Web Analytics Made Easy - StatCounter

Ac Sheet Roof Work Tenders

Get complete information related to latest Ac Sheet Roof Work Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ac Sheet Roof Work Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ac Sheet Roof Work Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :38553069 Due date: 02 Jan, 202502 Jan, 2025 28.92 Lacs
Tender For custom bid for services - upgardation of nom tensile structur-fabrication work- fabrication of vertical member galvanised iron 150*150*1.6 mm box section frames for, entrance canopy size 140feet (07 nos weighting 500 kgs, fabrication of harizontal 100*50 mm 16mm gi box, frame, (a) size-400 feet (20nos) section size-600 feet (30nos) weigning-1200 kgs for ceeling, fabrication of vertical section member of galvanised iron 60*40*1.6mm for blocking the view & beaufication of venue - weighing 1900kgs, fabrication of circular ribs cross section supporled on the glavanised pole size +8+200mm for beautification of bar counted- weighing-450 kgs, fabrication of raise wooden metal fabrication table, acp panneling for entrance canopy, sheet roofing with sunglansed polycarbonite sheet, setting up of bar counter, circular counter for serving with services providing of shelves for storage of bottle, providing of under counter refrigerator providing/fixing of customises basin sink, plumbing work, providing/fixing of under counter storage shelves size-10ft 2.5ft*2feet+10nos, providing/fixing of l shape counter with wooden laminate 19mm ply size-5ft *2.5*2ft application of alluminium composite panneling for back drop of bar counter, providing & fixing vertical racks for display beautification of counter size (10ft 6ft) fixing of inverted glass holder, high raised stool, surface preparation application of one coated oxide primer on the fabricalled structure, providing & application of powder coated antirustblack coat colour then on existings & jr new frames, painting work, +, providing & application of wave theme paint coat on the vertical ribs strcture, electrical work, providing & fixing of inverted hanging antique lights for beautification to light up the venue space, providing & fixing of spot light for the internal fabricated false ceeling & bar counter, providing/fixing of profile led lights for beautification, electricalpoints, switch/sockets/modular box, with, wiring2.5 sqmm 2 core (including laying) 1.5sqmm*2 core*150*95, cable concealed conduit pipes, main junction box, electrical labour charge, providing/fixing of projection screen 10+6, feet, led neon name board for venue 4ft*1.5ft, transportation as actual loading/unloading alabour charges, design consultant fee

CTN :38363368 Due date: 18 Dec, 202418 Dec, 2024 NA
Tender For sitc of various essential equipments for the use of various municipal maternity homes - 200/250 amp. 415v tpn switchfuse unit with crca sheet steel powder coated enclosure with hrc fuses & switch links and padlockable arrangement., cable end boxes 200/250 amp. tpn switch fuse, 200 amp. 415v fp on load changeover switch with crca sheet steel powder coated enclosure., supply, installation, testing and commissioning of 50kva dg set comprising of cpcb iv mech, built in amf panel, 1500 rpm, 4 stroke, 3 cylinder inline type, water cooled with radiator diesel, 1st category al armoured cables frls outer sheathed- 3.5c x 95 sq.mm, cable end termination for aluminium cables 3.5c x 95 sq.mm, 3 noss. single core cu pvc insulated flexible cable of 50 sq.mm. for phases & 1 single core cu pvc insulated flexible cable for neutral of 25 sq.mm for 100/125 amp. tpnss switch., cement concrete foundation using m-20 cement concrete mix with j shaped foundation bolts where required, supply & laying of double wall corrugated ( dwc) pipe 125 mm od / 109 mm i.d., concrate excavating the trenches and refilling the same after the cable is laid in approved manner (size of trench: 750 mm deep, 600 mm wide) in concrete/ masonary / asphalt. 1 cu. mtr. = 2.2 rmt., soil excavating the trenches and refilling,reinstatement of the same after the cable is laid in approved manner (750 mm deep, 600 mm wide),in all types of soils 1 cu. mtr. = 2.2 rmt., providing, detailing, composite fabricating members like trusses, ngirders,girders, bracings, supports, purlins, runners, and similar structural steel members fabricated using m.s. hollow tubular steel, bare galvalume/zincalume sheets for roofing, earthing station with 600 mm x 600 mm x 6 mm galvanised iron plate, 25 x 3mm gi, bare g. i. conductor size 10 swg., removal of switchgears/ dbs upto 200 amp., removal of switchgears/ dbs above 200 amp to 400 amp., removal of busbar chamber above 100 amp tpn to 800 amp tpn., removal of cable above 3-1/2 core x 35 sq. mm. to 3-1/2 core x 70 sq. mm, removal of cable from 1.5 sq.mm to 3-1/2 core x 35 sq.mm., refixing of 2 core/ 3 core/ 3-1/2 core / 4 core/ 6 core copper / aluminium conductor armoured / unarmoured cable 1.5 sq.mm. to 16 sq.mm. size on wall / ceiling etc., refixing of 2 core / 3 core / 3-1/2 core / 4 core/ 6 core copper / aluminium conductor armoured / unarmoured cable above 16 sq.mm. to 150 sq.mm. size on wall / ceiling etc., 415v main distribution panel 1 short circuit reating 50ka for 1 sec. 400a (thermal magnetic overload, short circuit release) mccb with rotary operating mechanism as incomer with digital ammeter,, 200a 4p mccb, 100a tpn mccb, 3 noss. single core cu pvc insulated flexible cable of 95 sq.mm. for phases & 1 single core cu pvc insulated flexible cable for neutral of 50 sq.mm for 200 amp tpnss switch., g.i. cable tray with all other accessories 150 x 25mm (w x h) - (16 swg - 1.6mm) without cover, cable end termination for aluminium cables 3.5c x 50 sq.mm, cable end termination for aluminium cables 3.5c x 120 sq.mm, cable end termination for aluminium cables 3.5c x 70 sq.mm, cable end termination for aluminium cables 3.5c x 50 sq.mm, 20w led flood light luminaire ip65, 1st category al armoured cables frls outer sheathed- 2c x 6.0 sq.mm, gun metal gate valves (screwed):-50 mm dia., gun metal non - return valve: (screwed):-50 mm dia., gun metal gate valves (screwed):-15 mm dia., gun metal foot valve 50 mm dia., automatic pump control panel, hose oil cooler to water pump, worm drive hose, fuel supply pipe, injector overflow pipe (return pipe), hose for oil cooler inlet, hose clip thermostat, vent hose (epdm) for gens, ax-45-cogged belt, hose water manifold to ther, dse 6120/ 4520 controller, battery exide 12v 110ah, oil filter 4 cyl -, fuel filter 4 cyl -, air filter element outer 4 cly m&m, centrifugal oil filter 4c, radiator aluminium, radiator exhaust fan, radiator core, charging alternator, alternator winding main, alternator ar

