Web Analytics Made Easy - StatCounter

Amino Acid Analyzer Tenders

Get complete information related to latest Amino Acid Analyzer Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Amino Acid Analyzer Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Amino Acid Analyzer Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :39103583 Due date: 13 Feb, 202513 Feb, 2025 21.25 Lacs
Tender For purchase of lab equipments for division of soil and water engineering, faculty of agril. engineering, chatha - soil & water engineering lab equipments:-, rainfall-simulator specifications: closed water circuit unit surface are: 2x1 m2 tilting: variable adjusted range with screw jack tilting system nozzles at variable heights field test setup with variable slope equipped with flow meter complete lab setup with pump sump tank and permeable media, darcy law apparatus specifications:- test section: material stainless steel water circulation: 0.5 hp pump standard make flow measurement: using measuring tank (capacity 25 litres) sump tank: capacity 50 litres stopwatch: electronic pressure measurement: differential pressure manometer control panel complete lab set up, demonstration infiltration apparatus specifications:- three graduated cylinders resting on permeable support screen complete apparatus supported by metal stand user instruction manual, sediment transport demonstration apparatus specifications:- inclined channel with acrylic sheet channel mounted on ms frame pump along with sump tank complete demonstration unit, digital water analysis kit specifications:- ph range: 0 to 14 ph temperature: 0-100 c resolution: 0.01ph accuracy: 0.01ph 1 digit conductivity: range: 0-20 ms resolution: 0.1 mhos accuracy: 05% fs 1 digit tds range: 0-20 ppt essential accessories, time domain reflectometer (digital soil moisture, temperature & conductivity meter specifications:- 3 element 10 cm stainless steel waveguide 34 mm round cross section with glue on protrusion for matching 1 schedule 40 pvc pipe 5 m 3-conductor water proof cable waterproof epoxy filled housing rechargeable lithium battery with power adopter display data on the lcd screen volumetric water content: 0% to 100% electrical conductivity range : 0 to 5000 s/cm working temperature: 0-50 0c accuracy : 2 % other essential accessories, frequency domain reflectometer (digital soil moisture meter) specifications:- soil moisture range: 0 to 100% probe depth measurements: 70-80 cm measurement method: fdr working temperature: 0-40 0c accuracy : 2% resolution: 1% digital datalogger digital display other essential accessories, depth integrating suspended sediment sampler specifications:- used in shallow streams used with wading rod suspension, tensiometer (digital soil tensiometer system) specifications:- tensiometer tubes: sizes like 15, 30, 45, 60 & 75cms electronic gauge for reading moisture tension in lcd display measuring range : 0-100 kpa portable & battery operated screw type soil auger 1 m long with t handle accessories: stoppers, needles & tags etc., coshocton wheel (30 cm) specifications:- material: mild steel (m.s) thickness: 2 to 6 mm diameter 40-80 cm no. of vanes :6-8, h flume (30 cm) specifications:- shape : v shape size: 30cm features of both flumes and weirs cast iron or mild steel bottom flat, submersible pump, cut sectional model specifications:- 1 hp, 25 mm x 25 mm stage : single stage motor phase: single material: cast iron the equipment consist of real life pump sectioned to expose the internal working parts pump should be mounted on ms frame the equipment consist of real life pump sectioned to expose the internal working parts, reciprocating pump, cut sectional model specifications:- plunger type single cylinder size of the pump: 1.5 x 1 motor : 0.5 to 1 hp pump should be mounted on ms frame the equipment consist of real life pump sectioned to expose the internal working parts, centrifugal pump, cut sectional model specifications:- 5 hp single stage material: cast iron gland seal pump should be mounted on ms frame the equipment consist of real life pump sectioned to expose the internal working parts, model for drop inlet spillway specifications:- cast iron/ms steel complete demonstration unit, model for chute spillway specifications:- cast iron/ms steel complete demonstration unit

