Tender For corrigendum : purchase of equipments - purchase of equipment, 1. configuration design an 8-channel battery analyzer and its accessories 2. power 425 w3. voltage measuring range: 25 mv to 5 v, discharge minimum voltage: 0v or better, accuracy: 0.05% of fs4. current range: 0.5 ma to 6 a, accuracy: 0.05% of fs or better 5. power per channel output power: 30w, stability; +/- 0.1% of fs or better6. time rise time: 1ms (0~full range)7. frequency 10hz8. charge mode of operation: cc, cv, cccv, cp end conditions: voltage, current, relative time, capacity.9. discharge mode of operation: cc, cv, cp, cr, end conditions: voltage, current, test time, capacity, energy.10. pulse mode charge: cp mode, cc mode, discharge: cc mode, cp mode, min pulse width: 500ms, automated switch: automated switch from charge to discharge for each pulse end condition: voltage, relative time11. dcir support for the calculation of the point of the dcir12. cycle cycles: 1 65500 or better, steps: 250 or better, nested function: max three levels of loops13. protective function software, power-down data protection, user-defined safety (upper and lower) tolerance of current, voltage, and delay time14. channel features independent pairs of closed loops for the constant current source and constant-voltage source15. test reports and curves for analysis different types of curves created by software based on user definition. (voltage-time curve, current-time curve, capacity-voltage curve, loops times charge/discharge capacity curve, loops times charge/ discharge efficiency curve, etc.), data reports created by the software. comparison of the performance of the batteries tested in channels, both visually and statistically16. channels independent control17. ac input ac 220v 10% / 50hz 18. voltage and current testing sample 4 wire connecting 19. noise 85db20. data management mysql database21. communication means tcp/ip protocol22. data output excel, txt23. communication interface ethernet port24. number of channels per cabinet 825. accessories: 1. bi-potentiostat: electrochemical workstation or moduletechniques the system should be capable of running the rde / rrde technique simultaneously cyclic voltammetry (cv) with simulation/fitting programs linear sweep voltammetry (lsv) with stripping bulk electrolysis with coulometry (be) differential pulse voltammetry (dpv) with stripping normal pulse voltammetry (npv) with stripping tafel plot (tafel), potentiodynamic deactivation, pitting corrosion, corrosion rate, linear polarization, corrosion current, etc. multi-current steps (istep) amperometric i-t curve (i-t) lifetime testing open circuit potential time (ocpt) chrono amperometry (ca) chrono coulometry (cc) chronopotentiometry with current ramp (cpcr) potentiometric stripping analysis (psa) auxiliary signal measurement channel ir compensation external potential input galvanostatic charge discharge single/multiple cycle -chrono potentiometry (cp) with potential limits, polarity by potential or time, no. of cycles etc. voltage vs current density curves single or multiple potential steps with charge limits, single or multiple current steps, mixed voltage/current control using macro. i-v measurements, i max, pmax, fill factor, etc.impedance ac impedance (imp) 10 hz to 3mhz impedance time (impt) (mott-schottky) impedance potential (impe) impedance simulator with fitting open circuit potential time (ocpt)hardware specification of bi-potentiostat workstation/ module: potentiostat / galvanostat module, 2- or 3- or 4-electrode configuration maximum potential: 10v, maximum current: 250 ma peak or better and 2 amps with +/-25 volts for higher current measurement. compliance voltage: > 13v or better, potentiostat rise time: 300 ns or better galvanostat applied current range: 3na to +/- 100ma or better and upto 2 amps applied current accuracy: 20 pa or better input bias current: 1 pa or better cv and lsv scan rate: 0.000001 to 10,000 v/s. ca and cc pulse width: 0.0001 to 1000 sec imp freque
Tender For providing of hiring of boats - tugboat; less than 20; without air-conditioning; 4-6 persons; 100; sterndrive; steel; as mandatory, rescue life jackets, lifebuoys, fire extinguisher, first aid box, safety hand lamp, fire blanket, foot pump; service provider
Tender For corrigendum : repair replacement ofcertain repair to fire pump motors fire hydrants defected rusted water pipe lines along with connected works at various locations recently received from cce rnd and etc under ge i rci rnd rci hyderabad
