Get complete information related to latest Al Conductor Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Al Conductor Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Al Conductor Tenders.
Tender For supply of isi marked weather proof unarmoured pvc insulated and pvc sheathed single core cable 10 sq.mm (7 strands) for electrical powe r and lighting with stranded aluminium conductor for working voltage upto and including 1100 volts and conforming to is 694/1990(reaffirmed 2005). conductor shall conform to table 1 and table-ii as applicable to is:8130/1984(reaffirmed 2005). [ warranty period: 30 months after the date of delivery ]
Tender For supply of pvc insulated armoured unscreened undergrounds aluminiun conductor railway powe cable as per rdso spec. irs s:63/20 14 rev 4. & is:1554 part-i size 2 core x 25 qs.mm [ warranty period: 30 months after the date of delivery ]
Tender For supply of aluminium conductor welding cable (hofr covering) cable size:95 mm square, rated c urrent in amperes at 60 percent duty circle:438a, min. weight of conductor/mtr length of cable: 253.90 gms to is:9857/1990[first revision ]
Tender For supply of 1 core 120 sq mm 11kv earthed armoured ht power cable stranded comp-cir cular aluminium conductor screen with extruded semi conducting compound xlpe insulated and insul ation screening with extruded semi conducting compound in combination with copper tape, cores laid up inner-sheath of pvc sheathed cable, al flat strip armoured, conforming to is: 7098 (part-li) 1985 or latest amendments. make- kei, havells, finolex, polycab, rr kabel, glostar [ warranty period: 30 m onths after the date of delivery ]
Tender For supply of pvc flat cable, aluminium conductor with pvc insulation and sheath as per is 694 (q3) , led batten (q2) , molded case circuit breakers (mccb) as per is / iec 60947 (q3) , self ballasted led lamps for general lighting services (v2) conforming to is 16102 (q2) , mcb - miniature circuit - breakers for a.c. operation as per is / iec 60898 (part 1) (q2)
Tender For tender for supply of lt ug armoured cable xlpe , led down light , batten integreted led light , led street light , cable pvc copper conductor , bulb led , lt ug armoured cable xlpe , offload change over switch , onload change over switch , offload change over switch , power contactor , switch socket , mcb , offload change over switch , mccb , mccb , offload change over switch , cable pvc aluminum conductor , led tube light , gate valve
Tender For supply, installation, testing and commissioning of various electric item on annual rate contract - supply of din rail mounting contactor and accessories confirming to iec 61095 with following description and configuration in existing distribution board / sheet including making connections, testing etc. as required.oem shall have submit nabl / cpri / erda accrediated lab type test reports & all as per pre approved by engineer in charge.for additional technical parameters of product / work refer annexure a attached with this bsr modular contactor 40a - 3no, supply of wiring for sub mains isi marked (is:694) 1100 volts grade pvc insulated flat twin core sheathed solid aluminium conductor as required. for additional technical parameters of product / work refer annexure a attached with this bsr4.0 sq.mm, 6.0 sq.mm, 10.0 sq.mm, supply of mechanical / digital time switch having following day / week programme and minimum 100 hours reserve and ac1 rating of 16-20 mperes including making connection, programming conforming to iec 0730-1 and 60730-2-7 etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products/ work , refer exure "a" attached with this bsr.one day & week reserve (analog type ), one day & week reserve (digital type ), supply of 240/415 v ac mcb with positive isolation of 10 ka breaking capacity (b/ c/d tripping characteristic as per type of load and site requirement) 4 kv impulse withstand voltage, isi marked is 8828(1996) / conforming to iec 60898-1 2002, iec 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per iec, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , ip 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 a rating and 10,000 upto 63 a, 5000 for 80 a & above rating including making onnections, testing etc. as required. oem shall have submit nabl / cpri / erda accrediated lab type test reports & all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr. single pole mcb (with b/c curve tripping characteristics) 0.5 a to 5 a rating, 6 a to 32 a rating, 40 a rating, 63 a rating, providing & fixing of 240/415 v isolator isi marked is:13947- iii/conforming to iec 60947-3, suitable for ac22a utilization category, 4kv impulse withstand voltage, true contact indication, red colour dolly / lever shall have single mould covering overall poles for operation , two position din rail mounting, minimum phase termination capacity of 35sq.mm. ip 20 contact protection and fitted in existing distribution board / sheet including making connections, testing etc. as required. oem shall have submit nabl / cpri / erda accrediated lab type test reports & all as per pre approved by engineer in-charge.for additional technical parameters of product / work refer annexure a attached with this bsr. double pole isolator 30 a / 40 a rating, 63 a rating, triple pole isolator 40 a rating, 63 a rating, sitc of single stage, water cooled, high speed (2880 rpm), horizontal, centrifugal, openwell submersible pumps set pre filled with coolent water and fitted with mechanical seal - t/c vs t/c, thrust bearing shall be of carbon + s.s.the stator body of single phase pump shall be of ss and rest of all shall be of cast iron. all casting parts should be cathod electro deposition (ced) coated and other construction material should be confirming to is : 14220: 2018 . the overall performance of pump shall confirm to bee energy efficiency level of 3 star. valid bee certificate from oem must be submitted for the same. motor should be ie2 class as per iec 60034-2-1: 2007, iec 60034-30: 2008, & is12615:2011, including making connection etc as required complete in all respect. oem shall have submit nabl / cpri / erda accrediated lab type test certificate before executio