Get complete information related to latest Aerial Work Platform Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Aerial Work Platform Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Aerial Work Platform Tenders.
Tender For supplying and erection of ht anchor bolt fastner of size m12 x 250 mm and m16 x 250 mm with elevated drilling in the pier/ concrete and epoxy solution for manufacuring and erection work of extension platform. ladders etc at ner dhamna (purna barrage - 2) project district akola
Tender For construction of rcc platform for 62.5 kva diesel generator set at air, kohima studio complex (foundation size 18 ft. length, 10 ft. width, 2.5 ft. height). a). bolder soling 300mm thick. b). brick wall 250mm around. c). 10mm m.s. rod, 100mm gap. d). rcc concrete 150mm thick. (m.15 ratio 1.2.4 with cement polishing.
Tender For custom bid for services - provision of standby pump and associatedworks at main water supply pump house at af station samana-1. supply, installation and commissioning of submersible pump set 30 hp having discharge of 1650-500 lpm and head 47-78m electric driven 415 v, tp suitable open well (outlet size for 80*65mm dia) supply and install complete inclusive of 20 meter long 25 sqmm 3 core flat submersible cable, chain for supporting and taking out set mounting arrangement. nos 01, 2. supply, install, testing and commissioning and testing factory made and tested (including cpri type test certified) lt feeder pillar box (kiosk) outdoor type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 hz ac supply system, all as specified and directed, having bus bar chamber with insulated copper bus bars 350 amps rating installed on porcelain insulators. the panel shall be dust and vermin proof, made of 3.15mm crca ms sheet 75mm x 30mm thick ms channel frame, duly powder coated finish. front opening type with aprons for cable entry with double door shitter and locking arrangement, danger plate and earthing terminal. the scope of work includes pcc foundation and provision of the following :- incoming (a) mccb 4 pole 200 amps, 36 ka, 415 v - 01 nos (b) bus bar aluminum strip 400 amp, 4 pole, for in comp supply - 01 nos (c) digital panel meter including cts - 01 no outgoing (a) mcb tpn 40 amp 6 ka, 415 v 50 hz - 02 nos (b) mccb tpn 80 amp 16 ka, 415 v 50 hz - 01 no (c) star delta starter panel with suitable thermal overload protection, sppr, overvoltage, overcurrent and surge protection for 30 hp - 02 nos (d) low water level motor cutoff sensor with wire 20 mtr - 02 nos (make gic or slect control pvt ltd.). each 01, 3. supply and fix pressure guage upto pn-40 rating all as specified and as directed by engineer-in-charge. each 10, 4. supply and fixing hdpe pipe 90 mm dia pn 16 pressure rating with connected items all as specified and as directed by engineer-in-charge. rm 15, 5. supply and fix, gi sluice valve confirming to is 13095, 100 mm (4 ) dia with flanges end v all as specified and directed by engineer-in-charge., 6. material and labour in replacement for construction of valve chamber of size 1200 x 900 x 900 mm deep dimensions (over all internal dimension) for sluice valve etc. with pcc foundation, pcc block masonry walls, plastering, pcc coping, white washing, mild steel chamber cover, painting to chamber cover including excavation and earth work in any type of soil complete all as specified below :- valve chamber shall be provided with the following specifications :- (i) cement concrete for foundation (1:4:8) type d2 using 40mm graded stone aggregate 150mm thick extended upto 150 mm beyond the outer face of block masonry. (ii) walls of valve chamber 200 mm thick with precast cement concrete (1:5:8) (using 20 mm graded stone aggregate) solid building blocks, setting in cm 1:6 complete. (iii) internal and exposed surfaces of valve chamber both concrete and block masonry surface shall be plastered with cm 1:4 15 mm thick finished even and smooth. (iv) 50 mm thick coping in pcc 1:3:6 type c1 over block masonry wall. (v) entire plastered surfaces shall be treated with 3 coats of white wash. (vi) chamber cover shall be of 6 mm thick fiber reinforced polymer (frp) sheet with 30 x 30 x 5 mm size angle iron frame with hold fast and locking arrangement. steel furface shall be painted with two coats of synthetic paint of first quality over one coat of red oxide primer. each 01, 7. supply and fix 100 mm non return valve conforming to is 13095, 100 mm (4 ) dia with flanges end all as specified and directed. each 02, 8. supply and fix galvanized iron heavy grade pn 16 rating y section with flanged end 2 openings 100 mm dia and one 180 mm dia with suitable flanges and bots flanges end v all as specified and directed. kg 25-msme exemption - yes | startup exemption - yes
Tender For construction of entrance concrete road and exist ramp work of existing car washing platform along with protection wall drainage system at hrader par ward no 7 under katwa municipality under 15th finance commission tied grant
Tender For hubballi division:- sw-i:- bagewadi station-raising and extension of platform no.01 to make high level of 560m length with cement concrete flooring at bagewadi station.sw-ii:-proposed construction of track machine rest house in chikkodi road, chinchili, sedbal and vijaynagar. sw-iii-provision of low cost platform shelters at bagewadi station. (maintenance period= 03 years)
Tender For jjm scheme in kathalia rd block under sepahijala district/ construction of cement concrete platform , g.i. post including necessary fittings attached to different dtw and sbdtw schemes for fhtc under the jurisdiction of ae ,
Tender For jjm scheme in kathalia rd block under sepahijala district/ construction of cement concrete platform , g.i. post including necessary fittings attached to different dtw and sbdtw schemes for fhtc under the jurisdiction of ae , d
Tender For jjm scheme in kathalia rd block under sepahijala district/ construction of cement concrete platform , g.i. post including necessary fittings attached to different dtw and sbdtw schemes for fhtc under the jurisdiction