter size g- 18, length 10cm, radial/femoral arterial pe catheter 20g, 8cm puncture needle is fitted with a visualization chamber allowing to confirm that the vessel punctured is an artery (pulsatile movement of the blood). the needle is also fitted with a silicone bloodless system valve to avoid loss of blood during vessel puncture and a funnel hub to facilitate the insertion of the guidewire, peripherally inserted central catheter with guide wire with peelable cannula, made of polyurethane, non-toxic, with radio opaque line throughout the catheter with marking every cm with leur connector at proximal en
 Loading, Please wait...

Connect us via What's Up