Tender For deposit-replacement of 1 no. damaged 8.5tr compressor unit of ac installed in the ortho suite of emergency operation theatre attached to medical college hospital thiruvananthapuram-electrical ac work
Tender For corrigendum : supply of spares for blue star make air cooled ducted ac units installed at 1x800 mw unit no. 8 of wanakbori tps. - blower 270 o.d*260 lg gi part code bfcf-gif122-00 for 8.75 tr blue star make ductable split ac unit model no: dsa1052r2, handset-controller 2comp with sppr -dsa part code ec0596-0011 for 8.75 tr blue star make ductable split ac unit model no: dsa1052r2, fab-scroll 270 x 260 part code fbsc-gd002-00 for 8.75 tr blue star make ductable split ac unit model no: dsa1052r2, filter three flap dsa 1001 ia (464*403) part code fipr-dhd008-00 for 8.75 tr blue star make ductable split ac unit model no: dsa1052r2, motor-dc328t 1/2 hp 1000 rpm part code moac-f007016-12 for 8.75 tr blue star make ductable split ac unit model no: dsa1052r2, filter drier ek-083, make- blue star, part code- rcdr-083-00, emerson thermostatic expan valve 5tr part code rctxv-emer09-00 for 8.75 tr blue star make ductable split ac unit model no: dsa1052r2, 3/8 in shut off valve part code vasf-12d001-00 for 8.75 tr blue star make ductable split ac unit model no: dsa1052r2, fan blade 22 inch part code bfax-ald010-00 for 8.75 tr blue star make ductable split ac unit model no: dsa1052r2, comp-scroll-zr 57 kse-tfd 593 part code cmsca475k31202 for 8.75 tr blue star make ductable split ac unit model no: dsa1052r2, motor- 1/4 hp- 4 pole -900 rpm-fn11 part code moac-f002014-20 for 8.75 tr blue star make ductable split ac unit model no: dsa1052r2, pre control-acb2ub125-ceauto450psi6a part code rcpr-acb2ub125-00 for 8.75 tr blue star make ductable split ac unit model no: dsa1052r2, pressure control yk-01l 400-035g050g, part code: rcpr-lcb-da80-00 for blue star make package ac
Tender For bid to ras supply of 3. 75 kw ac drive , 7. 5 kw ac drive , 11. 0 kw ac drive , 22. 0 kw ac drive , 45. 0 kw ac drive , 75. 0 kw ac drive 3 phase, digital ac drive -3. 75 kw; input suppl:380 to 480v ac 10% ,3 phase, 3 wire, 50 hz; mode of control: bidirectional fully controlled 3-phase ac; speed regulation: 1 % of base speed through encoder feedback; braking: suitable dynamic braking unit and chopper unit (external or in-built); acceleration time: 0. 1 to 1000s or better; deceleration time: 0. 1 to 1000s or better; programmable control connections :- (i) two analog inputs :- two nos. analog inputs having signal voltages of 0 to 10 vdc or 4 to 20 ma (ii) two analog outputs : two nos. analog outputs having singal voltages of 0 to +/-10 vdc or 4 to 20 ma (iii) six digital inputs (iv) one relay output (v) two digital outputs; make: the drives should be siemens/ abb/ yasakwa/ mitsubishi/ schneider electric /hitachi /allen bradley(rockwell) /delta /toshiba /danfoss/ baumuller/ baldor/ fuji electric make only. , 3 phase, digital ac drive -7. 5 kw; input suppl:380 to 480v ac 10% ,3 phase, 3 wire, 50 hz; mode of control: bi-directional fully controlled 3-phase ac; speed regulation: 1 % of base speed through encoder feedback; braking: suitable dynamic braking unit and chopper unit (external or inbuilt); acceleration time: 0. 1 to 1000s or better; deceleration time: 0. 1 to 1000s or better; programmable control connections :- (i) two analog inputs :- two nos. analog inputs having signal voltages of 0 to 10 vdc or 4 to 20 ma (ii) two analog outputs : two nos. analog outputs having singal voltages of 0 to +/-10 vdc or 4 to 20 ma (iii) six digital inputs (iv) one relay output (v) two digital outputs; make: the drives should be siemens/ abb/ yasakwa/ mitsubishi/ schneider electric /hitachi /allen bradley(rockwell) /delta /toshiba /danfoss/ baumuller/ baldor/ fuji electric make only. , 3 phase, ) /bid number: gem/2025/b/7026087 * /dated: 20-12-2025 & & / bid document1 / 16
Tender For corrigendum : supply of cm of 1.5tr non inverter split ac units , replacement of blower fan motor in 1.5 or 2 tr ac unit , replacement of blower drum in 1.5 or 2 tr ac unit , replacement of condenser fan motor in 1.5 or 2 tr ac unit , replacement of condenser fan blade in 1.5 or 2 tr ac unit , pcb repair for indoor unit of 1.5 or 2 tr ac unit , pcb repair for outdoor unit of 1.5 or 2 tr ac unit , replacement of 1.5 tr rotary compressor in 1.5 tr ac unit , replacement of 1.5 tr rotary compressor in 2.0 tr ac unit , replacement of 25 or 35 mfdcapacitor in 1.5 or 2 tr ac unit , replacement of 2 pole 25 amp contactor for 1.5 or 2 tr ac unit , replacement of 4 or 6 way terminal box for 1.5 or 2 tr ac unit , water service for 1.5 or 2 tr ac unit , blower service for 1.5 or 2 tr ac unit , charging or topping up r22 or r134 gas in existing 1.5 or 2 tr ac unit , replacement of 50mm thick synthetic air filter for 1.5 or 2 tr ac unit , sitc of auto sequential micro controller for 2 no split or window ac units , replacement of faulty 25 a sp mcb in existing db for 1.5 or 2 tr ac unit , site visit for ac fuult clearing with minor repair
Tender For supply of supplying of 1. 5 tr inverter type 5star rated split ac unit , installation testing and commissioning of 1. 5 tr inverter type split ac unit , sf of powder coated heavy duty pre fabricated iron stand , supplying and fixing copper refrigerent pipe line , u pvc piping 25 mm dia 2 mm thick , supplying and fixing of following sizes of rigid u-pvc piping 40 mm dia 2 mm thick , s l of copper flexible cable 3 x 1. 5 sq mm , sl copper flexible cable 3 core 2. 5 sq mm , dp along with 25 to 32 a 240 v c curve dp mcb , s f 5 amps to 32 amps 240 volts single pole c curve mcb
Tender For supply of airconditioning system spares for bd355 dozers at lingaraj ocp c c - condenser-3 fan,part no-rd47084 , hvac unitrooftop,part no-r9570 , ac unit,part no-r9758 , condenser,part no-r6260 , motor-double blower, 24 v,part no-rd588380p , fan motor assy 10 in dia 24 v,part no-rd587031 , fan motor assy 24v,part no-rd586276p