Web Analytics Made Easy - StatCounter

Adjuster Tube Tenders

Get complete information related to latest Adjuster Tube Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Adjuster Tube Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Adjuster Tube Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Corporations And Associations And Others

CTN :35500614 Due date: 24 Jun, 202424 Jun, 2024 NA
Tender For corrigendum : tender for the supplies of drugs and pharmaceuticals, labchemicals, x ray films and chemicals, surgicalsutures and dressings, vaccines, sera etc. and general items for the year 2023 25. - flexible soft mask for oxygen therapy: mask is to be designed for convenient oxygen therapy. manufactured from non-toxic medical grade pvc. to be provided with adjustable strap for proper positioning of mask on the nasal area. swivel connector for convenience of attachment to the oxygen tube. 200 to 210cm (app 7ft) multichannel tube is provided to ensure continuous flow of oxygen even if tube is accidentally kinked. proximal end of tube is fitted with soft funnel shape connector for easy connection to oxygen source.adult & child size individually packed in poly bag, solution: 0.55% orthophthaldehyde for rapid high level disinfection , entral feeding bag : 1.2 liter (approximate) capacity bag. ice pouch with bag for preserving food longer. feed transfer set directly connectd to the bag. hanger for the bag for suspending the bag from height (approxmiate 36 inch ). peel pack with fine regulation of flow device ,sterile ,single use, nasogastric tube--silicone: 100% base nasogastric tuble for entral feed - fg 12, 14, 16, infusion lipid : 20% lipid, breathing system--bipap /cpap: 22 f flixible fg port 1.6 meter smooth inner bore non collpasible wide bore tube with swivel 22m / 15f patient end , canula : 24 & 26 iv canula, adva needle technology, infusion: 3 in 1 combo parentral pack,10% amino acids with electrolytes & 50% dextrose with 20% fat emulsion, sodalime usp: 3 mm strands of sodalime as per usp, with pink to violet colour change with exhustion of co2 absorption power, the strands hsould co2 abosrpiton power of 19% and conforms to the moisture requirment of 12% to 19% range, it should comply with the hardness requirment of 75%, sodalime usp: 3 mm strands of sodalime as per usp, with pink to white colour change with exhustion of co2 absorption power, the strands hsould co2 abosrpiton power of 19% and conforms to the moisture requirment of 12 to 19% range, it should comply with the hardness requirment of 75% , ett for micro laryngeal surgery : 4,5 & 6mm used for vocal cord surgery the smaller diameter of tube allow the surgeon an easier view an access to vocal cord 22 mm standard female connector on both the ends with in a diameter of 15 mm elbow port for easy suctioning, sterile disposable, individualy pack, it should have low pressure large volume & large diameter cuff, enotracheal tube holder : adjustable straps latex material with integrated bite block with ett holding screw & band for fixation, inj: adrenaline 1 mg, breathing circuit holder: adult/paediatric breathing system tube support 30mm/22mm/15mm slots flexible neck, non disposable, 15inch length, pvc material , i.v. infusion set: advanced fluid administration system- protective cap with prime stop membrane, bacterial retention air vent & air stop- with 15 micron fluid filter in the chamber, medical grade, non-toxic dehp free transparent kink free tubing 180 cm , parking space in roller clamp., alcohol hand gel: alcohol hand gel: 80% w/v ethanol + emolients and alkonium compound , alcohol swab: alcohol swab (single use): paper based swab impregnated with alcohol sufficent to swab and sterilize vascular acess site. packed in puncture proof water proof peel pack, cannula -arterial cannula (single use), sw 20 , 22: arterial cannula (single use), sw 20 , 22,made of medical grade platsic with ptfe / teflon coating. over the needle type. fitted with flow swtich. port for connecting infusion bag, arterial pressure monitoring line. , inj: atracurium besylate 10 mg./ml, chemical indicator : autoclave chemical indicator bowie & dick test pack , autoclave indicator label: autoclave indicator label (single use): indicator label roll of approximate size of postage stamp, changes color with temperature over 120c when exposed to steam under high

Central Government / Public Sector

CTN :36208390 Due date: 18 Jun, 202418 Jun, 2024 NA
Tender For supply of adjuster tube with guide bush conforming to rdso spec.no.07-abr-1992 amendment no. 5 of sept. 2016 to rdso drg no: wd-82064-s-05-rc, items - 4 & 5, alt : 7. [ warranty period: 36 months after the date of delivery ]

corporations/Associations/Others

CTN :36123290 Due date: 24 May, 202424 May, 2024 26.40 Lacs
Tender For corrigendum : supply of rdso core approved electrical items for trd - guy rod 9.3m , anchor loop , guy rod 9.7m , anchor v-bolt , bfb steady arm swivel , bfb steady arm hook , register arm eye-piece , tubular stay adjuster , tubular stay adjuster large , splice for 125 sq.mm catenary , catenary wire ending clamp , suspention clamp , contact wire dropper clip , contact wire swivel clip and swivel clip , catenary dropper clip , parallel clamp jumper , compensating plate , dropper clip 25mm dia , dropper clip 49mm dia , dropper clip 34mm dia , eqalizing plate , splice , 25mm drop bracket part , large register arm hook , tubular stay sleeve forged , double eye distance rod , guy rod double strap , single clevis , raised register arm adjuster , tube cap 40 mm , tube cap 25 mm , suspention clamp , 25 mm steady arm clamp assembly , p.g clamp , guy rod stirrup , large catenary suspention bracket , double suspention clamp , standard antiwind clamp , earth wire , feeder wire , pg clamp 50 sq.mm jumper 93.3 sq.mm anti creep wire bimettalic sleeve , flat armour tape , large span wire ending clamp 130 , armour tape ferrule , adjuster eye and clevis type , adjuster double clevis type

