Tender For supply of 1.5t 5 star split ac including green ac nominal marketing capacity as per bee sta r rating label (in ton): 1.5, technology of airconditioner :inverter ac variable speed, iseer (wh/wh) value s for compliance of green ac: not applicable for non green ac, rated voltage (in volts): 230 v, 1 phase, 50 hz, ac, unit mounting arrangement :indoor unit wall mount type, airconditioner compliance : ac, bee star rating of the product : 5, classification by function : cooling & heating (cooling and dehumidification during cooling mode), material of evaporator :copper, material of condenser :copper, ac machine warranty (in ye ars) :1, warranty on compressor (in years) :10 (for inverter ac)up to including 2 ton capacity, rated coolin g capacity (in watts) as peris:1391(part 2): 4750-5800, split airconditioner: conforming to is:1391 (part 2) latest, eco-friendly refrigerant: yes, refrigerant designation: r 32, refrigerant global warming potential (g wp): 675 (for r32), refrigerant ozone depletion potential is zero: yes, classification by function: cooling an d heating (cooling and dehumidification during cooling mode), heating capacity (in watts): 4750-5800, unit type: single split ( single indoor and single outdoor), compressor type: single split ( single indoor and sing le outdoor), compressor type: rotary type/dual or twin, material of evaporator: copper, material of conde nser: copper, material of air filter (on indoor unit): synthetic fibre, reusable air filter: yes, ac modes: turb o mode, auto clean mode, quiet mode, dry mode, eco saving, swing, timer, remote control features: time r ,fan speed control, on/off, additional features: sleep mode, auto off, auto restart, indoor temperature indicator, dust filter, auto air swing, virus deactivation technology,4 way auto air swing, nanotech coatin g on evaporator tubes, noise level: as per is:1391 (part 2) latest, environmental friendly paint: yes (paint does not contain heavy metals or their compounds include mercury(hg), lead (pb), cadmium (cd) and hexa valent chromium (cr), recycled plastic components: >80% by weight of total plastic components in produc t, marking on the split ac: as per cl.17.1.1 and as per cl.17.1.2 of is:1391 (part 2), mode of packing: packe d with recycled and biodegradable material, supply cord and the inter connecting cord between the indoor and outdoor unit: 1 m (pvc insulated sheathed cables as per is:694), accessories / installation kit with each split airconditioner: 3m cu connecting pipe (for wall mount type up to 2 ton),remote control, operating m anual, installation manual, no installation kit, warranty card- ac machine warranty (in years): 1, warranty on compressor(in years): 10 (for inverter ac) up to including 2 ton capacity, availability of type test report from govt. lab/nabl accredited lab /ilac accredited lab to prove conformity of the specification: yes. as pe r is:1391 (part 2) latest, test report number and date - must declare: nabl, agreed to furnish all the test re ports and certificates to buyer on demand: yes. refrigerant pipe of min 3 meters including min connecting cable of 3 mtrs, drain pipe and suitable ms stand (powder coated) along with nut and bolt for fixing outdoo r unit. [ warranty period: 12 months after the date of delivery ]
Tender For supply of ml and tp , ml for cleaning , repair maint ac , ml taking dwon defective ac unit , repair maint ac , taking down defective compressor , sf temperature sensor probe , sf pcb board , sf non functional pcb board , sf repair running capacitor , sf repairs starting capacitor , sf repair indoor outdoor unit , sf repair delivery discharge valve , sf repairs copper tubing , sf repairs insulation copper tubing , supply and filling , taking down indoor fan motor , taking down out door fan m&l ,t&p for servicing of the split ac/tower/window ac 1.5/2.0/3.0/4.0 ton capacity of any make ,including oiling/greasing the blower motor, cleaning the evaporator condenser coils externally to remove the dust, replacement of defective thimbles, proper connections of wires etc and re-fixing the airconditioner at its origional position by the experienced ref mech all as directed by engr-in-charge (note :- (i) any u/s items other than specified above need to be replaced/gas charging etc shall be replaced & paid under seperately respective items.