Tender For annual routine and maintenance operation of various equipments like ei installations, vrv/vrf, access control system, flap barriers, r/o water cooler, airqualitymonitoringsystems for the year 2024-25 of defence office complex, africa avenue (a, b block) and kg marg, new delhi. (sh: annual comprehensive maintenance of access control system including flap barriers installed at doc, africa avenue and kg marg).subwork/packages:annual routine and maintenance operation of various equipments like ei installations, vrv/vrf, access control system, flap barriers, r/o water cooler, airqualitymonitoring system for the year 2024-25 of defence office complex, africa avenue (a, b block) and kg marg, new delhi. (sh: annual comprehensive maintenance of access control system including flap barriers installed at doc, africa avenue and kg marg)
Tender For supply of supply of 5mp outdoor bullet motorized zoom lens camera , supply of 2mp indoor fixed dome motorized zoom lens camera , supply of 5mp indoor compact dome ptz motorized , supply of 2mp outdoor dome ptz 40x motorized optical zoom lens camera , supply of rack mountable 16 channel nvr with , supply of surveillance grade 8 tb sata hard disk , supply of nvr video management software application , supply of 1tb external hard drives , supply of 16 port layer-3 managed ethernet network switch , supply of 16 port layer-2 managed ethernet network switch , supply of 8 port layer-2 din rail type managed ethernet network switch , supply of 1g duplex sfp module , supply of 55 inch commercial grade display , supply of 32inch monitor to connect with nvr video output , supply of workstation with antivirus , supply of indoor floor mount 15u rack with pdu , supply of outdoor ip67 metal junction box , supply of cat6 u, utp lszh ethernet lan cable , supply of sm 3 meters lc- lc fibre patch cord , supply of 5 mtrs 4k resolution hdmi cable as per the detailed specifcations , supply of 2 inches width pvc casing capping as per the detailed specifcations , supply of 25mm diameter pvc conduit round type as per the detailed specifcations , supply installation testing commissioning of 40mm hdpe pipe as per the detailed specifcations , supply of 3 core 1.5 sq mm flexible power cable as per the detailed specifications , supply of biometric device both finger print and card access , supply of em door lock with leaf 600lbs , supply installation testing commissioning of exit button , supply of biometric access card , supply of enrollment kit , supply of biometric and access control management software application , supply of biometric and access control management server , supply of erection testing commissioning of 6 meters outdoor frangible pole , supply of 4kva power surge protection as per the detailed specifications , supply of ethernet surge protectors as per the detailed specifications , supply of 6 sq mm earthing cables with suitable fixing lugs as per the detailed specifications , excavation of soft and hard soil digging and refilling 500mmhx300mmw , road cutting,platform,pedestrian cutting and refilling with concrete for installation of gi, hdpe pipes , training and documentations , installation testing and commissioning , 1st year camc for s. no 1 to 35 , 2nd year camc for s. no 1 to 35 , 3rd year camc for s. no 1 to 35
Tender For (1)supply of high availability single section digital axle counters(hassdac) with dual sensor system as per rdso spec. no:rdso/spn/177/2012 (ver.3) with dual track sensor device or latest amended up to date of tender opening. this includes the supply of high frequency web mounting type tx coil/rx coil- 04 nos., vr/pr box duly wired-02 nos., vital relays-04 nos., pr relays- 04 nos., clamp with deflector plates & hardware- 08 nos., dual display reset box with auto resetting facility- 02 nos., surge voltage protection d evices and filter card to be mounted on din rail etc- 02 nos. for complete installation & testing & commissio ning of (hassdac) system. note: one set of hassdac system will include equipment required to monitor one up line or one dn line of a full block section between two stations. (2) installation, testing & commissi oning of high availability single section digital axle counter (hassdac), single section type system complet e with track devices and other associated accessories to be ensured by oem. this include fixing of device, r elays, wiring, lacing/dressing, cable termination with lug eyelet, drilling holes in rails, installation of track d evices and make it functional along with existing ufsbi/block instrument. material required other than supp ly item of hassdac in item no. 1 above shall be arranged by firm to make it functional. [ warranty perio d: 30 months after the date of delivery ]
Tender For corrigendum : procurement of the surge arresters (198kv, 10ka) comprising of metal oxide elements housed in frp cage duly moulded with silicon polymer along with insulated base and surge monitor to be used at 220kv sub station, ljhes, atmakur.