CTN :38388172 Due date: 18 Dec, 202418 Dec, 2024 NA
Tender For sitc of various essential equipments for the use of various municipal maternity homes - 200/250 amp. 415v tpn switchfuse unit with crca sheet steel powder coated enclosure with hrc fuses & switch links and padlockable arrangement., cable end boxes 200/250 amp. tpn switch fuse, 200 amp. 415v fp on load changeover switch with crca sheet steel powder coated enclosure., supply, installation, testing and commissioning of 50kva dg set comprising of cpcb iv mech, built in amf panel, 1500 rpm, 4 stroke, 3 cylinder inline type, water cooled with radiator diesel, 1st category al armoured cables frls outer sheathed- 3.5c x 95 sq.mm, cable end termination for aluminium cables 3.5c x 95 sq.mm, 3 noss. single core cu pvc insulated flexible cable of 50 sq.mm. for phases & 1 single core cu pvc insulated flexible cable for neutral of 25 sq.mm for 100/125 amp. tpnss switch., cement concrete foundation using m-20 cement concrete mix with j shaped foundation bolts where required, supply & laying of double wall corrugated ( dwc) pipe 125 mm od / 109 mm i.d., concrate excavating the trenches and refilling the same after the cable is laid in approved manner (size of trench: 750 mm deep, 600 mm wide) in concrete/ masonary / asphalt. 1 cu. mtr. = 2.2 rmt., soil excavating the trenches and refilling,reinstatement of the same after the cable is laid in approved manner (750 mm deep, 600 mm wide),in all types of soils 1 cu. mtr. = 2.2 rmt., providing, detailing, composite fabricating members like trusses, ngirders,girders, bracings, supports, purlins, runners, and similar structural steel members fabricated using m.s. hollow tubular steel, bare galvalume/zincalume sheets for roofing, earthing station with 600 mm x 600 mm x 6 mm galvanised iron plate, 25 x 3mm gi, bare g. i. conductor size 10 swg., removal of switchgears/ dbs upto 200 amp., removal of switchgears/ dbs above 200 amp to 400 amp., removal of busbar chamber above 100 amp tpn to 800 amp tpn., removal of cable above 3-1/2 core x 35 sq. mm. to 3-1/2 core x 70 sq. mm, removal of cable from 1.5 sq.mm to 3-1/2 core x 35 sq.mm., refixing of 2 core/ 3 core/ 3-1/2 core / 4 core/ 6 core copper / aluminium conductor armoured / unarmoured cable 1.5 sq.mm. to 16 sq.mm. size on wall / ceiling etc., refixing of 2 core / 3 core / 3-1/2 core / 4 core/ 6 core copper / aluminium conductor armoured / unarmoured cable above 16 sq.mm. to 150 sq.mm. size on wall / ceiling etc., 415v main distribution panel 1 short circuit reating 50ka for 1 sec. 400a (thermal magnetic overload, short circuit release) mccb with rotary operating mechanism as incomer with digital ammeter,, 200a 4p mccb, 100a tpn mccb, 3 noss. single core cu pvc insulated flexible cable of 95 sq.mm. for phases & 1 single core cu pvc insulated flexible cable for neutral of 50 sq.mm for 200 amp tpnss switch., g.i. cable tray with all other accessories 150 x 25mm (w x h) - (16 swg - 1.6mm) without cover, cable end termination for aluminium cables 3.5c x 50 sq.mm, cable end termination for aluminium cables 3.5c x 120 sq.mm, cable end termination for aluminium cables 3.5c x 70 sq.mm, cable end termination for aluminium cables 3.5c x 50 sq.mm, 20w led flood light luminaire ip65, 1st category al armoured cables frls outer sheathed- 2c x 6.0 sq.mm, gun metal gate valves (screwed):-50 mm dia., gun metal non - return valve: (screwed):-50 mm dia., gun metal gate valves (screwed):-15 mm dia., gun metal foot valve 50 mm dia., automatic pump control panel, hose oil cooler to water pump, worm drive hose, fuel supply pipe, injector overflow pipe (return pipe), hose for oil cooler inlet, hose clip thermostat, vent hose (epdm) for gens, ax-45-cogged belt, hose water manifold to ther, dse 6120/ 4520 controller, battery exide 12v 110ah, oil filter 4 cyl -, fuel filter 4 cyl -, air filter element outer 4 cly m&m, centrifugal oil filter 4c, radiator aluminium, radiator exhaust fan, radiator core, charging alternator, alternator winding main, alternator ar
 Loading, Please wait...

Connect us via What's Up