Central Government/Public Sector

CTN :36178228 Due date: 31 May, 202431 May, 2024 NA
Tender For supply of adjuster tube for slack adjuster type irsa-600 to rdso drg. no. wd-82064-s-05-rc alt.7 , item n o. 5.matl.&spec. as per drg. [ warranty period: 30 months after the date of delivery ]

Central Government/Public Sector

CTN :34200058 Due date: 15 May, 202415 May, 2024 NA
Tender For bid to ras bid to ras bid to ras supply of low load feed control valve - tag no.-fdv-14,1,4 inch ss tubing- 12 meter for each tag,ss fittings for connection to air filter regulator- for each tag,ss fittings for connection to air lock relay- for each tag,ss fittings for connection to ia header isolation valve - for each tag,ss equal tee - for each tag,ss 1,2 inch npt m x 1,4 inch od tube connector- for each tag,valve diagnostic and configuration software- for all tags,cv test charges for each control valve,gaskets-commissioning spares,gland packing-commissioning spares,mandatory spares-fdv14-critical control valve -pneumatic and electro-hydraulic actuator assembly,mandatory spares-fdv14-critical control valve -diaphragms, o rings, seals etc. of all types make etc.,mandatory spares-fdv14-critical control valve -solenoid valves if applicable,mandatory spares-fdv14-critical control valve- smart positioner units complete unit and accessories link assembly,mandatory spares-fdv14-critical control valve -pneumatic air-filter- regulator of each type,make ratin

Central Government/Public Sector

CTN :36154307 Due date: 24 Jun, 202424 Jun, 2024 NA
Tender For supply of adjuster tube for slack adjuster type irsa-600 to rdso drg. no. wd-82064-s-05-rc alt.7, item n o. 5. matl. & spec. as per drg. [ warranty period: 30 months after the date of delivery ] loco store depot bikaner, rajasthan

CTN :36141754 Due date: 21 May, 202421 May, 2024 NA
Tender For spare and amc of tyco sugar weighing machine - repair, overhauling and annual maintenance contract for tyco automatic electronic weighing & bagging machine for the crushing season 2023-2024., proximity switch assly. 24 vdc-npn, solenoid valve c/w coil 24 vdc, festo tube, air regulating valve assly., quick valve assly., brush with cage, leather belt for bag clamp, rubber pad for bag clamp, indicating lamp red/green 24 vdc, indicating lamp red/green 240 vac, sealing kit for load clamp cylinder 3 , sealing kit for load bucket cylinder 2.1/2 , sealing kit for coarse/fine cylinder 1.1/2 , aluminum t connectors with brass nozzle, cylinder assly. for bag clamp 3 x 100, cylinder assly. for coarse/fine 1.1/2 x 75, actuator coil for solenoid 24vdc, load cell (capacity 110 kgs.), relay unit, connection c/w nozzel for bag sport, brass nozzel size , display unit c-750 (mettler toledo), f.r.l. unit having 2 nos. bottles, auto/manual switch, n.o. element of push button, cylinder for mechanical load bucket, s.m.p.s., micro switch assly., nylon bearing, rod end bearing with holder pin, stud for load cell c/w nut, u profile element, load bucket (mechanical type) assly. c/w pneumatics contact part ms, bag spout assly. c/w pneumatics, contact part ms, master frame assly (feeder) c/w pneumatics for make sugar silo, cylinder for shutter (course/fine), fork for machanical cyl. with pin for pan door, regulator valve for shutter cyl., cylinder for bag clamp., pan door seal, ac 220 v, lamp, damp switch with no point, n.o. connector, machincal cylinder (l.b.), numetic pipe, l.max connector, machanical load bucket, control pannel of bagging machine, level sensor for sugar bin system, relay card 24 vdc, flow control valve, copper pipe

Central Government And Public Sector

CTN :36119448 Due date: 15 May, 202415 May, 2024 NA
Tender For supply of trolley mounted double acting grease pump of 50kg capacity as per the following specifications-( 1) pressure ratio-50:1(2) suction tube length: minimum 730mm. (3) suction tube diameter: minimum 30mm. (4) bucket capacity: 50kg. (5) flow rate minimum: minimum 1.10kg/min. (6) delivery hose length: above 2100mm (7) type of hose: wire braided oil resistance and high pressure (8) stroke: double (9) recommended working p ressure: 4.5kgf/sq.cm. to 10.5 kgf/sq.cm. (10) blocked pressure at 10.5kgf/sq.cm.: above 400kgf/sq.cm. (11) a ir requirement: above 300lpm (12) air inlet connection: minimum 1/4 inch (f) (13) pump outlet connection: mini mum 1/4 inch (f) (14) grease ratio: 50:1 [ warranty period: 30 months after the date of delivery ]
 Loading, Please wait...

Connect us via What's Up