Get complete information related to latest Ac Controller Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ac Controller Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ac Controller Tenders.
Tender For restoration of 500 lpm ogp at sub district hospital sunderbani - servicing of air compressor of 500 lpm ogp by way of removing old air oil separator-02 nos, air filter -02 nos, oil filter- 02 nos, and draining compressor oil 40 litres and providing and fitting of new air oil separator 02 nos, air filter 02 nos, oil filter -02 nos, and compressor oil 40 litre. the job includes cost of material and labour charges for repair at site and all taxes as applicable.(compressor make fscurtis model: sem-60-a115electrical motor: 45kw, 60hp, 400v, 50hz), repair to gas pipe line system by way of checking out of leakages of 15mm, 28mm and 42mm copper pipe by way of gas welding/brazing ,replacement of damaged valves of 28mm & 42mm. the job includes cost of material and labour charges for repair at site and all taxes as applicable., repair to electrical main panel of the plant by replacing the damaged 160 amp and 125 amps 3 pole mccb . the job includes cost of material and labour charges for repair at site and all taxes as applicable
Tender For supply of filter feed pump , activated carbon filter media , supplying installation testing and commissioning of mbbr fab media , supplying testing and commissioning of main mcc panel mccb , repairing testing and commissioning of vertical garden supply pump , supply installation testing and commissioning of nonsubmersible sewage pumps , supply installation testing and commissioning of drainage submersible pumps , sludge pump and accessories
Tender For corrigendum : tender for supply of equipment design erection tetsing and commissioning for sop to 4g bsnl tower authority by providing single phase lt line at lagga chalga along with augmentation of existing dtr under esd chamba no ii - supply of lt line with acsr 6/1/2.59 mm sq. on steel poles (0.060 km)vill. lagga and aug. of 11/.4 kv 25 kva to 63 kvs s/stn. lagga section sahoo esd chamba-ii t.s.no. 97/24-25), acsr 6/1/2.59 (30mm ) {includes 2 conductor lengths for 1 and additional 1% (sag, jumpering and wastage}, prov. steel tubular poles.8mtrs, muff for steel tubular pole (1800mm long) with concrete filling, shackle insulator with d-iron, stay set complete in all respect, stay wire (7/3.15 mm) (8.0 kg per stay set), prov. g.i. wire 8swg, prov. egg insulator, prov. eye hook, nut & bolts off size, aluminium paint, erection of lt line with acsr 6/1/2.59 mm sq. on steel poles (0.060 km)vill. lagga and aug. of 11/.4 kv 25 kva to 63 kvs s/stn. lagga section sahoo esd chamba-ii t.s.no. 97/24-25), acsr 6/1/2.59 (30mm ) {includes 2 conductor lengths for 1 and additional 1% (sag, jumpering and wastage}, prov. steel tubular poles.8mtrs, muff for steel tubular pole (1800mm long) with concrete filling, shackle insulator with d-iron, stay set complete in all respect, stay wire (7/3.15 mm) (8.0 kg per stay set), prov. g.i. wire 8swg, prov. egg insulator, prov. eye hook, nut & bolts off size, aluminium paint, supply of aug. of 11/.4 kv 25 kva to 63 kvs s/stn. lagga, prov. 11/.4 kv, 63 kva s/stn., pipe earthing with gi,charcoal & salt, prov. lt distribution panel with mccb (160 a, 10 ka, 4p,1 no.) & sfu (32 a 5 no. rewireble) for 63kva trf. as per specification, lt cable 3-1/2 core-70mm sq., surge arrester, 9 kv station class, aluminium thimbles, copper thimble, energy meter (3-phase, 4-wire) dlms compliant 1000/5 a ct type for 63 kva transformer, erection of aug. of 11/.4 kv 25 kva to 63 kvs s/stn. lagga, prov. 11/.4 kv, 63 kva s/stn., pipe earthing with gi,charcoal & salt, prov. lt distribution panel with mccb (160 a, 10 ka, 4p,1 no.) & sfu (32 a 5 no. rewireble) for 63kva trf. as per specification, lt cable 3-1/2 core-70mm sq., surge arrester, 9 kv station class, aluminium thimbles, copper thimble, energy meter (3-phase, 4-wire) dlms compliant 1000/5 a ct type for 63 kva transformer, mannual carriage of existing & new transf.