Tender For corrigendum : part-a- establishing 2x150 mva, 2x31.5 mva, 220/66/11kv sub-station at adinarayana hosahalli phase-ii industrial area at doddaballapura taluk, bengaluru rural district, part-b- running of 220kv dc 1200sqmm xlpe copper ug cable from 220/66kv doddaballapura (nrs) station to proposed 220kv cable terminating tower near adinarayana hosahalli phase-2 i/a entry point for distance of 5.435 kms., part-c- construction of 220kv transmission line using dc & mc design based monopoles from i/a entry point (proposed 220kv ctt) and from proposed 400/220kv adinarayana hosahalli i.a. s/s to proposed 220/66/11kv adinarayana hosahalli phase-2 kiadb s/s for a distance of 4.053 kms using aaac moose conductor, part-d- construction of 2 numbers of 220kv outdoor gis terminal bays at existing 220/66kv nrs doddaballapura station, part-e- construction of 2 numbers of 220kv indoor gis terminal bays at proposed 400/220kv adinarayana hosahalli station, part-f- 66kv lilo arrangement of existing 66kv nrs doddaballapura - vijayapura sc line to proposed 220/66/11kv adinarayana hosahalli phase - 2 kiadb sub-station under self execution basis by kiadb
Tender For supply of xlpe cable for working voltages up to and including 1. 1 kv as per is 7098 (part 1) (q2) , pvc flat cable, copper conductor with pvc insulation and sheath as per is 694 (q3)
Tender For corrigendum : supply of sitc of auditorium in national media centre pib c c - 200w led cct tuneable fresnel light having cob led source , 300w led profile spot 19 degree light having cob led source , aluminium o type clamp provided with fixture mounting 25mm m8 bolt and wing nut , dual safety chain made of gi wire bundled and twisted together , ms sheet electrical panel with 7 outgoing circuits , high quality power junction box having total max rating 10a, 250v a.c with 350meter frls copper 3 core cable , metal power junction box 2 way snap fit , high quality dimming in junction box 1 way , high quality dimming out junction box 1 way , dmx loop junction box having 1 no. of dmx 5 pin xlr , internal earthing system with copper bare conductors all along the cable trays , black powder coated cable trays , dmx male female connectors 5 pin with rubber sheath protection with 300 meter cable , dmx male termination connector 5 pin with resistor for signal defaming , dmxcontroller 12 faders with dmx 512 protocol , opto isolated rdm enabled dmx splitter unit , table top microphone with 600mm gooseneck microphone, supercardoid lobar , digital mixing console and ipad control , modular card based digital signal processor , 2-way high power loudspeaker , ptz auto framing camera with ai analytics , live switcher with 4 standards converted 3g-sdi inputs, 2d dve , sdi to usb for media converter , large format display fullhd , camera preview full hd led screen , motorized retractable mic and monitor , one eighth hdmi distributor , hdmi transmitter and receiver , 8 by 8 hdmi swticher , sdi cable and connerctor , central controller with touch panel , digital interactive podium , phonoconnectors , dismentling of existing cables and connectors , complete sitc of auditorium , system operator for av system, lighting etc for 3 years, 3 operator ) /bid number : gem/2025/b/6856971 * /dated: 20-11-2025 & & / bid document 1 / 30
Tender For 04 no. esst. (for mid span pole and augmentation of aaac weasel conductor by aaac rabbit conductor and replacement of theft conductor under jhundpura d/c (oandm) division sabalgarh
Tender For corrigendum : supply,installation,testing commissioning of new 11 kv lines, lt line on ab cable, conversion of bare conductor to lt ab cable,dtr s/s and supporting works for separation of 11 kv mix feeders and dtrs fsp lot-vi harda circle mpmkvvcl, bhopal (rdss)
Tender For corrigendum : supply,installation,testing commissioning of new 11 kv lines, lt line on ab cable, conversion of bare conductor to lt ab cable,dtr s/s and supporting works for separation of 11 kv mix feeders and dtrs fsp lot- vii bhind circle mpmkvvcl, bhopal (rdss)