Tender For supply of point to point rf link , power over ethernet injector , ethernet lightening surge protector , stp cat6 cable , 8 port fxo telephone voip gateway , 8 port fxs telephone voip gateway , managed l2 switch with 12 ethernet ports and 4 fully loaded dual fibre sfp ports , managed l2 switch with 12 ethernet ports and 12 fully loaded dual fibre sfp ports , desktop computer with led monitor , serial to ethernet ip converter , lc lc style sm duplex patch cord , rj45 connectors field terminate plug , equipment rack 12 ru , lan cable tester , lan io crimping tool crimping tool , sitc
Tender For corrigendum : construction of 220 160 mva and 132 kv 50 mva gss at hindore rajiasar distt sriganganagar in rajasthan including survey supply of all smaterials erection including civil works testing and commissioning turnkey project - main material/ items, circuit breakers, 220 kv circuit breakers, 220kv circuit breakers (3 ph.) along with support structure, 2500 a, 50 ka, 132 kv circuit breakers, 132 kv circuit breakers (3 ph.) along with support structure, 1250 a, 40 ka, 33 kv circuit breakers, 33 kv circuit breakers (3 ph.) along with support structure, 1250 a, 25 ka, instrument transformers, capacitor voltage transformer, single-phase, 220 kv, 4400 pf cvt, single phase 132 kv , 4400 pf cvt, 33 kv potential transformer, 33/ 3 kv /110-110 3, current transformer (1-phase), 220 kv ct, 1000/1 a, 5c, 132 kv ct, 1000/1 a, 3c, 500/1 a, 3c, 33 kv ct, 1000/1 a, 4c, 500/1a, 2c, c&r panels & sas system (complete in all respect, refer section-v a, b, part-iii, volume-ii), new substation, control panel for 220 kv transformer (220 kv side) type: sas-thcb, relay panel for 220 kv transformer (for both hv & mv) type: sas-thrb, control panel for 220 kv feeder type: sas-fcb, relay panel for 220 kv feeder type: sas-frb, control panel for 220 kv bus coupler type: sas-bccb, relay panel for 220 kv bus coupler type: sas-bcrb, 220 kv busbar protection relay panel type: sas-bbrb, control panel for 220 kv transformer (132 kv side) type: sas-tlcb, relay panel for 220 kv transformer (132 kv side) type: sas-tlrb, control and relay panel for 1x 50/31.5/25 mva, 132/33 kv power transformer type sas-tcra, control panel for 132 kv feeder type sas-fca, relay panel for 132 kv feeder type sas-fra, control and relay panel for 132 kv bus-coupler type sas-bcra, control and protection panel for 33 kv feeder (i/c, o/g)/bus-coupler/ capacitor bank [for twin feeder/bay] type-fcrd, station hmi [industrial grade computer with 21"tft monitor as per specification requirements], station hmi (hot standby)[industrial grade computer with 21"tft monitor as per specification requirements], hmi view node[industrial grad computer with 21"tft monitor as per specification requirements], a3 size b&w laser printer, substation automation system network panel type sas-nw, modems (both sending and receiving end) for communication to rcc & sub sldc for plcc], data concentrator unit (dcu) at substation for ras mounted in suitable enclosure & fully wired, software: application as well as system software as per specification requirements for various hardware elements for meeting of functional requirement of the specification., substation auxiliary monitoring panel type sas-samp, other items:, fiber optic cables, connectors, ethernet cables, jack panels connectors, patch cords etc. for completing the substation lan as per specification requirements., transducers, sensors etc. (if not considered in the respective equipment/ items) for accumulating monitoring data as per the specification requirements for switchyards., surge arresters, 220 kv la, 132 kv la, 33 kv la, substation lt transformer, 33/ 0.433 kv, 250 kva lt transformer complete with all accessories, fittings, terminal connectors etc as specified filled with transformer oil, batteries & battery charger, batteries (sizing shall be as per requirement of technical specification), 220 v [min. 600 ah], 48 v [min. 600 ah], battery charger system, 220 v float and boost, 50 v float and boost, lighting system, outdoor lighting & other works, lighting fixture type fl-1, lighting fixture type fl-2, outdoor receptacle, type-rp, type-ro, substation premises lighting, lighting poles, type-l1, type-d1, street lighting type-sl-l1 for mounting on poles, street lighting type-sl-d1 for mounting on poles, sub-lighting boxes/panels type -slp at lighting mast and other loaction as designated complete with all controgears and accessories, items etc., lighting panel type acp-2 as per technical specification, lighting panel typ
