Get complete information related to latest Ac Motor Slip Ring Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ac Motor Slip Ring Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ac Motor Slip Ring Tenders.
Tender For supply of pump assy part no 15100m-830a0 alt no 15100m830a1 , fuel filter part no 15410m-830a0 alt no 15410m830a1 , filter assy oil part no 16510m 73080 alt no 16510m73070 , spark plug part no 0948200429 alt no 09482m00551 , body assy throttle part no 13400m-830a0 alt no 13401m830a1 , engine mounting pad front part no 11610m80020 , injector assy fuel part no 15710m-83f00 alt no 15710m83f00 , sensor oxygen part no 18213-61a10 alt no 18213m80c11 , disc clutch part no 22400m-83060 alt no 22400m83060 , clutch pressure plate part no 22100m83060 alt no 22100m83060 , shaft assy propeller no 01 part no 27101-83101 alt no 27101m83110 , shaft assy propeller part no 2710283101 alt no 27102m83110 , shaft assy propeller part no 2710383301 alt no 27103m83311 , cord set higtention part no 33705m-80c10 alt no 33705m80c10 , shock absorber assy front part no 41600m80030 , front oil seal small part no 0928350002 alt no 09283-50002 , spring assy part no 41310m80350 alt no 41310m75m00 , spring assy rear lh part no 41310m-80360 alt no 41311m75m00 , shock absorber assy rear part no 41700m80031 , oil seal rear axle part no 09283-48007 , protector oil seal part no 4358873000 alt no 43588-73000 , caliper assy disc brake part no 55100m70430 alt no 55100m70a40 , disc front break part no 55211m-80010 alt no 55211m75m00 , end tie rod part no 48810m-60a00 alt no 48810m75m00 , coilignition part no 33400-65g00 alt no 33400m78l00 , joint assy universal part no 27200m-83810 alt no 27200-83813 , element air cleaner part no 13780-83000 , horn assy high part no 38500m 78122 alt no 38500m78122 , spring assy front part no 41110m 80031 alt no 41110m75m00 , brake pad part no 55810m70a00 , shoe set rear brake part no 53200m83050 , motor assy starting part no 31100m80c00 , axle shaft rh part no 44211m70a00 alt no 44211m75m00 , cam shaft part no 12710m830a0 , seal oil part no 09283m32042 alt no 12739m78l00 , axle shaft rh part no 44221m70a00 , bushing set part no 42412m75m00 , bushing spring set part no 99000m24120
Tender For tender for supply of spring assy rear lh , king pin , cushion assy rh front soft top , end steering tie rod , link assy wiper , cable parking brake no 2 , lamp assy combination rh , tie rod steering , yoke joint flange , bush stabliser mount , cord set high tension , cord set high tension , lever gear shifting control , lamp assy side turn signal lh , cable starting motor , bar comp fr bumper , hose outlet
Tender For corrigendum : rc for call basis repairs and misc works of split ac in various bas of ec mumbai - attending complaint and wet servicing of ac unit upto 50 kms , attending complaint and wet servicing of ac unit upto 51 to 100 kms , attending complaint and wet servicing of ac unit above 101 kms , replacement of starting capacitor 80 to 100 mfd of ac unit , replacement of running capacitor 36 to 50 mfd of ac unit , replacement of capacitor for condenser fan 4 to 6 mfd of ac unit , replacement of sensor for split ac unit , replacement of contactor relay for split ac outdoor unit , replacement of starting relay of ac unit , replacement of thermostat of ac unit , replacement of selector switch of ac unit , replacement of blade for condensor of window or split ac unit , replacement of blower assembly for split ac unit without motor , replacement of pcb for conventional split ac indoor unit of 1.5 tr , replacement of pcb for outdoor unit of invertor type split ac , replacement of pcb for indoor unit of invertor type split ac , replacement of 1.5tr or 2tr split ac remote , replacement of fan motor for condenser unit of conventional 1.5 or 2 tr of ac , replacement of blower motor for indoor unit of 1.5tr or 2 tr of split ac , replacement of 20mm dia flexible pvc pipe for drain water connection of ac , charging of r22 or r32 or r134 or r410 refrigerant gas upto the optimum working pressure suitable for 1.5 or 2tr ac alongwith attending leakage , replacement of cond coil manufactured with cu tube and al fins with antirust coating and blue fin hydrophilic coating for sac incl. credit of old coil , dismantling of window ac unit alongwith casing ms supporting frame , dismantling of split or high sensible ac incl. id and od unit aw all acc. pump down of gas and keeping all dismantled material at safe location , transportation of dismantled 2 no. ac units upto 20 km with all accessories incl. hiring of vehicle, manpower etc , transportation of dismantled 3no. to 5 no. ac units upto 20 km with all accessories incl. hiring of vehicle, manpower etc , transportation of dismantled 2 no. ac units from 21 km to 50 km with all accessories incl. hiring of vehicle, manpower etc , transportation of dismantled 3no. to 5 no. ac units from 21 km to 50 km with all accessories incl. hiring of vehicle, manpower etc , transportation of dismantled 2 no. ac units from 51 km to 100 km with all accessories incl. hiring of vehicle, manpower etc , transportation of dismantled 3no. to 5 no. ac units from 51 km to 100 km with all accessories incl. hiring of vehicle, manpower etc , transportation of dismantled 3no. to 5 no. ac units from 100 km upto 200 km with all accessories incl. hiring of vehicle, manpower etc , itc of 1.5 or 2tr window ac unit with properly finshing and minor civil work , itc of wall mounting type 1.5 or 2tr split ac