Tender For dcw estimate for shifting of existing ht/lt poles and line and 1 no e 52 - 100/22kv dt structure at 22kv north beach road feeder as per request of thiru.. mathan, tuticorin in beachroad section 2.name of the work: eos to 1 no tf -v cl 35 kw to tpkn. uravinmurai, 346,wgc road titicorin newly proposed 200/22kv single pole dt with plinth and bifurcation of load at e 19 500kva /22kv dt area of beach road section3.name of the work: imp etimate for replacement of existing aged conductor acsr 7/2.59, 7/2.50 aaac srengthening into aaac 7/3.15 at k 61 dt area (ambedkar nagar) in statebank colony tuticorin section4.name of the work : eos to 1 no indl service to sri ranganathar sirpa kalaikudam sf 148/1a, kurukkusalai road, k.shunmugapuram newly proposed 63/11kv dt in rural north section5.name of the work : eos to 1 no tysy sc to thiru. sankar singh , sf no.180,/4n, athiparasaktghi, tuticorin k43, 200/22kv dt area in statebank colony section6.name of the work : eos to 1 no tysy sc to thiru. muthukesavan, 275/3a2c, melamaruthur tuticorin at arasady ss 29, 40kva/22kv in rural north section7.name of the work : imp estimate for replacement of 3 nos damaged 8 mtr psc pole fallen due to natural calamities (heavy wind) by new pole at kalavasal ss 4 dt in rural north section
Tender For supply of 4500nos of stay set complete - supply of silicagel blue, 0.6kva ups, stay set complete( quote price for single unit only), silicagel blue 10 to 12mm, pole pit for 9.0m and 9.14 m psc/rcc / all metal poles (each pit) 1.25 x 0.6 x 1.83 mtr, ordinary soil, semi rocky soil, heavy rocky soil where blasting/ cheseling required [specific approval should be obtained from concerned ee], stay pit, in ordinary soil [0.95 x 0.6 x 1.2m], semi rocky soil, stay pit in heavy rocky soil where blasting/ cheseling reqiured [specific approval should be obtained from concerned ee], erection of poles & stays (including refilling of excavated earth), erection of 7.5m / 8.0m poles [rcc / psc], erection of 9.00m / 9.14m rcc / psc/rail pole, tubular pole and all metal poles, stay set, erection stay set complete, stay erection without rod and pit, replacement of stay rod only. (including stay pit excavation & refilling & erection), replacement of guy shackle only in existing stay, erection of line materials, fixing of lt 1 ph "x" arm, fixing of lt/ht ti fitting, fixing of lt 3 ph "x" arm, fixing of 3[1/2] v ` x arm, fixing of 4[1/2] v ` x arm, fixing of 5 v x arm, fixing of tapping channel / guarding "x" arm, providing of line spacers in lt lines 1 phase, providing of line spacers in lt lines 3 phase, erection of ab switch with pt insulator & jumpering complete, erection of centre rotating switch ab switch complete, fixing of ht pin insulator / strain disc, 11 kv pin insulator with pin, 11 kv strain disc / polymer disc with hardware, 22 kv pin insulator with pin, 22 kv strain disc / polymer disc with hardware, 33 kv pin insulator with pin, 33 kv pin strain disc/polymer disc with hardware, fixing of lt pin insulator with pin, lt shakle with hardware, fixing of aluminium knob, paving stringing and sagging of conductor including binding of pin and proper tight [including transport of condutor from road side to work spot] per run, upto 7/2.59 mm acsr, 7/2.50 aaac including pvc cable upto 25 sqmm, acsr 7/3.35mm & 7/ 3.15 aaac including pvc cable above 25 sqmm, acsr 7/4.09 mm, above 7/4.09 mm acsr & dog conductor, earthing wiring and connection including transporting of earth pipe and excavation of pit], transformer structure earthing 10ft depth - 3 nos of pipe through tubes, dp earthing including all works [double side earthing], erection of 4th earth pipe including earthing, earthing of poles, earth pit masonary work 3 nos earth pits or using 3 nos concrete tub., replacement of detoriated earth pipe per location, concreting with mixture 1:3:6 [including all materials]., mass concreting for centre support for 2 feet including all materials, mass concreting for pole0.6x0.6x1.25m.with coping, sleeve concreting for pole 0.6 m x 0.6m x 0.3 m with coping, sleeve concreting for stay set 0.3 m & 0.75 long, erection of distribution transformer structure complete, excavation of structure pole pits 0.9 x 0.9 x 1.83 mtr, transporting of pole to pit location 2 nos., erection of poles 2 nos, excavation of stay pit 4 nos, erection of stay set (4 sets), mass concreting (cement:sand:jelly supplied by the contractor) 2 nos., erection of 22 kv ab switch, ttransformer structure earthing 10ft depth - 3 nos of pipe through earth tubes, erection of top channel, bed channel [2 nos channel] erection, cross with stud for bed channel erection, erection of belting angle / hg fuse angle, erection of hg fuse set, erection of ht las with jumpering and earthing, erection of lt las with jumbering and earthing, erection of jumpering [ht side], transformer wiring in lt side including jumpering bus bar etc., erection lt open type fuse unit arrangement single, erection lt open type fuse unit arrangement double, painting of stru. complete excluding dt [two coat of red oxide] all metal parts(excluding cost of paint)., painting of stru. complete excluding dt [one coat alu paint, excluding cost of paint), colour washing of 2 numbers structure pole [excluding c