Tender For tender for re-conducting of lt line from existing. 11/0.4 kv, 100 kva s/stn sokni da kot and 11/0.4 kv, 250 kva s/stn tts with aaac conductor 7/3.15 mm2 and strength with additional s/t pole at es khaniyra uesd sidhpur
Tender For dismantling and erection of 5 span wolf conductor of 11kv overhead line of feeder 1and 2 near pb area office which is damaged at many places under kusunda area
Tender For replacement of acsr weasel conductor to aaac covered conductor from 33/11 kv substation kamaluaganja to 11kv mukhani under electricity distribution division (rural) haldwani.
Tender For replacement of acsr weasel conductor to aaac covered conductor from 33/11 kv substation kamaluaganja to 11kv mukhani under electricity distribution division (rural) haldwani.
Tender For establishing 2x160mva, 220/110 kv & 1x10 mva, 110/11kv sub-station at hunagund (amaravathi) by construction of 220kv dc line from proposed 400kv kushtagi sub-station to the proposed 220/110kv hunagund sub-station for a distance of 36.745 kms using aaac moose conductor and construction of 220kv lilo line from 220kv balkundi-marol lis sc line (connecting 220kv balakundi lis & 220kv marol lis radially from proposed 220/110kv hungund sub-station) for a distance of 7.248 kms using drake conductor along with construction of 2 nos. of 220kv tbs at ongoing 400kv kushtagi sub-station. also, construction of 110kv dc lilo line from existing 110kv hungund-ilkal dc line to proposed 220kv hungund (amaravathi village) sub-station for a distance of 6.958 kms using lynx conductor in hungund taluk , bagalkot district.
Tender For maintenance- repairs- replacement of electrical items for various projects executed under srinagar smart city limited for a period of 2 years. - supply, installation, testing, commissioning including loading, transportation, insurance, unloading, carriage, delivery and erection of following sizes of distribution transformer at site., i) 630 kva distribution transformer, ii) 400 kva distribution transformer, iii) 250 kva distribution transformer, iv) 100 kva distribution transformer, v) 63 kva distribution transformer, fixing of fabricated gi angle/channel/flat/pole collars., fixing of galvanised nuts and bolts., supply, installation, testing, commissioning, insurance, unloading, carriage and delivery at site, laying, stringing and binding of conductor including joints with pg clamps of required following size of acsr conductor (0.1 /0.05/ 0.03), i) 100 sqmm acsr (dog), ii) 50 sqmm acsr (rabbit), iii) 30 sqmm acsr (weasel), supply, installation, testing, commissioning of ab (ht) cable of following sizes:, iii) 50 mm ab (ht) cable (3x50+1x70 mm ) xlpe(11 kv, 3c +earth), iv) 70 mm ab (ht) cable (3x70+1x95 mm ) xlpe(11 kv, 3c +earth), v) 95 mm ab (ht) cable (3x95+1x95 mm ) xlpe(11 kv, 3c +earth), vi) 120 mm ab (ht) cable (3x120+1x95 mm ) xlpe(11 kv, 3c +earth), mid span straight through jointing kit for 11 kv abc of following sizes:, i) 11 kv abc 50-95mm straight through jointing kit (3 core), ii) 11 kv abc 120-185mm straight through jointing kit (3 core), iii) 11 kv abc 240-300mm straight through jointing kit (3 core), heat shrinkable outdoor cable termination kit for ht/lt abc of following sizes:, i) 11 kv abc 70-95 mm outdoor cable termination kit, ii) 11 kv abc 120 mm outdoor cable termination kit, iii) 11 kv abc 150-185 mm outdoor cable termination kit, iv) 11 kv abc 240-300 mm outdoor cable termination kit, supply, installation, testing, commissioning of ab (lt) cable of following sizes:, ii) 50 mm ab (lt) cable ( 3x50 + 1 x 16 + 1 x 35) mm xlpe (1.1kv, 3+1 c, al), iii) 70 mm ab (lt) cable (3 x 70 + 1 x 16 + 1 x 50) mm xlpe (1.1kv, 3+1 c, al), iv) 120 mm ab (lt) cable (3 x 120 + 1 x 25 + 1 x 95) mm xlpe (1.1kv, 3+1 c, al), straight through cable jointing kit for lt abc of following sizes:, ii) 50 mm ab (lt)straight through cable jointing kit, iii) 70 mm ab (lt)straight through cable jointing kit, iii) 120 mm ab (lt)straight through cable jointing kit, dismantling, i) dismantling, stacking of 9/8 mtr st poles and transportation back to divisional store as per the instruction of electrical incharge., ii) dismantling of 0.03/0.05/0.1 acsr conductor and transportation to divisional stores (servicible), servo voltage stabilizer, i) supply, installation, testing, commissioning including loading, transportation, insurance, unloading, carriage and delivery at site and erection of 63 kva, 3-phase oil cooled servo (complete job), ii) supply, installation, testing, commissioning including loading, transportation, insurance, unloading, carriage and delivery at site and erection of 50 kva, 3-phase oil cooled servo (complete job), rmu, supply, installation, testing, commissioning including loading, transportation, insurance, unloading, carriage and delivery at site and erection of 4 way type,two isolators and two circuit breakers 11 kv, ring main unit ,sf6 insulated, out-door type, extensible type,breaking capacity 25 ka for one second with sf6 circuit breaker / vcb self powered with o/c + e/f relay comprising of a) 11kv 630 amp motorised isolator including earthing switches with making capacity 52ka, having mechanical on/off, earth indications with fault current indicator.b) 11kv ,400 amp motorised spring operated, circuit breakers with earthing switches, connecting the rmu to supply transformer. c). copper bus bar of 630 amp rating.d). 1 no numerical aux. powered relay having non directional o/c and e/f protection (for each ciruit breaker).d). the circuit breaker enclosures shall be outfitted with a communicable-type numerical (feeder p
Tender For corrigendum : part-a- establishing 2x150 mva, 2x31.5 mva, 220/66/11kv sub-station at adinarayana hosahalli phase-ii industrial area at doddaballapura taluk, bengaluru rural district, part-b- running of 220kv dc 1200sqmm xlpe copper ug cable from 220/66kv doddaballapura (nrs) station to proposed 220kv cable terminating tower near adinarayana hosahalli phase-2 i/a entry point for distance of 5.435 kms., part-c- construction of 220kv transmission line using dc & mc design based monopoles from i/a entry point (proposed 220kv ctt) and from proposed 400/220kv adinarayana hosahalli i.a. s/s to proposed 220/66/11kv adinarayana hosahalli phase-2 kiadb s/s for a distance of 4.053 kms using aaac moose conductor, part-d- construction of 2 numbers of 220kv outdoor gis terminal bays at existing 220/66kv nrs doddaballapura station, part-e- construction of 2 numbers of 220kv indoor gis terminal bays at proposed 400/220kv adinarayana hosahalli station, part-f- 66kv lilo arrangement of existing 66kv nrs doddaballapura - vijayapura sc line to proposed 220/66/11kv adinarayana hosahalli phase - 2 kiadb sub-station under self execution basis by kiadb