Tender For enquiry for procurement of 12v, 180ah heavy duty batteries for diesel generator set control panel, diesel hydrant pump, diesel spray pump, diesel booster and diesel foam pump installed at 500 mw unit, sgtps, mppgcl, birsinghpur.
Tender For bid documents for supply, installation, testing and commissioning of silent type diesel generator sets of various capacities including control panel, fuel system, exhaust system, battery backup, and alied electrical and civil works at fire station & municipal corporation building of nadiad municipal corporation, nadiad.
Tender For maintenance and operation of subways, storm water pumps, fobs and related electrical installation, lt panel board, diesel generator set and dewatering pumps under pwd south east, new delhi.
Tender For hired 82.5 kva, 415v, 66 kw diesel generator set in sae (semi acoustic enclosure) with automatic changover panel at kala bhavana, nandan building
Tender For tender for supply of m and l for searching fault location of ht ug cable 11000 volts laid in trenches ducts with the help of electronic fault locating machine comprising of surge generator pulse echo fault locator with frequency distance calculator etc incl transportation of machinery excavation in normal soil strata exposing the cable fault removal of deteriorated portion of the cable treating of cable of any size including disconnecting and re fixing cables with lugs as per direction of engineer in charge note a charges of cable fault locator and dg set including transportation charges deemed to be included in the quoted rate b necessary testing of cable after making joint will be deemed to be including in the cost of relevent item , supply jointing and testing indoor type cold shrinkable end termination cable joint including all material and accessories suitable for 3 core x 120 minus 185 sqmm xlpe cable of 11000 volts e grade complete all as specified and directed note cost of cutting of existing end termination joint deemed to be included in unit rate , m and l for cable jointing kit for 11 kv earthed grade cable for straight through cold shrink type complete with joining material and accessory suitable for 120 to 185 sqmm 3 core xlpe armored aluminum conductor cable complete all as specified and directed , supplying and laying in repair xlpe insulated screened pvc bedded galvanized steel strip or wire armoured , electrical power cable heavy duty with aluminum conductor 11000 volts grade cross sectional area 120 sqmm x 3 core complete all as specified and directed , supply and fixing in repair mccb 400 amps 3 pole 415 volt 36 ka including under voltage over voltage relay with adjutable thermal setting 80% minuse 100% all as specified and directed , m and l for complete repairing serviceing of ht 11 kv vaccum circuit breaker vcb after disconnecting of all incoming and outgoing connection checking finding of the defective spare parts removing of all moisture content with suitable grade chemical replacement of rusted nuts bolts and washer replacement of all unserviceable post insulator and repair of all busbar joints and covered with ht insulation tape complete external surface as per existing colour and quality replacemnt of all defective internal ac dc circuit wiring repair servicing of breaker trolly including motorized operating mechanism ct pt power pack and calibration of triping relays system and tripping mechanism for regulating the fault flow over current earth fault differential in sequence from down streem to receiving sub stn for accuracy and effective functioning of vcb complete all as specified and as directed note nuts bolts washer cleaning material insulation tape copper wire for circuit wiring and defective ht 11 kv 2 amp fuse carrier oiling greasing to charging spring replacement of hrc fuse 110 220 volt 5 amps setting of over current earth fault relays complete other minor items for repair of breaker shall be deemed in qouated rate replacement of major unserviceable spares accessories shall be measured and paid separately under relevant items , supply and fixing heater 230 volts ac 60 watt for 11 kv ht vcb panel complete all as specifed and as directed make heatco vileco electrical , supply and fixing in replecement of spring charging gear for 11kv vcb panel suitable for 630 400 amp complete all as specified and directed , supply and fixing vacuum interputer for ht11 kv vcbs 630 400 amps brakding capacity 13point 1 ka suitable for alstom make vcb complete all as specified and as directed , taking down and repairing overhauling of air break gang operated switch with do fuse unit 200 amp 400 amp capacity triple pole mechanically operated mounted on insulators and steel frame installed vertically horizontally replacement of broken worn out components oiling and greasing of mechanical moving parts smoothing and polishing of electric contacts with providing conducting jelly of contacts refixed the same after re
Tender For providing of custom bid for services - 200150426 expert jobs of switchyard control and protection main plant ht and lt switchgear and generator relay panel stage i and ii
Tender For providing annual comprehensive maintenance of 33 kv sub station ht side and lt side, 2 x 2000 kva transformer, 2 x 1250 kva diesel generator set with all panel and allied accessories at atal bihari vajpayee government medical college and hospital vidisha dist vid