Tender For repair and overhauling service - upgradation of gym interior of officers gym; interior design; yes; buyer premises: augmentation of interior designing for officers' gymanisum -ins vishw rma-1 false ceiling-providing and fixing suspended false ceiling of armstrong or equivalent (fine fissured micro look with silhouette grid) equivalent of size 600mm x 600mm at all levels fixed with channels & hanger rods & making cut outs for all led lights etc including all material, labour and transportation as per approved sample designs, drawings and specifications as directed by the officer in-charge. item includes dismantling of old ceiling and disposal of the malba. providing ducting after making necessary connections from the main duct . the work has to be executed in co-ordination with the air conditioning system agency and with the officers monitoring the ac system 2) wooden ceiling providing of faux beams in the ceiling as part of the design of the false ceiling. beam size shall be 8" x 8" as per texture and colour finalized . the installation has to be carried out maintaining the aesthetics of the area and as per design finalized including all material, labour, transportation as per approved sample designs, drawings and specifications as directed by the buyer 3) electrical wiring : providing & fixing of 25mm electrical conduits of make akg/polypack/setia or equivalent making chasing in walls & finishing it with plaster making it good for painting & pvc insulated copper wires of finolex/havells or equivalent as per approved samples, design, drawings, specifications & as directed by the buyer, item includes removal of the old wiring and disposal of the malba 4) light fixtures downlighters : providing & installation of led downlighters of 5000k of reputed brand jaguar/philips/legero/syska as per approved samples, design, drawings, specification and as directed by the buyer with testing and commissioning. item includes dismantling of old lights and buy back of old lights with fittings and disposal of all malba 5) track lights & spot lights spot lights : providing & installation of 9w cob lights of reputed brand jaguar/philips/legero/syska as per approved samples, design, drawings, specifications and as directed by the buyer 6) magnetic track lights : providing of suspended magnectic tracks of reputed brand philips/jaguar/ legero/syska or equivalent including 200w integrated power supply, trimless wall corner l jointer for magnetic track channel and hanging kit set. providing of 20w linear laser tiltable spotlight with a combination of cone pendant light as per approved samples, design, drawings, specifications and as directed by the buyer 7) switches/sockets & switch boards providing of switches sockets and all the switch boards of reputed brand i.e. schneider/norisys as per approved samples, design, specifications and as directed by the buyer 8) ceiling and wall painting cleaning and sanding of the surface of the ceiling and wall and application of 1st coat of oil base primer. upon drying of primer, application of 2 coats of birla wall putty. upon drying, sanding the surface to a smooth seamless finish and application of 2nd coat of oil base primer. upon dring of the primer application of 3 coats of emulsion of royale teflon finish as per approved samples, specifications and as directed by the buyer 9) wall panelling providing and fixing in position wall panelling at all heights with pvc wall panel/sheets (5-9mm thickness) of approved texture, design and patterns having nrc (noise reduction co-efficient) of 0.50 (minimum), light reflectance of 85% (minimum). non combustible fire performance as per bs:476 , humidity resistance of 100% , thermal conductivity <0.043 w/m k comprising of frame made in the wall from specially fabricated galvanized mild sheet 0.50mmthk pressed section (galvanizing @120grams per sqm including both sides) i.e. vertical studs of size 48 x 34 x 36 fixed to the floor and sof
Tender For supply of ac spare parts - - copper pipe dia inch x 0.7 mm thickness x 50 ft. make: godrej /totaline/carrier/daikin/camipro , un-armoured frls pvc insulated 2.55q. mm, 4 core flexible copper conductor as per is:694:2010 (100 m coil) make - havells / finolex/kei/ polycab 3 mfd capacitor (metal body), burst proof running capacitor for airconditioner application: a) voltage rating 440 v b) should be explosion proof c) built in pressure sensitive interrupter to be present in the capacitors d) terminals: tin plated e) material of construction entire body made up of aluminium with metal top make: tibcon / sarda/or equivalent isi marked , 4 mfd capacitor (metal body) burst proof running capacitor for airconditioner application: a) voltage rating 440 v b) should be explosion proof c) built in pressure sensitive interrupter to be present in the capacitors d) terminals: tin plated e) material of construction entire body made up of , aluminium with metal top make: tibcon/sarda/or equivalent isi marked. , 50 mfd capacitor (metal body), burst proof running capacitor for airconditioner application: a) voltage rating 440 v b) should be explosion proof c) built in pressure sensitive interrupter to be present in the capacitors d) terminals: tin plated e) material of construction entire body made up of aluminium with metal top make: tibcon/sarda/or equivalent isi marked. , gas charging pin inch diameter flare nut (brass) for air conditioning application 5/8 inch diameter flare nut (brass) for air conditioning application , ptc relay for godrej make refrigerator , ptc relay for lg make refrigerator , ptc relay for samsung make refrigerator , ptc relay for whirlpool make refrigerator , r-22 refrigerant cylinders (1 litre can) for air conditioning application, conforming to standard is-5610 :1983 with latest amendment. purity not less than 99% packing should be factory sealed in steel cylinder. make: godrej/floron/mafron / ecorane , universal remote for ac indoor unit. the remote should be ir compatible, battery powered, with operating distance minimum 8 meter make: phillips/ baba/godrej / carrier , strainer (copper application 0.5 mm thickness) for air conditioning , strainer (copper, 0.5 mm thickness) for refrigeration , aaa size alkaline battery with nominal voltage1.5 v, flat contact terminals as per iec - lr03 make: duracell/evaready/nippo , un-armoured frls pvc insulated 2.5sq. mm 3core flexible copper conductor as per is:694:2010 (100 m coil) make - havells / finolex / kei / polycab