corporations/Associations/Others

CTN :39103649 Due date: 17 Feb, 202517 Feb, 2025 NA
Tender For supplyand installation ofscience lab equipment to govt womens college sundargarh - science lab equipments (zoology), dissolve oxygen meter-micro controller, magentic stirrer, student microscope - economy model, pcr -96 weelcomplete with all acessories, vortex mixer, refrigerator, beaker, digital blood pressure monitor, premanent slides of all tissue, sphygmmano meter, skeletons of bird, skeletons of mammal, permnent slides of t.s. oesophagus, stomach, intestine, ovary, testics, thymus, sleen, liver, molecurlar biologysmart pcr 7 inch lcd - automatic, science lab equipments (botany), sohxlet apparatus, digital spectorphotometer with pc, vacuum dessicator and dessicator cabinet, hplc with pda detector, electronics balance, double door refrigerator, herbarium cabinet, herbarius press, gas chomatography, plant photosynthesis meter, microcentrigue, rotary evaporator, micropipettee set, autoclave, pcr -96 weelcomplete with all acessories, tripod stand, glassware set, was bottle, hot air oven, electronics balance, deep frezer, millipore water system, ultrasonic bath, plastic wares, science lab equipments (physics), quantum mechanics, spliting of dpph using esr technique, zeeman effect with(triplet & doublet) 1 mp camera, solid state physics, to mesure the magnetic susceptibility of solids, element of modern physis, to setup the millikan oil drop apparatus and determine the charge of elecron (with pc connectivity facility), wave & optics, meldes experiment with 3 a power supply, thermal physics, to determine the temperature coefficient of resistance by platinum registance thermometer, electricity& magnetism, slef inductance of a coil by andersons bridge with null detector, constant deviation spectorgraph, science lab equipments (chemistry), gas chomatography, conductivity meter, hplc with pda detector, polarimeter, kjeldahl apparatus, water and soil analysis, oxgen meter with dissolve oxygen probe - digital do meter, cod meter, bod incubator, suction pump, karl fisher titrator, double distlled water assembly, digital muffle furnace, furnace, high volume air sampler, rotary evaporator, deep freezer, digital tds meter

Central Government/Public Sector

CTN :39104702 Due date: 01 Feb, 202501 Feb, 2025 NA
Tender For rectification of engineering defects as per rfp - defect rectification of various engineering defects as per rfp, e-647:leakage observed frequently from port gearbox lub oil cooler sea water outlet line due to deterioration. same to be renewed as per sample. (mat-cuni, l-1.5 mtr, dia-80 mm). inway job includes removal of defective line and fitment of new pipeline., e-655: abnormal vibration observed from fwd bilge & ballast pump view 02 in nos. foundation frame angles deteriorated. defective frame angles of foundation to be renewed as per sample and proved for satisfactory operation (mat:-ms, size-150x1.2x0.7 cm). in way jobs includes:- (i) removal of suction and discharge pipeline.(ii) removal of motor and pump from foundation.(iii) cutting of defective frame angles.(iv) welding of new foundation frame angles. (v) fitment of pump with motor and system lines post renewal of foundation frame angles.(vi) carrying out vibration analysis of pump., e-656: leakage and abnormal vibration observed from sea water motor driven pump of stbd gearbox. suspect mechanical seal and bearing worn out. defect to be rectified and pump to be proved for satisfactory operation. in way job includes:-(i) removal of suction and discharge pipeline.(ii) removal of pump from foundation.(iii) replacement of mechanical seal and bearings.(iv) fitment of pump and system lines post repair., e-657: the following equipment system valves are not holding due to defective valve spindle/seat. valves spindles to be renewed as per sample. valves to be overhauled and pressure tested up to test pressure. in way job includes removal and fitment of valves with associated system post repair. (mat:-brass).ser equipment size qty(a) da no. 2 & 4 sdnr (65 nb) 02 nos.(b) ro plant sdsl (25 nb) 01 no.(c) calorifier sdsl (40 nb) 01 no.

State Government

CTN :39123203 Due date: 02 Feb, 202502 Feb, 2025 10.00 Lacs
Tender For appointment of agency for conducting a comprehensive census survey focus on data collection and analysis on sewerage system water supply and waste disposal practices across sectors for sustainable development and policy formulation in municipal limit

corporations/Associations/Others

CTN :38813348 Due date: 03 Feb, 202503 Feb, 2025 NA
Tender For corrigendum : providing of repair and overhauling service - technical support services for steam water analysis system analysersat nntps 2x500mw power plant for both units. (each visit will be for 08 man days):

