Tender For supply of speed control of converter fed dc motor setup,speed control of chopper-fed dc motor setup,dsp-based speed control of srm motor setup,ac voltage controller-based speed control of induction motor setup,vf control of three phase induction motor setup,microcontroller-based speed control of stepper motor setup,speed control of bldc motor setup,voltage regulation of three-phase synchronous generator setup
Tender For supply of radiator motor for lhb power car 3 phase squirrel cage induction motor 30 hp, 22 kw, voltage 415v +/- 10% , freq: 50 hz, rpm: 1460 , ip-55 , amb:50 degree celsius, pf:>/=0.8, efficiency: >/=89.9%, insulation class f suitable for 500 kva da set of cummins, greaves & koel make engines as per rdso spec no -rdso/pe/spec/ac/0084-2008 (rev-1) or latest . make abb model: m2bax180mlb4 imb3im1001 or similar model of siemens, kirlosker make or rdso approved with terminal connection suitable for star delta starter.
Tender For supply, installation ofautomobile lab equipments to government engineering college challakere - 4 - stroke, single cylinder, petrol engine test rig with electrical loading air cooled, v c r diesel engine test rig with electrical loading, 4-stroke, 3-cylinder, mpfi petrol engine test rig withhydraulic loading - water cooled with morse test facility, automotive exhaust 5 gas analyzer(petrol& diesel), tensile, shear and compression tests of metallic and non-metallic specimens using universal testing machine, speed control of dc shunt motor using igbt chopper with 1hp dc shunt motor, to perform speed reversal of dc shunt motor 1hp, voltage frequency control 3 ph induction motor with 1 hp ac motor power mosfet step up/step down chopper, determination of flash and fire point of fuels., determination of viscosity of oils using torsion viscometer., determination of viscosity of oils using redwood viscometer, determination of viscosity of oils using say bolt viscometer, determination of major and minor losses in pipe flow, performance testing of centrifugal fluid pump, performance testing of reciprocating fluid pump, performance testing of gear pumps fluid pump, performance testing of air blower, calibration of thermocouple, bevel protractor profile projector, toolmaker microscope
Tender For supply of radiator motor , for lhb type power car, 3 phase squirrel cage induction motor of 30hp/ 22kw, voltage 415v +/-10%, frequncy: 50hz, rpm-1460, ip-55, ambient:50 degree celsius, pf:>/=0.8, efficiency:>/=89.9%, insulation class- f, suitable for radiator of 500kva diesel generator set of cummins, greaves & koel make engines of lhb power cars, as per rdso specification no. rdso/pe/spec /ac/0084-2008(rev-1) with terminal connection, suitable for star delta starter. similar to abb make model no : m2bax180mlb4 imb3im1001.
Tender For purchase of tool and equipment in electrician trade in various itis under scdd - tool and equipment in electrician trade, contactor & auxillary contacts 3 phase, 415 volt, 25 amp with 2 no and 2 nc, contactor & auxillary contacts 3 phase, 415 volt, 32 amp with 2 no and 2 nc, limit switch - limit switch, liver operated 2a 500v, 2 contacts, rotary switch 16a/440v, relay- a.cut out relay 16a,440v, relay- b.reverse current 16a, 440v, relay- c. over current 16a,440 v, relay- d.under voltage 360v-440v, insulators including hardware fittings - pin type, insulators including hardware fittings - shackle type, insulators including hardware fittings - egg type, insulators including hardware fittings -suspension type, hydrometer, load bank ( lamp/ heater type) 6kw, 3ph, brake test arrangement with two spring balance rating 0 to 25 kg, laboratory type induction coil 1000 w, thermometer -digital 0-150 c, series test lamp 230v, 60w, knife switch dpdt fitted with fuse terminals 16 amp, knife switch tpdt fitted with fuse terminals 16 amp/ 440 v, miniature circuit breaker 16 amp, earth plate - 60cm 60cm 3.15mm copper plate,, earth plate - 60cm 60cm 6mm gi plate, earth electrode- primary electrode 2100 28 3.25mm, secondary cu strip 20 5mm, mccb - 100 amps, triple pole, elcb-25amps, double pole and 25amps, double pole, l n 30 ma, rccb-25amps, double pole and 25amps, double pole, l n 30 ma, fuses - hrc, fuses - glass, fuses - rewire type, rheostat (sliding type) - 0-25 ohm, 2a, rheostat (sliding type) - 0-300 ohm, 2a, rheostat (sliding type) - 0-1 ohm, 10 a, rheostat (sliding type) - 0-10 ohm, 5 a, capacitors - electrolytic, capacitors - ceramic, capacitors - polyester film, capacitors - variable, capacitors -dual run, various electronic components, various lamps - halogen, various lamps - incandescent lamp, various lamps - fluorescent tube, various lamps - hp mercury vapor lamp, various lamps - high pressure sodium lamp, various lamps - low pressure sodium lamp, various lamps - led, plug socket 230v, 5a, piano switch 230v, 5a, lamp holder 230v, 5a, cables:twisted pair, non -metallic sheathed cable, underground feeder cable, ribbon cable, metallic sheathed cable, multi-conductor cable, coaxial cable, direct-buried cable, bus bar with brackets (1 mtr each), rcc pole with accessories (ms angle iron, c-clamp, stay insulator etc.) and materials 6 mtr, safety belt standard quality, ohm meter;series type, 50/2000 ohm analog, ohm meter;shunt type 50/2000 ohm, digital multimeter, a.c voltmeter m.i analog, portable box type housed in bakelite case, milli voltmeter centre zero analog, portable box type housed in bakelite case (100-0-100 mv), ammeter mc analog, portable box type housed in bakelite case - 0- 500 ma, ammeter mc analog, portable box type housed in bakelite case - 0- 5a, ammeter mc analog, portable box type housed in bakelite case - 0- 25a, ac ammeter mi analog, portable box type housed in bakelite case - 0-1a, ac ammeter mi analog, portable box type housed in bakelite case - 0-5a, ac ammeter mi analog, portable box type housed in bakelite case - 0-25a, kilo wattmeter analog, digital wattmeter 230v, 1kw, 50hz, a.c. energy meter-single phase, 10a, 240v induction type, a.c. energy meter-three phase, 15a, 440v induction type, power factor meter digital 440v, 20a, three phase portable box type, frequency meter 45 to 55 hz, magnetic flux meter 0-500 tesla, lux meter- lux meter lcd read out 0.05 t0 7000 lumens with battery, tachometer -analog type-10000 rpm, tachometer -digital photo sensor type-10000 rpm, tong tester/clamp meter 0-100a (digital type), megger -analog -500v, 3- point d.c. starter for 2.5 kw dc motor, 4- point d.c. starter for 2.5 kw dc motor, wheat stone bridge with galvanometer and battery, single phase variable auto transformer 0-270v, 10 amp(air cooled), phase sequencer indicator 3 phase 415v, growler, ac starters: - for a.c motors of 2 to 5 h.p. - a. resistance type starter, ac starters: - for a.c motors of 2 to 5 h.p. dire