Tender For running operation and maintenance of e and m installation at dvor bikaner - running , operation & maintenance of all internal & external e&m installations , installed at lunka-i as per inventory and as per scc , technical specifications by deputing following minimum manpower per day (on all days i/c sunday & other holidays but excluding weekly off) alongwith required t&p and sundries etc. complete as required and as per the direction of eic. (a) highly skilled (supervisor)- 01 no (b) skilled manpower - 03 nos. (c) helper - unskilled - 03 nos. , running , operation & maintenance of all internal & external e&m installations , installed at lunka-ii as per inventory and as per scc , technical specifications by deputing following minimum manpower per day (on all days i/c sunday & other holidays but excluding weekly off) alongwith required t&p and sundries etc. complete as required and as per the direction of eic. (a) highly skilled (supervisor)- 01 no (b) skilled manpower - 03 nos. (c) helper - unskilled - 03 nos. , annual comprehensive maintenance of 1.5 tr/ 2tr split type air-conditioning unit comprising of compressor , condensing coil unit , cooling coil unit , repair/ replacement of pcb card and defective component i/c comprehensive repair & maintenance of voltage stabilizer and time delay unit for above units etc. complete as required at lunka -i (rates job per unit per month). , annual comprehensive maintenance of 1.5 tr/ 2tr split type air-conditioning unit comprising of compressor , condensing coil unit , cooling coil unit , repair/ replacement of pcb card and defective component i/c comprehensive repair & maintenance of voltage stabilizer and time delay unit for above units etc. complete as required at lunka -ii (rates job per unit per month). , fuel cost i/c transportation , storage at site for running of the 30 kva , cummins make dg sets/hour/dg set basis (contractor has to quote his running cost of fuel/hour of running operation of dg set at lunka -i. , fuel cost i/c transportation , storage at site for running of the 30 kva , cummins make dg sets/hour/dg set basis (contractor has to quote his running cost of fuel/hour of running operation of dg set at lunka -ii. , carring out b-check of 30 kva dg set (cummins make) at lunka -i site by suppling & replacing of appropriate grade/oem recommended lub oil , fuel water separator , oil filter , air cleaner element , corrosion inhibitor (all spares shall be genuine and recommanded by cummins) required for b-check servicing including transportation , men & material cost and service charges etc. as per oem recommendation (servicing is to be carried out through authorised dealer only). , carring out b-check of 30 kva dg set (cummins make) at lunka -ii site by suppling & replacing of appropriate grade/oem recommended lub oil , fuel water separator , oil filter , air cleaner element , corrosion inhibitor (all spares shall be genuine and recommanded by cummins) required for b-check servicing including transportation , men & material cost and service charges etc. as per oem recommendation (servicing is to be carried out through authorised dealer only). , painting of electrical cubical panels , feeder pillers , marshalling boxes , desert coolers , street light poles etc. with 2 coats of enamelled paint of preferred make and colour etc. complete as required as per direction of eic. (lunka -i & lunka -ii) , carrying out complete health check up of dg sets ( as an when requried) by deploying company trained engineer/technician and submission of detailed report i.r.o. malfunctioning of any component including replacement of defective components etc. (only cost of spares will be borne by aai). for all labour cost , transportation , t&p etc. shall be responsibility of the agency. (lunka -i & lunka -ii) , to carry out work as per cpwd delhi schedule of rates (e and m) 2022 and as per cpwd specifications complete as re
Tender For supply of on/off rotary switch for air conditioning in lhb ac coaches rated voltage - 110v, rated current 6amps, position 2 , pole - 5 as per s. no. 58 of bill of material of rdso specn. no.rdso/pe/spec/ac/0184- 2015 (rev-1) suitable for use in switch board cabinet of lhb type ac coaches. [ warranty period: 30 months after the date of delivery ]
Tender For supply of auto manual bye pass,rotary switch for air conditioning, current rating- 16a, position-3 (auto, manual, off) ,no. of poles-7 as per sr. no. 57 of bill of material (bom) of rd so spec. no.rdso/pe/spec/ac/ 0184-2015 (rev-1). similar to l&t - salzer cat no. 16a-d16-61031-b 13-fhyr and confirming to rdso spec no. rdso/pe/spec/ac/0184-2015 (rev-1) . suitable for use in switch board cabinet of lhb type ac coaches make rdso approved: l&t - salzer [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ]
Tender For supply of auto manual bye pass, rotary switch for air conditioning current rating 16a, position-3 (auto manual off), no of poles-7 as per bill of material of rdso spec. no. rdso/pe/spec/ac/0184-2015 rev. 1 or latest similar to l&t- salzer cat no. 16a-d16-61031-b13-fhyr suitable for use in switch board cabinet of lhb type ac coaches. acceptable makes l&t/salzer/seimens.