unit with properly finishing and minor civil work , itc of 2x1.5 tr high sensible ac unit with properly finishing and minor civil work , s and f of 1 by 4 inch copper refrigeration pipe , s and f of 3 by 8 inch copper refrigeration pipe , s and f of 1 by 2 inch copper refrigeration pipe , s and f of 5 by 8 inch copper refrigeration pipe , p and w of expanded polyethylene foam tube insulation for 1 by 4 inch copper refrigeration pipe , p and w of expanded polyethylene foam tube insulation for 3 by 8 inch copper refrigeration pipe , p and w of expanded polyethylene foam tube insulation for 1 by 2 inch copper refrigeration pipe , p and w of expanded polyethylene foam tube insulation for 5 by 8 inch copper refrigeration pipe , s and f of prefabricated powder coated heavy duty iron stand having projection arm minimum 600 mm , s and fabrication of m.s. frame made out of various m.s. sections incl. hardwares finishing, painting, minor civil work etc , p and f of 12mm thick prelaminated particle board with decorative lamination on both side flat pressed 3 layer or graded wood particle board , s and l of 4 x 1.5 sq mm copper conductor unarmoured
Tender For corrigendum : rc for call basis repairs and misc works of split ac in various bas of ec nagpur - attending complaint and wet servicing of ac unit upto 50 kms , attending complaint and wet servicing of ac unit upto 51 to 100 kms , attending complaint and wet servicing of ac unit above 101 kms , replacement of starting capacitor 80 to 100 mfd of ac unit , replacement of running capacitor 36 to 50 mfd of ac unit , replacement of capacitor for condenser fan 4 to 6 mfd of ac unit , replacement of sensor for split ac unit , replacement of contactor relay for split ac outdoor unit , replacement of starting relay of ac unit , replacement of thermostat of ac unit , replacement of selector switch of ac unit , replacement of blade for condensor of window or split ac unit , replacement of blower assembly for split ac unit without motor , replacement of pcb for conventional split ac indoor unit of 1.5 tr , replacement of pcb for outdoor unit of invertor type split ac , replacement of pcb for indoor unit of invertor type split ac , replacement of 1.5tr or 2tr split ac remote , replacement of fan motor for condenser unit of conventional 1.5 or 2 tr of ac , replacement of blower motor for indoor unit of 1.5tr or 2 tr of split ac , replacement of 20mm dia flexible pvc pipe for drain water connection of ac , charging of r22 or r32 or r134 or r410 refrigerant gas upto the optimum working pressure suitable for 1.5 or 2tr ac alongwith attending leakage , replacement of cond coil manufactured with cu tube and al fins with antirust coating and blue fin hydrophilic coating for sac incl. credit of old coil , dismantling of window ac unit alongwith casing ms supporting frame , dismantling of split or high sensible ac incl. id and od unit aw all acc. pump down of gas and keeping all dismantled material at safe location , transportation of dismantled 2 no. ac units upto 20 km with all accessories incl. hiring of vehicle, manpower etc , transportation of dismantled 3no. to 5 no. ac units upto 20 km with all accessories incl. hiring of vehicle, manpower etc , transportation of dismantled 2 no. ac units from 21 km to 50 km with all accessories incl. hiring of vehicle, manpower etc , transportation of dismantled 3no. to 5 no. ac units from 21 km to 50 km with all accessories incl. hiring of vehicle, manpower etc , transportation of dismantled 2 no. ac units from 51 km to 100 km with all accessories incl. hiring of vehicle, manpower etc , transportation of dismantled 3no. to 5 no. ac units from 51 km to 100 km with all accessories incl. hiring of vehicle, manpower etc , transportation of dismantled 3no. to 5 no. ac units from 100 km upto 200 km with all accessories incl. hiring of vehicle, manpower etc , itc of 1.5 or 2tr window ac unit with properly finshing and minor civil work , itc of wall mounting type 1.5 or 2tr split ac unit with properly finishing and minor civil work , itc of 2x1.5 tr high sensible ac unit with properly finishing and minor civil work , s and f of 1 by 4 inch copper refrigeration pipe , s and f of 3 by 8 inch copper refrigeration pipe , s and f of 1 by 2 inch copper refrigeration pipe , s and f of 5 by 8 inch copper refrigeration pipe , p and w of expanded polyethylene foam tube insulation for 1 by 4 inch copper refrigeration pipe , p and w of expanded polyethylene foam tube insulation for 3 by 8 inch copper refrigeration pipe , p and w of expanded polyethylene foam tube insulation for 1 by 2 inch copper refrigeration pipe , p and w of expanded polyethylene foam tube insulation for 5 by 8 inch copper refrigeration pipe , s and f of prefabricated powder coated heavy duty iron stand having projection arm minimum 600 mm , s and fabrication of m.s. frame made out of various m.s. sections incl. hardwares finishing, painting, minor civil work etc , p and f of 12mm thick prelaminated particle board with decorative lamination on both side flat pressed 3 layer or graded wood particle board , s and l of 4 x 1.5 sq mm copper conductor unarmoured
Tender For supply of transformer oil pump with motor and starting capacitor of 40 micro farad su itable for transformer of bg ac emu/memu conforming to icf specn. no. icf/elec/018 (re v.a) or latest amendment/alteration if any. model 1115t of m/s flow well engineering or equivalent. [ warranty period: 30 months after the date of delivery ]