Tender For supply of cssd and general surgical disposable items- cal 3 - double pressure transducer kit with cable(edward compitable), close section neonatal colour coded for control depth sectioning(1x1), bp bulb rubber with control valve(1x1), close section neonatal no & color coded graduation for controlled depth suctioning 7fr (1x1)---, close section neonatal no & color coded graduation for controlled depth suctioning 6fr (1x1)---, cannulaid no. 1,2,3,4 (1x1)---, water bed ( pead ) (1x1)---, water bed ( adult ) (1x1)---, povidone iodine tulle 10x10 cm (1x1)---, b.p cuff with rubber bag (1x1)---, close section neonatal no & color coded graduation for controlled depth suctioning 8fr (1x1)---, pencil point spinal needle 25x12cms---, pencil point spinal needle 29x9cms---, nerve block needles ultrasound guided with removable polyurythene extension line 3.5 cms---, maccoy blades set no 2,3,4---, magill forceps small, medium, large---, fmt profile soft seal cuff straight /magill curve (5 to 8.5)---, endotracheal tube siliconized without cuff pvc no- 2 (1x1)---, scented large adult anaesthetic face masks with hook ring size (0 to 6)---, tube support malleable neonatal---, tube support malleable adult---, gel closed head ring paed---, gel closed head ring adult---, breathing bag 2.0 litre---, breathing bag 1.0 litre---, resuscitator.autoclavable with reservoir 500ml (ped) silicon 1x1---, resuscitator.autoclavable with reservoir 250ml (neonatal) silicon 1x1---, resuscitator.autoclavable with reservoir 1000ml /1600ml(adult) silicon 1x1---, anatomical face mask 06 reprocesable autoclavable upto maximum temp 137 degree c (1x1)---, open ligaclip applicator---, venturi face mask kit with set of venturi valves (1x1)---, usg machine probe steriled disposable bag (1x1)---, t piece for weaning (1x1)---, ryles tube with leadline no-5 (1x1)---, paediatric iv support (1x1)---, neonatal iv support (1x1)---, collagen dressing 10x10cm (1x1)---, course diamond burr compatible to medtronic system (1x1)---, codon filter (1x1)---, aurolac silicone tube for dcr (1x1)---, asepto syringe (1x1)---, adhesive incise drape 40x42 (1x1)---, abdominal drain kit sterile eo size f26 (1x1)---, abdominal drain kit sterile eo size f22 (1x1)---, barbed suture no. 0 round body---, barbed sutures 3-0 adustable fixed loop 3-0 24mm 3/8 circle reverse cutting (1x12 foils)---, barbed sutures 2-0 adustable fixed loop 2-0 24mm 3/8 circle reverse cutting (1x12 foils)---, synthetic absorbable antibacterial triclosan coated polyglactin 6-0 circle spatulated micro-point double needle 8mm violet braided 45cm (1x12 foils)---, monofilament polypropylene 8-0 1/2 circle round body 60cm (1x12 foils)---, suture polypropylene 7-0 0.5 metric 60cm, 9.3mm 3/8 circle tapercut (1x12 foils)---, polydioxanone (pds) 6 pack size (1x12 foils)---, polydioxanone (pds) 5 pack size (1x12 foils---, polydioxanone (pds) 4 pack size (1x12 foils---, polydioxanone (pds) 3 pack size (1x12 foils)---, polydioxanone (pds) 2 pack size (1x12 foils)---, polydioxanone (pds) 1 pack size (1x12 foils)---, monofilament black polyamide 9-0 6mm 3/8 circle spatulated needle 38cm (1x12 foils)---, monofilament polypropylene 8-0, 1/2 circle round body 60cm---, vaccum assisted closure set (1x1)---, monofilament poly propylene mesh size 15cmx15 cm (1x1)---, pencil point spinal needle paediatric 25x3.8cms---, tracheostomy tube blue line ultra with cuff two linner cannula size -7.0 (1x1)---, tracheostomy tube blue line siliconized p v c without cuff size -4.5 (1x1)---, tracheostomy tube blue line siliconized p v c without cuff size -4.0 (1x1)---, tracheostomy tube blue line siliconized p v c without cuff size -3.5 (1x1)---, tracheostomy tube blue line siliconized p v c without cuff size -3.0 (1x1)---, tracheal balloon dilator no.12 (1x1)---, terumo guidewire 0.0325 straight tip 150 cm(1x1)---, single limb circuit (1x1)---, silicon suction tube (transparent ) 1x30 mtr (1x1)---, shepherds grommet paediatric (1x1)---, shah gromme
Tender For repair/maint of pump/ motor set and allied services and repair/maint of fire hydrant system and other connected work at air force station jaisalmer
Tender For providing consultancy services for obtaining initial fire noc from kerala fire and rescue department including all statutory payments for main academic building, simulator building and hostel building at imu, kochi campus, kochi