(25 & 63 kva) 2.00 km back to store, supply of lt line with acsr 6/1/2.59 mm sq. on steel poles (0.650km) vill. chalga section chaned esd chamba-ii t.s.no.96 /24-25), acsr 6/1/2.59 (30mm ) {includes 2 conductor lengths for 1 and additional 1% (sag, jumpering and wastage}, prov. steel tubular poles. 8mtrs, prov. steel tubular poles. 9mtrs, muff for steel tubular pole (2000mm long) with concrete filling, shackle insulator with d-iron, stay set complete in all respect, stay wire (7/3.15 mm) (8.0 kg per stay set), prov. g.i. wire 8swg, prov. egg insulator, prov. eye hook, nut & bolts off size, coil earthing, aluminium paint, erection of lt line with acsr 6/1/2.59 mm sq. on steel poles (0.650km) vill. chalga section chaned esd chamba-ii t.s.no.96/24-25), acsr 6/1/2.59 (30mm ) {includes 2 conductor lengths for 1 and additional 1% (sag, jumpering and wastage}, prov. steel tubular poles. 8mtrs, prov. steel tubular poles. 9mtrs, muff for steel tubular pole (2000mm long) with concrete filling, shackle insulator with d-iron, stay set complete in all respect, stay wire (7/3.15 mm) (8.0 kg per stay set), prov. g.i. wire 8swg, prov. egg insulator, prov. eye hook, nut & bolts off size, coil earthing, aluminium paint
Tender For corrigendum : supply of mccb 100a 4 pole for 40 kva genr set , avr for 40 kva genr set , panel display unit kg 934 for 40 kva genr set , control switch for 40 kva genr set , door catch assy for 40 kva genr set , door hinges for 40 kva genr set , fuel filter for 40 kva genr set , air filter for 40 kva genr set , oil filter for 40 kva genr set , fuel pipe 19x19x2 mtr for 40 kva genr set , fuel pipe 19x19x1.5 mtr for 40 kva genr set , fuel pipe 19x19x1 mtr for 40 kva genr set , fuel feed pump for 40 kva genr set , fan belt for 40 kva genr set , fuel tank cap for 40 kva genr set , bolt 19mm for 40 kva genr set , tappet cover gasket for 40 kva genr set
Tender For procurement of electrical components and minor equipment for lab - single-phase auto transformer (0-270v, 35a), three-phase voltage sensors (used for both ac and dc sensing capability) with high accuracy along with dso probes, three-phase current sensors (used for both ac and dc sensing capability) with high accuracy along with dso probes, three-phase autotransformer (440v, 40a), powering boards for sensors and gate driver circuits (15v, 12v, 5v), soldering iron with controllable temperature - medium (weller), gsr 120-li small rechargeable driller (bosch), lrs-600-12 dc power supply/smps mean well 12v, 50a, 600w, lrs-600-15 dc power supply/smps mean well 15v, 40a, 600w, lrs-600-24 dc power supply/smps mean well 24v, 25a, 600w, lrs-600-36 dc power supply/smps mean well 36v, 16.6a, 597.6w, lrs-600-48 dc power supply/smps mean well 48v, 12.5a, 600w, fluke multimeter 0-600v, 0-10a, rheostat 200 ohm, 20a, tektronix a622 ac/dc current probe, skkt 107/16 e- thyristor modules (1.6kv, 119a), scr module heat-sink, scr firing module, inductor filter (50a), mccb (60a), ganged potentiometer (5 ??, 3watt), digital panel mount ammeter (75a), digital panel mount ammeter (1000v), 10sq mm wire, dc shunt (75mv, 75a), lugs, hardware (base plate for scr module), single sw sic-mosfet module, sic-mosfet switches (silicon carbide mosfet, single, n, channel, 55 a, 1.2, kv, 0.075 ohm, to-247), single sw sic-mosfet gate driver, 10a igbt and sic mosfet gate drive with integrated overcurrent sensing, fault, and uvlo status feedback features acpl-, 355jc based design