Tender For providing additional 1x8mva 66/11kv power transformer & construction of one no. of 66kv line terminal bay for terminating second circuit line at 66/11kv allimaranahalli sub-station in kanakapura taluk ramanagara dist., and making lilo arrangement to the existing 66/11v allimaranahalli sub-station by stringing 2nd circuit line from tap point of 66/11kv allimaranahalli sub-station on 66kv ramanagara-kanakapura sc line to 66/11kv allimaranahalli sub-station on the existing dc towers using coyote acsr conductor for a distance of 0.831kms. including supply of all materials/ equipment (excluding 8mva power transformer & 11kv switchgear) and erection (including civil works) of all materials/ equipments, testing and commissioning on partial turnkey basis
Tender For corrigendum : 15/edc(blp)/2026-27 - loading, unloading and safe cartage of the following materials from electricity store centre, balrampur to the work site/dump site (distance up to 50 km), st poles (11 mtr long), pcc poles (8.5 mtr long), acsr weasel conductor, lt abc 3x120+1x95+1x16sq.mm., 100 kva t/f, other line materials, erection of single st poles (11 mtr long) for 11 kv/l.t. line alongwith fitting of all accessories on pole including dragging of pole from dump site to pit site, erection of single pcc poles (8.5 mtr long) for 11 kv/l.t. line alongwith fitting of all accessories on pole including dragging of pole from dump site to pit site, erection of sectional double pole sectional pcc pole (8.5 mtr long pcc pole) alongwith fitting of all accessories on pole including dragging of pole from dump site to pit site., earthing of pole as per uppcl/resspo norms.., erection and grouting of stay sets alongwith complete fittings. cement, sand & brick ballast provided by the contractor at his own cost., grouting of poles with 1:4:8 cc ratio of cement, sand & brick ballast, backfilling of pits with mud completely.all required materials provided by the contractor at his own cost., laying, stringing, sagging & binding of conductors of 11 kv in 3 phase, 3 wire line with jumpering (where as required), laying, stringing & sagging of 3x120+1x95+1x16sq.mm. abc cable up to proper sag for the following size cable, construction of 11/0.4 kv s/s for 100 kva t/f with mounting and fitting of t/f on plinth/double pole with proper fitting of all acessories and connecting with all circuit including earthing of t/f fitting with all accessories., earthing of distribution t/fs for body & neutral upto water level with gi pipe of 1.5" dia. including gi strip size 35x6 mm. (all material will be supplied by contractor)., decentralized materials:-providing and fixing of following materials as per sanctioned estimate/package as per resspo u.p.p.c.l. drawing/ norms.(where is required)., suspension clamp with i hook, i hook, suspension clamp with i hook, i hook, lt fuse set., lt pvc cable al 1x120sq.mm., lt pvc cable al 1x400sq.mm., lug sutable for 250 kva, suspension clamp with i hook, i hook, lt fuse set., lt pvc cable al 1x120sq.mm., lt pvc cable al 1x400sq.mm., lug sutable for 250 kva
Tender For corrigendum : erection of (i) 2nd circuit stringing (acsr panther conductor) on existing 132 kv dc/sc line from 132/33 kv ss rc puram to 132/33 kv ss patancheru (3.536 km) (ii) 132 kv bay at 132 kv ss patancheru and (iii) 1 no. 132 kv bay at 132 kv ss rc puram in sangareddy district
Tender For tender description : stringing of htls conductor after dismantling of twin aaac moose conductor in existing 400 kv meramundali mendhasal dc line along with up gradation of equipment and bus at respective grid sub station ends
Tender For work of erection of 66kv s/c line on d/c towers from prop. 220kv mandan (mota asarana) s/s to exi. 66kv mota khuntavada s/s with stringing of al-59 conductor (equivalent weight of acsr panther conductor) having approx. length of 10.10 rkm approved under kisan suryodaya yojana phase-ii.