(ii) servicing of split type ac of capacity 1.5/2.0 tr capacity of any make by washing the outdoor unit condenser coil with soap water jet followed with clean water jet and indoor unit with the help of blower, wipe and clean the unit with dry cloth, complete all as specified and directed by engg-in charge., m & l for cleaning / flushing out the refrigeration system thoroughly with ctc, leak testing with co2 / n2 locating and rectifying the leaks by brazing with silver / copper rod, pressure testing, vaccumising and charging with refrigerant gas and topping up compressor oil, testing and commissioning complete for split type acs of 1.5 ton capacity complete all as specified and as directed. (note : (i) the quoted rate shall deemed to be inclusive of refrigerant gas (r-32/r-22/r-410a/r-134a) (ii) unit quoted rate shall deemed to be inclusive of ) /bid number : gem/2025/b/6331577 * /dated: 04-07-2025 & & / bid document 1 / 27
Tender For supply of split air-conditioner of bee 5-star rating, suitable for cooling capacity for the whol e range of 5201 to 6860 2 ton w (2 ton) with the function of cooling only, with rotary compressor, invert er (variable speed) type, suitable for 230 v ac, 50 hz system, with 100% copper coil, eco friendly refriger ant, anti-freeze thermostat, with thermal protection for blower motor & condenser motor. conforming to bi s specification no. is:1391 (part-2) 2023. bee 5-star rating must comply to ministry of power notification no . s.o. 3897(e) dated 29th october 2019 for table 3.2(f) with minimum indian seasonal energy efficiency r atio of 5.0 (applicability date extended by notifications no. s.o. 4485(e) dated 10th december, 2020 and n o. s.o. 4634(e) dated 10th november, 2021). complying to ministry of power notification no.s.0. 2528(e) d ated 8th august 2017 for other requirements. refrigerant copper pipes (suction & return) of minimum 4-m eter length each, nitrile rubber tube with density 55 kg/cubic meter or more, fire performance class 1, ra te of burning class v-0, water vapour diffusion resistance factor (i) more than 12000, service temperature 10 to 105-degree c, surface flame spread class 1 & thickness of minimum 2 inch, relevant test certificates to be submitted. nitrile rubber tube shall be with suitable inner diameter to suit & to wrap the complete le ngth of refrigerant copper pipe and aluminium foil lamination of 0.2 mm thick to cover entire length of the copper refrigerant pipes will be supplied along with each air-conditioner. make- daikin/ lg/ carrier/ blue st ar/ godrej /hitachi/lloyd, voltas/samsung or similar. [ warranty period: 30 months after the date of deliv ery ]
Tender For supply of airconditioner - item1 blue star invertor airconditioner 2 ton capacity 3 star copper 100 percentage , item2 blue star invertor airconditioner 2 ton capacity 3 star copper 100 percentage , warranty 1 year from product, 5 years for compressor , stabilizer , installation charges
Tender For corrigendum : purchase of machinery and equipment (13 m and e items) under the state schemes. - purchase of machinery and equipment (13 m and e items) under the state schemes., refrigeration & air conditioning technician(air-conditioning, direct system (complete with all controls including humidity control)), refrigeration & air conditioning technician(air-conditioning, indirect system (water cooled )), refrigeration & air conditioning technicianl(cassette airconditioner 4500 kcal/hr), refrigeration & air conditioning technician(evacuating and refrigerant charging station ), refrigeration & air conditioning technician(evacuating and charging station as above but fitted with weighing scale ), refrigeration & airconditioner technician(vrf/vrv unit with two indoor units 2.5tr each and 5tr capacity out door unit complete with air cooled condenser, accessories and controls.), refrigeration & airconditioner technician(walk in cooler puf insulated for cold room 6x4.5x8 cft. temperature 0 -5 c), refrigeration & airconditioner technician(package a/c 5- ton capacity, air cooled type with open type compressor reciprocating type), refrigeration & airconditioner technician(automatic ice cube m/c 50 kg/hour), refrigeration & airconditioner technician(bus ac tutorial model ), refrigeration & airconditioner technician(absorption system (small size) ), refrigeration & airconditioner technician(ice candy plant 2 ton with capacity to make 32 ice candy at a time), mechanic motor vehicle(air conditioning service unit (car))
