Tender For bid to ras corrigendum : tender for supply of design and engineering of imcc panel 2 nos and vfds and plc network , design and engineering of apfc and hvac , design and engineering of apfc and field instruments , design and engineering of cables and termination and airconditioning for imcc building , design and engineering of earthing of imcc , field equipments and soil testing , design and engineering of civil buildings and structure foundations , design and engineering of imcc building with earthing system , design and engineering of structural works for cable laying for both incoming and outgoing cables , design and engineering of lighting system of imcc building , equipment locations at ccr ground floor and along the structural path for cable route , design of fire detection and alarm system for building and cable alley area along with integration and display at fire station/existing control centre , supply of imcc panels , vfd panels , supply of apfc panels , hvac system/ air conditioning systems for imcc building and other area air conditioners as mentioned in scope of work , supply of mldb , lighting distribution boards , lighting material including db , light fittings , and all related accessories or wiring material and other electrics etc , supply of field instruments and necessary piping materials as required , supply of plc and other related required accessories , supply of lt cables and other related accessories for electrical , termination material and other instrumentation cables etc and other related electrics as required , supply of cable trays for electrical and instrumentation , supply of all earthing material as per is 3043 for imcc and connection to earth pits for motors , panels etc , supply of fire detection and alarm system for building and cable alley area along with integration and display at fire station/existing control centre , erection , testing , commissioning , and handover of equipments of imcc panels and vfd panels , erection , testing , commissioning , and handover of equipments of apfc panels and hvac system , erection , testing , commissioning , and handover of equipments of lighting system as per above supply , erection , testing , commissioning of earthing system , erection , testing , commissioning of field instruments and necessary piping materials etc as required , erection , testing , commissioning and handover of plc , erection , laying , testing and commissioning of lt cables cable terminations wherever required along with necessary accessories is in the scope of the contractor for electrical and instrumentation , erection , testing and commissioning of cable trays for electrical and instrumentation , erection , testing and commissioning of fire detection and alarm system for building and cable alley area along with integration and display at fire station or existing control centre , substructure excavation , foundation works footings , columns up to plinth level , dpc damp proof course , and backfilling. , superstructure columns , beams , slabs , brickwork or masonry for all floors above plinth level , and formwork up to ground floor , finishes plastering , flooring tiles , marble , painting , wall cladding , and other interior or exterior finishes , plumbing works , fixing of doors up to ground floor. , superstructure columns , beams , slabs , brickwork or masonry for all floors above plinth level , and formwork for subsequent floors as per approved design , finishes plastering , flooring tiles , marble , painting , wall cladding , and other interior or exterior finishes , plumbing works , fixing of doors for subsequent floors as per approved design , supply and erection of structural works for cable laying for both incoming and outgoing cables
Tender For survey, investigation, preparation of design & drawings, installation, testing and commissioning of lift headworks, electrical sub-station, transmission line, terminal bay, rising main, delivery chamber and construction of pipe distribution network including structures and scada compatible sluice valves, butterfly valves, flow meters, discharge control meters and air valves, scour valves, butterfly valves, discharge control meters providing intermediate sump wherever necessary in complete manner etc piped distribution network for 19,600 ha. of command area of pamanakallur and other villages in maski taluk of raichur district from distributary 5a of narayanpura right bank canal including supply of spares, accessories and tools including operation and maintenance of the entire system for five years from the date of successful commissioning of the entire system on turnkey basis.
Tender For the detail of works includes:a. the tenderer shall carryout the following works during annual maintenance contract period along with the servicing of the diesel generator set.1. general checkup & preventive maintenance and to fill up preventive checkup schedule as follows:a) check lube oil level and conditioning of lube oil, top up/refill if required.b) the oil filters shall be replaced whenever oil is changed.c) the air filters shall be cleaned periodically with compressed air, check batteries and top up the distilled water if required.d) check functioning of changing alternator.e) engine safety viz. high water temperature gauge, oil temperature gauge and high speed gauge shall be checked for their functions and repaired/replaced if required.f) coolant level and conditioning of coolant shall be checked and refilled if required.g) check fan and alternator drive belts and tightened if required.h) the governor shall be checked and tuned for proper functioning.i) check for leaks if any and shall be rectified.j) check reports shall be submitted every month/every breakdown calls.2. checking and servicing of engine for smooth running, its unusual sound and color of smoke and exhaust and set it right in case of deviations.3. checking and repairing and leakage of fuel, lubricating oil and coolant.4. cleaning and changing of air filters as per requirement.5. setting of valves tappets whenever required.6. checking and repairing of accessories drive, turbo charger and crankshaft endplay whenever required.7. checking of alignment of engine & alternator as per requirement.8. checking of throttle control and its setting.9. checking of instrument panel including replacement as and