Tender For tender for work of providing, laying and linking 250mm dia dwc sanitary pipeline along haraluru main road from dsr ultima apartment to birla circle junction at haraluru village and near sarjapur rob from service road to carmelaram trenchless point coming under haraluru service station of aee se-3 sub division.
Tender For corrigendum : supply of design supply installation testing and commissioning of chemical enginnering dcif lab furniture c c - u shaped wall table with under bench base cabinets , island table with under bench base cabinet and sink unit , wall cupboard , lab stool , bio safety cabinet , fume hood , ducting and blower , eyewash unit , sink unit with eyewasher , slotted angle rack with adjustable shelves , online ups 20 kw , gas pipeline , aluminium partition
Tender For providing of custom bid for services - rpnc253047 annual rate contract for carrying out replacement of oval header plates and tle tubes of srt vi heaters of ncu at panipat naphtha cracker panipat
Tender For corrigendum : providing of custom bid for services - carrying out depth of cover survey, population density survey and soil resistivity survey of jetty pipelines under paradip and vizag marketing terminals
Tender For corrigendum : supply of c73340415174 supply of high static pressure ductable ac unit capacity 8point5 tr having one indoor and one out door unit refer annexure-iii , 100000000000 supply of suitable size refrigerant grade copper piping between indoor and outdoor units of ductable split ac units 8point5 tr refer annexure-iii , 100000000001 providing cpvc sdr11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain from the ac indoor refer annexure-iii , 100000000002 providing of cpvc sdr11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain refer annexure-iii , 100000000003 supplying of xlpe insulated, pvc sheathed, armoured, copper conductor, 1point1 kv grade lt cable of size 4 core - 6 sqmm refer annexure-iii , 100000000004 supply of xlpe insulated, pvc sheathe, copper conductor, 1point1 kv grade lt cable of size 4 core - 2point5 sqmm refer annexure-iii , 100000000005 supply of 150 mm width x 50 mm depth x 1point6 mm thickness of perforated hot dipped galvanised iron cable tray refer annexure-iii , 100000000006 installation testing and commissioning of high static pressure ductable ac unit capacity 8point5 tr refer annexure-iv , 100000000007 erection testing and commissioning of suitable size refrigerant grade copper piping between indoor and outdoor units refer annexure-iv , 100000000008 laying of cpvc sdr11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain refer annexure-iv , 100000000009 laying of cpvc sdr11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation refer annexure-iv , 100000000010 laying of xlpe insulated, pvc sheathed, armoured, copper conductor 1point1 kv grade lt cable of size 4 core - 6 sq mm refer annexure-iv , 100000000011 laying of xlpe insulated, pvc sheathe, copper conductor 1point1 kv grade lt cable of size 4 core - 2point5 sqmm refer annexure-iv , 100000000012 installation of 150 mm width x 50 mm depth x 1point6 mm thickness of perforated hot dipped galvanised iron cable tray refer annexure-iv , 100000000013 dismantling and shifting of existing ductable indoor and outdoor 2 x8point5 tr refer annexure-iv
Tender For corrigendum : supply of c73340100470 supply of cassette ac four way capacity 2 tr minimum 5 star rating refer annexure ii-a , 100000000000 supply of suitable size refrigerant grade copper piping between indoor and outdoor units for 2tr cassette acorsplit ac unit refer annexure ii-a , 100000000001 providing flexible pvc duct hose covering pipe gray colour of size 60 mm refer annexure ii-a , 100000000002 providingcpvc sdr11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation refer annexure ii-a , 100000000003 providing cpvc sdr11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation refer annexure ii-a , 100000000004 supply of following size lt power cable with copper conductor xlpeorpvc insulation refer annexure ii-a , 100000000005 supply of copper cable of size 4 core - 2point5 sq mmfor communication refer annexure ii-a , 100000000006 supply of perforated hot dipped galvanised iron cable tray of size150 mm width x 50 mm depth x 1point6 mm thickness refer annexure ii-a , 100000000007 installation testing and commissioning of cassette ac four way capacity 2 tr minimum 5 star rating refer annexure ii-b , 100000000008 erection testing and commissioning of suitable size refrigerant grade copper piping between indoor and outdoor units for 2 cassette ac unit refer annexure ii-b , 100000000009 laying of flexible pvc duct hose covering pipe gray colour of size 60 mm refer annexure ii-b , 100000000010 laying of cpvc sdr11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation refer annexure ii-b , 100000000011 laying of cpvc sdr11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation refer annexure ii-b , 100000000012 laying of following size lt power cable with copper conductor refer annexure ii-b , 100000000013 laying of copper cable of size 4 core - 2point5 sq mm for communication refer annexure ii-b , 100000000014 installing of perforated hot dipped galvanised iron cable tray of size150 mm width x 50 mm depth x 1point6 mm thickness refer annexure ii-b , 100000000015 dismantling and shifting of existing cassette ac 4 nos including associated supprots cu piping etc refer annexure ii-b