Tender For supply of compressor for three phase emu cab airconditioner similar to emerson copeland make (mod el no-zr61kce-tfd-522) type-hermetic scroll , refrigrent-r134a, exhaust capacity-14 to 34 m3/hr, refriger ation capacity- 14600 w, 5 hp, maximum current-11 amps, voltage-3phase-380-420v/50hz, length x widt h x height-24.1x24.7x45.1 cm approx., discharge pipe diameter-1/2 inch and suction side nozzle diameter - 7/8 inch. of make m/s. emerson copeland or equivalent. [ warranty period: 30 months after the date of delivery ]
Tender For supply and installation of some articles to the residential office of the honble deputy speaker, tripura legislative assembly, bardowali, agartala during the year 2025-26 - providing of split type high wall 2.00 tr (rated cooling capacity should not be less than 6,000 kcal/hr or 24000 btu/hr or 7000 kw) split a.c. machine with inverter compressor technology operating on non-cfc refrigerant (r-410a/r-32/equivalent refrigerants) suitable for wall mounting conforming to is:1391 (part-ii) specification (evaporator & condenser must be of pure copper) not less than 3 (three) star rating (latest standard), operates on single phase 230 volt, 50hz, ac supply maximum current drawn 11.0 ampere, including supply of 3.0 mtr copper pipe (both for suction & liquid line), 3.0 mtr 4 (four) core electrical connecting cable, remote control unit in/c batteries, 16 amps power top etc complete, capable of performing a) cooling b) dehumidifying c) air circulation d) filtering as per direction of the engineer-in-charge., standard installation of 1.5 tr/2.00 tr capacity high wall split airconditioner i/c providing of electrical plug top of required capacity, flling up/ repairing of drilled portions by cement mortar, painting etc. as per direction of the engineer-in-charge., fabrication of m.s. platform for placement of condensing unit by using m.s. angle of (50x50x5) mm size base plate, nuts & bolts or cradle of suitable sizes i/c painting, fitting, fixing grouting by cement mixer as per direction of the engineer-in-charge., providing hard pvc pipe of best quality of 25 mm diameter including necessary clamping and fitting for draining of condensate water from indoor unit as per direction of the engineer-in-charge., supply and installation of additional length of copper pipe of suitable diameter for suction and liquid line between indoor and outdoor units (for 1.5 tr & 2 tr ac) beyond the standard length as per direction of the engineer-in-charge. (if required), providing and connecting electric control cables between mcb to indoor/outdoor. 3c x 2.5 sq. mm copper cable., supplying & fixing of 1200 mm sweep white color ac ceiling fan capacitor type double ball bearing complete with 300 mm down rod, canopies, shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm pvc insulated copper conductor cable(fr) (isi marked, bee 1 star/minimum service value 4.0 m /min/w): -, supplying and fixing of 20 mm dia extra down rod (gi pipe medium guage) with necessary hole for installation of ceiling fan as required., wiring for light/fan/ exhaust fan/ call bell point with 2x1.5 sq. mm pvc insulated copper conductor cable (fr) in pvc conduit (medium gauge) recessed in slab/ walt complete with 6/10 amps modular type switch, cover plate, gl box including necessary connection etc. as required, supplying and fixing of the following modular accessories including necessary connection etc. as required 3/6 pin 16/20 amps socket outlet (2m), supplying and fixing of the following modular accessories including necessary connection etc. as required4 step fan regulator (1m), supplying and fixing of the following modular accessories including necessary connection etc. as required20/25 amps single phase motor starter switch (2m), wiring for circuit/sub-main with the following sizes pvc insulated copper conductor cable (fr) in pvc conduit (medium gauge) recessed in slab/ wall etc. as required, earthing with 40 mm dia g.i. earth pipe (medium gauge) 4.5 m. long complete with masonry enclosure on top cl cover plate size 12"x 12" having locking arrangement including cc work, holes on earth pipe etc. as required, proving and fixing/drawing of 4.06 mm dia (8 swg) g.i. 10 wire on surface or in existing g.j/pvc/ polythene pipe for loop earthing as required., executive desk with return unit, size: 2100(w)x 2250(d) x 750 (h) mm, executive revolving chair, visitor chair, godrej 4 door bookcase (1742 h x 914 wx 320 d) mm