Tender For providing of repair, maintenance and installation of plant/ systems/equipments - manufacturing unit; complete overhauling of ksb make boiler feed water pump of hp nitric acid plant on proprietary basis as per sow and quantum of job; service provider
Tender For corrigendum : supply of boiler feed water pump(without motor) model no: cr 32-11- 2-a-f-a-ehqqe as per technical specificatio (q3) , shaft seal for above model no: cr 32-11-2-a-f-a-ehqqe (q3) , bottom bearing for above model no: cr 32-11-2-a-f-a-ehqqe (q3)
Tender For corrigendum : supply of spares for overhauling of boiler feed water pumppump centrifugal, bearing oil cooler coil, bearing cover, allen grub screw, hexagon head screw
Tender For providing of repair, maintenance and installation of plant/ systems/equipments - rr site 5 and 6; preventive maintenance checks of auxiliary boiler feed pump abfp for details refer boq item no 1 in scope of work and 01 quantity is equal to 2 nos; service provider , repair, maintenance and installation of plant/ systems/equipments - rr site 5 and 6; preventive maintenance checks of rdp and sdp for details refer boq item no 2 in scope of work and 01 quantity is equal to 8 nos; service provider , repair, maintenance and installation of plant/ systems/equipments - rr site 5 and 6; overhauling of pump horizontally installed having motor rating above 100 kw and up to 600 kw for details refer boq item no 3 in scope of work and 01 quantity is equa.. , repair, maintenance and installation of plant/ systems/equipments - rr site 5 and 6; overhauling of pump vertically installed having motor rating above 100 kw and up to 600 kw for details refer boq item no 4 in scope of work and 01 quantity is equal .. , repair, maintenance and installation of plant/ systems/equipments - rr site 5 and 6; replacement of rotating assembly of cep for details refer boq item no 5 in scope of work and 01 quantity is equal to 1 nos; service provider , repair, maintenance and installation of plant/ systems/equipments - rr site 5 and 6; overhauling of ccw plant water pump vertically installed having motor rating above 900 kw and up to 1200 kw for details refer boq item no 6 in scope of work and 01 q.. , repair, maintenance and installation of plant/ systems/equipments - rr site 5 and 6; preventive maintenance checks of pumps horizontal vertical having motor rating upto 50 kw for details refer boq item no 7 in scope of work and 01 quantity is equal .. , repair, maintenance and installation of plant/ systems/equipments - rr site 5 and 6; preventive maintenance checks of pumps horizontal vertical having motor rating more than 100 kw to 400 kw except apwc pump for details refer boq item no 8 in scope o.. , repair, maintenance and installation of plant/ systems/equipments - rr site 5 and 6; preventive maintenance two yearly checks of apwc pump vertically installed double suction single stage having motor rating 200 kw for details refer boq item no 9 in.. , repair, maintenance and installation of plant/ systems/equipments - rr site 5 and 6; preventive maintenance checks of cep ccw plant water pumps having motor rating 900 kw to 1200 kw for details refer boq item no 10 in scope of work and 01 quantity is.. , repair, maintenance and installation of plant/ systems/equipments - rr site 5 and 6; overhauling of electrical motor rating more than 30 kw and up to 100 kw for details refer boq item no 11 in scope of work and 01 quantity is equal to 3 nos; service .. , repair, maintenance and installation of plant/ systems/equipments - rr site 5 and 6; overhauling of electrical motor rating more than 100 kw and up to 600 kw for details refer boq item no 12 in scope of work and 01 quantity is equal to 5 nos; service.. , repair, maintenance and installation of plant/ systems/equipments - rr site 5 and 6; overhauling of electrical motor rating from 850 kw and up to 1200 kw cepccw plant water pump motor for details refer boq item no 13 in scope of work and 01 quantity .. , repair, maintenance and installation of plant/ systems/equipments - rr site 5 and 6; overhauling of rotating assembly of condensate extraction pump cep for details refer boq item no 14 in scope of work and 01 quantity is equal to 1 nos; service provi.. , repair, maintenance and installation of plant/ systems/equipments - rr site 5 and 6; overhauling of actuator operated electrical pneumatic valves except asdv csdv and msiv for details refer boq item no 15 in scope of work and 01 quantity is equal to .. , repair, maintenance and installation of plant/ systems/equipments - rr site 5 and 6; overhauling of actuator control valve isolating valve of air operated valves for details refer boq item no 16 in scope of work and
Tender For corrigendum : procurement of spares of boiler feed pump model fk6d30 and booster pump model fa1b56 installed at unit no. 3 and 4, sgtps, mppgcl, birsinghpur - oil guard inboard & outboard (de & nde)oil throwersplit floating oil seal(bronze)water jacket 'o' ring 8" od & 7.734" id x 0.139"water jacket 'o' ring 7.750" od x 7.484" id x 0.139"water jacket dewater jacket ndesuction cover o' ring 16" od x 15.475" id x 0.275"discharge cover o' ring 19.5" od x 18.975" id x 0.275"thrust collorthrust collor key 8.7 x 24thrust collor lock washerthrust collor lock nutend cover o' ring 7.500" od x 7.234" id x 0.139"coupling key 22x14x92coupling retaining nut m 75 rhjournal bearingthrust bearingspares for booster pump, model:-fa1b56coupling keyoil retaining ring de & ndebearing (journal) de & ndethrust bearingcasing ringbushing ringimpeller wear ringthrust collorthrust collor (lock washer)thrust collor keythrust collor lock nutsplit floating oil sealseal sleeve keycoupling nutwater jacket de & ndeimpeller lock nut (de & nde)impeller lock washer"o" ring end cover"o" ring (0.21" x 11.475 id)stud & nut m-30stud & nut m-24hex screw m-12socket head cap screw m-16