Tender For corrigendum : tender for supply of equipment material design erection testing commissioning for sop to ms shyam indus pvt ltd co prittam singh at vill baghni by prov 1104kv 25kva sstn aw 3ph lt line in vill baghni in e section bhadwar under esd hpsebl nurpur. t - 25 kva trsanformer, prov. distribution transformer (ordinary), 11/0.4 kv, 25 kva ., prov. steel tubular poles (9 m, working load > 200 kgf/m ) ., prov. muffs with concerete filling, prov. x-arm: [channel iron (100x50x6 mm), length : 2800 mm x 2 nos] for incomer line, prov. ms angle iron (50x50x6 mm), length: (2800 mm) x1 nos for las, prov. x-arm: [channel iron (75x40x6 mm), length : (2800 mm x 4 nos] for supporting do fuse unit & go switch, prov. transformer bed, belting & knee bracing, prov. x-arm: [channel iron (100x50x6 mm), length : 2800 mm x 2 nos] for transformer bed, prov. x-arm [channel iron (100x50x6 mm), length : (460 mm) x 2 nos for supporting main channel of transformer], prov. ms angle iron (50x50x6 mm), length : (2800 mm) x 2 nos, prov. ms angle iron (35x35x5 mm), length : (460 ) x 2 nos, prov. ms angle iron (50x50x6 mm), length : (950 mm) x 2 nos for bed knee bracing, prov. transformer lt distribution box and go switch fixing assembly, prov. ms angle iron (50x50x6 mm), length : (2800 mm) x 2 nos, prov. ms angle iron (50x50x6 mm), length : (450 mm) x 1 nos, prov. go switch handle supporting: [channel iron (75x40x6 mm), length : 460 mm, prov. go ab switch unit (11kv, 400a, 25 ka ) tripple pole o/d type, prov. d.o fuse unit, prov. lighting arrester, 9 kv station class (porcelain type), prov. discs insulator sets (comprising 1 no. disc: ^^(porcelain, bs, 12 kv, 90 kn) including dead end clamps etc.), prov. stay set complete, prov. stay wire (7/3.15 mm) (6.0 kg per stay set), prov. pipe earthing set, prov. lt distribution panel box with mccb(160a, 10ka, 4p, 1no) & sfu(32a, 5no, rewirable), prov. half clamp (m.s. flat 50x6 mm), prov. full clamps (m.s. flat 50x6 mm), prov. nuts and bolts of various sizes (galvanised / coated) [preferably 16 mm or more (with flat and spring washers)], prov. aluminium thimble, prov. copper thimble 35 amp, prov. danger plate, prov. barbed wire, prov. lt cable (3.5 core) 50 mm , prov. energy meter 3- , 4 wire ct operated static tri-vector meter with box(ct-100a), prov. aluminum paint., prov. 6/1/3.35, 50mm ., prov. construction of foundation of transformer, erection of 25 kva s/stn. i.e. digging of pit for pole & earthing two no. poles & 3 nos. for earth drilling of holes in x-arms, preparation of plateform str. members c.i., a.l. i.e. x-arms & k.b. set, errection of d/p, concreating of rcc muff errection of plateform, errection of x-arms, d.o., l.a., mccb, switch lt box, energy meter, errection of transformer, earthing connection to g.o. switch, transformer l.a. etc., errection of stay set, jumper, pipe earthing 3 nos set, l.t. cable, barbed wire and painting complete in all respect., transportation charges @10490/-, prov. transportation charges & mannual carriage of 25 kva pole mounted distribution s/stn. (line length 0.500km), erection of 3- ph. lt line, prov. aaac (7/3.15 50mm ) { neutral conductor including 1% (sag, jumpering and wastage}, prov. steel tubular poles (8 m, working load > 200 kgf/m )., prov. muffs with concerete filling, prov. shackle insulator with d-iron, prov. lt stay set i/c egg insulator., prov. nuts and bolts of various sizes (galvanised / coated) [preferably 16 mm or more (with flat and spring washers)], prov. stay wire, prov. g.i wire no 8swg, erection of 8 mtr. st pole single structure i.e. digging of pit, fixing of insulator, x-arms, k.b. set, top clamp, barbed wire, danger plate, drilling of holes and filling of pit + ramming complete in all respect., sagging of conductor i.e. laying, stringing and sagging & binding with insulator (single wire per km)., sagging of g.i i.e. laying, stringing and sagging & binding with insulator (single wire per km)., erection of stay
Tender For erection of 66kv kotda( r)-khirsara line lilo to 66kv (proposed 220kv gadhsisa) ss on d/c panther tower with acsr panther conductor(under anjar construction division) approved under ksy-ii) pkg-2 (ap-22 to ap-42 (stringing up to ap-43))
Tender For erection of 66kv kotda( r)-khirsara line lilo to 66kv (proposed 220kv gadhsisa) ss on d/c panther tower with acsr panther conductor(under anjar construction division) approved under ksy-ii) pkg-1 (ap-1 to ap-21 (stringing up to ap-22))
Tender For erection work of 66kv s/c line from prop. 220kv bagasara (juna vaghaniya) s/s to exi. 66kv bagasara s/s on d/c towers with stringing of al-59 conductor (equivalent weight of acsr panther conductor) up to ap-10/0 m/c tower common point having approx.length of 6.50 rkm (tal.bagasara, dist.amreli).