when required.10. checking of rotating diodes assembly in brushless alternator including replacement as and when required.11. checking of wiring system and repairing/replacement as and when required.12. repair and maintenance of relays including contractors in control panel.13. checking of battery terminal and de-sulphating.14. diagnosis of faults in engine and alternator and its rectification.15. breakdown calls to be attended on priority within 6 hrs.16. providing spare avrs, self-starter and accessories, free of charge, if the repair/overhaul/replacement is expected to be taken in more than two days.17. checking/repair/adjustment/replacement/servicing shall be carried under annual maintenance contract except cost of component/parts to be replaced due to wear & tear.18. the firm should undertake to arrange genuine spares of the diesel engine, alternator and amf panel as and when required within two working days.19. the tenderer’s service engineer shall visit the site for attending the generator sets not less than twelve times during the contract period (minimum once in a month) and shall inspect the generator set thoroughly. each visit shall take place during 1st week of each month.20. the tenderer’s service engineer shall visit once in two month for checking of electrical side viz. alternator, amf control panel, if any.21. the engine shall be run on no load or at available load, and should be checked for any leakage and abnormal noise. if any such abnormality noticed shall be diagnosed and remedial action shall be taken.22. standard check list:a) replace minor parts (i.e hoses and filters etc) sub-assemblies as and when required.b) service engineers during the visit will report on the performance or any other abnormality and inform parts requirement. he shall also submit the report on work done and recommendations as well as spare parts required.c) attend emergency call on priority (usually same day). however, if the engineer is required or any particular date and time, it would be the responsibility of the customer to intimate the contractor in advance.d) major overhauling/ top overhauling / pt pump & injector calibration /replacement of major parts/ rewinding of alternator or repairs or breakdown of the diesel generator set are to be charge
Tender For bid to ras providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - onboard ins tabar at nd (mbi); electrical system or installation, repair/ refurbishment of boat davit control panels onboard ins tabar; service provider
Tender For chp-ghtp stage-i (2x210mw capacity) & stage-ii (2x250 mw capacity) breakdown, shutdown, preventive & routine maintenance of electrical control, plc system, switchgear, instrumentation system, lighting system etc. including all types of cables etc. installed in chp/awrs & all ht (6.6kv), lt (415v) ac & dc motors with cables in chp, awrs, foph, odph, sump & ahp-i&ii & electrical maintenance of dust extraction, dust suppression and ventilation system of stage i & ii under chp/emc on lump sum basis at ghtp for a period of two years
Tender For corrigendum : ennore sez - establishment of flue gas desulphurisation (fgd) system and its auxiliaries for 2 x 660 mw ennore sez under single epc basis. - engineering, procurement and construction (epc) contract for complete design, engineering, manufacture/procurement, assembly, inspection, testing at manufacturer’s works, packing, forwarding, transporting and insurance, supply of complete machineries (complete mechanical, electrical, instrumentation & control systems and civil, structural & architectural works and mandatory spares at site), assembly, erection, testing, commissioning, trial/ reliability run, conducting performance guarantee tests and handing over of flue gas desulphurisation system and auxiliaries for 2 x 660mw ennore sez supercritical thermal power project at ash dyke of nctps, , tamil nadu.
Tender For corrigendum : engineeringprocurement and construction epccontract for complete design engineering manufacture - tangedco – nctps-ii–(2x600mw) – engineering, procurement and construction (epc) contract for complete design, engineering, manufacture/procurement, assembly, inspection, testing at manufacturer’s works, packing, forwarding, transporting and insurance, supply of complete machineries (complete mechanical, electrical, instrumentation & control systems and civil, structural & architectural works and mandatory spares at site), assembly, erection, testing, commissioning, trial/ reliability run, conducting performance guarantee tests and handing over of flue gas desulphurisation system and auxiliaries for 2x600 mw north chennai thermal power station-ii, chennai-600120, tamil nadu.
Tender For comprehensive annual maintenance contract camc for 6x330 tr central air conditioning plant high side equipment including chiller condenser system cooling tower chilled water pumps condenser water pumps and associated electrical control systems
Tender For construction of centre for ncdc (national centre for disease control) lucknow main block including internal watre supply, sanitary installation, drainage, development works, electrical internal installations, fire alarm and fire fighting system, lifts, substation, dg set, hvac, cctv, street lights, solar generation system, lan, stp and etp, ug and fire sump and miscellaneous works. (sh:- providing services of computer operator for the office of architect, ce (lucknow), cpwd, lucknow).
Tender For quotation for the rate fixation of quotation for the rate fixation of supply, installation, testing, and commissioning of a complete waterfall system for 6.00mtr dia pond as per design, including gi rings for 3-step waterfall formation with ball joint nozzles placed at varying lengths, narrow pool waterfall ss nozzles and plates, and illumination using waterproof led rgb lights with appropriate drivers and cabling. the system shall be operated by a 10 hp submersible horizontal mono block pump set of reputed make, complete with pump strainer, header with water distribution manifold, pressure regulating valves, and all necessary fittings. an outdoor weatherproof electrical panel shall be provided, comprising a starter, ammeter, voltmeter, and other required control and safety components. the entire unit shall be fully operable with the inclusion of any missing accessories, excluding civil works,