Tender For corrigendum : construction of 220/132 kv, 1x160 mva and 132/33 kv, 1x40/50 mva gss at 220 kv gss kolayat (distt-bikaner) in rajasthan including survey, supply of all equipments/materials, erection (including civil works), testing and commissioning (turnkey ) - main material/ items, circuit breakers, 220 kv circuit breakers, 220kv circuit breakers (3 ph.) along with support structure, 2500 a, 50 ka, 132 kv circuit breakers, 132 kv circuit breakers (3 ph.) along with support structure, 1250 a, 40 ka, 33 kv circuit breakers, 33 kv circuit breakers (3 ph.) along with support structure, 1600 a, 31.5 ka, instrument transformers, capacitor voltage transformer, single-phase, 220 kv, 4400 pf cvt, single phase 132 kv , 4400 pf cvt, 33 kv potential transformer, 33/ 3 kv /110-110 3, current transformer (1-phase), 220 kv ct, 1000/1 a, 5c, 132 kv ct, 1000/1 a, 3c, 500/1 a, 3c, 33 kv ct, 1000/1 a, 4c, 500/1a, 2c, c&r panels & sas system (complete in all respect, refer section-v a, b, part-iii, volume-ii), new substation, control panel for 220 kv transformer (220 kv side) type: sas-thcb, relay panel for 220 kv transformer (for both hv & mv) type: sas-thrb, control panel for 220 kv feeder type: sas-fcb, relay panel for 220 kv feeder type: sas-frb, control panel for 220 kv bus coupler type: sas-bccb, relay panel for 220 kv bus coupler type: sas-bcrb, 220 kv busbar protection relay panel type: sas-bbrb, control panel for 220 kv transformer (132 kv side) type: sas-tlcb, relay panel for 220 kv transformer (132 kv side) type: sas-tlrb, control and relay panel for 1x 40/50 mva, 132/33 kv power transformer type sas-tcra, control panel for 132 kv feeder type sas-fca, relay panel for 132 kv feeder type sas-fra, control and relay panel for 132 kv bus-coupler type sas-bcra, control and protection panel for 33 kv feeder (i/c, o/g)/bus-coupler/ capacitor bank [for twin feeder/bay] type-fcrd, station hmi [industrial grade computer with 21"tft monitor as per specification requirements], station hmi (hot standby)[industrial grade computer with 21"tft monitor as per specification requirements], hmi view node[industrial grad computer with 21"tft monitor as per specification requirements], a3 size b&w laser printer, substation automation system network panel type sas-nw, modems (both sending and receiving end) for communication to rcc & sub sldc for plcc], data concentrator unit (dcu) at substation for ras mounted in suitable enclosure & fully wired, software: application as well as system software as per specification requirements for various hardware elements for meeting of functional requirement of the specification., substation auxiliary monitoring panel type sas-samp, other items:, fiber optic cables, connectors, ethernet cables, jack panels connectors, patch cords etc. for completing the substation lan as per specification requirements., transducers, sensors etc. (if not considered in the respective equipment/ items) for accumulating monitoring data as per the specification requirements for switchyards., surge arresters, 220 kv la, 132 kv la, 33 kv la, substation lt transformer, 33/ 0.433 kv, 250 kva lt transformer complete with all accessories, fittings, terminal connectors etc as specified filled with transformer oil, batteries & battery charger, batteries (sizing shall be as per requirement of technical specification), 220 v [min. 600 ah], 48 v [min. 600 ah], battery charger system, 220 v float and boost, 50 v float and boost, lighting system, outdoor lighting & other works, lighting fixture type fl-1, lighting fixture type fl-2, outdoor receptacle, type-rp, type-ro, substation premises lighting, lighting poles, type-l1, type-d1, street lighting type-sl-l1 for mounting on poles, street lighting type-sl-d1 for mounting on poles, sub-lighting boxes/panels type -slp at lighting mast and other loaction as designated complete with all controgears and accessories, items etc., lighting panel type acp-2 as per technical specifica