CTN :38940732 Due date: 03 Feb, 202503 Feb, 2025 58.00 Lacs
Tender For purchase of various apparatus/instruments required for department of chemistry, chaudhary ranbir singh university, jind - rota-evaporator the rota-vapour should have a vertical condenser for standard applications with cooling surface area of 1500 cm2 or better with a protection class of ip20 or better. the rotation speed of the instrument should be 20-280 rpm or better. the water bath should have controlled temperature range of heating within a range of 0-90oc or better with a capacity to accommodate evaporating flask from 50-4000 ml with same joint. all glass components should be made of borosilicate 3.3 glass. digital interface of 4 inches or better to facilitate monitoring of temperature, speed and vaccum. there should be a provision of power cut off when actual temperature exceeds set temperature or by rapid temperature increase. the system should have timer function to regulate the time of the process and automatic aeration when pressure reaches above 1400 mbar. the entire system should have ce/csa approvals. the vaccum pump should be made up of chemically resistant ptfe diaphragm vacuum pump with a suction capacity of 1.5m3/h or better with 2(2) number of steps(heads). the final vaccum should be 7-10 mbar. the recirculating chiller should be of 3l capacity with a working temperature range of room temperature to -10oc and a cooling capacity of 500 w at 15oc., ft-irthe ftir instrument should have transmission interface which provides classic infrared sampling for the measurement of solids, liquids or gases. the transmission module is purgeable and preferable to come with a standard cardholder. the scan range should be from 8000-350 cm-1 with a spectral resolution of 0.5cm-1 or better. the signal to noise ratio: 35000:1 or better. the system should have michelson type/ rock solid/self-compensating, dynamically aligned interferometer which removes any tilt and shear scanning error with 10 years warranty on interferometer. the system should have temperature stabilized or dtgs detector/ temperature control dlatgs detector. kbr/ znse beam splitter to meet complete spectral range. the system should be operable through a windows 10 compatible software with self-diagnostic after initialization, provision for creation of library. the software should have spectral, peak and text search function. the software should be capable of comparing spectrum, quantification and photometric data. there should be a provision of digital humidity level monitoring in internal optics through software and customized template. the system should be supplied with following accessories.hydraulic press for kbr pellet preparation software recognize diamond atr accessory with force monitoring for quick analysis of different sample) solid, liquid, paste and gels) of food, raw material, packaging material etc.installation, familiarization at installationpccorei5, 4gb ram, 1 tb hdd, 18.5 led/lcd, windows 10 , uv visible spectrometer microprocessor based wavelength range: 190 to 1100 nm with 7-8 inch led display. the system must have pre-programmed methods for water parameters which should be compatible with available reagents for the water testing. system should be true double beam uv-visible spectrophotometer with 8-cell changer the monochromator should be blazed czerny-turner type with 1200 lines/nm blazed grating. the detector should have si-diodes/ccd. system should have wavelength range from 190 to 1100 nm or better system spectral bandwidth should be 1 nm (190 to 1100 nm) wavelength setting should be 0.05 nm wavelength accuracy should be 0.3 nm wavelength repeatability should be 0.1 nm or better scan speed max 6,000 nm/min or better photometric range absorbance : -4 to 4 abs transmittance range should be : 0 % to 400 % photometric accuracy should be less than 0.005 abs at 1.0 abs light source tungsten halogen lamp & deuterium lamp photometric repeatability 0.0002 at 0.5 abs baseline stability: 0.0003 abs/h operating system (os): system should have to

Central Government And Public Sector

CTN :38779226 Due date: 01 Feb, 202501 Feb, 2025 NA
Tender For corrigendum : supply of amino acid analyzer

State Government

CTN :38984924 Due date: 27 Jan, 202527 Jan, 2025 10.00 Lacs
Tender For appointment of agency for conducting a comprehensive census survey focus on data collection and analysis on sewerage system water supply and waste disposal practices across sectors for sustainable development and policy formulation in municipal lim

State Government

CTN :38945491 Due date: 13 Feb, 202513 Feb, 2025 NA
Tender For regular upkeep for on-site mobile analysis system omas installed in various water testing laboratories of phe dte., govt. of west bengal

CTN :38917495 Due date: 01 Feb, 202501 Feb, 2025 12.00 Lacs
Tender For purchase of various apparatus/instruments required for department of chemistry, chaudhary ranbir singh university, jind - stirrer the stirrer should be made up of ceramic coated aluminium alloy top with digital speed and temperature control. the stirring speed should be 50-1500 rpm or better. the stirrer should be operational up to a temperature range of 300oc with an accuracy of 1.0oc and ip 42 protection class. the input power should be 600 w or above. the stirrer should be supplied with hemispheric bowl (100 ml= 1 no; 250 ml= 1 no) to replace oil baths and mantles in order to perform clean and safe analysis with round bottom flasks., electronic balance the electronic balance should have a maximum weighing capacity of 200 g or more with a resolution and repeatability of 0.1 mg, and a response time of 5 sec or better. the system should have automatic internal calibration with touch screen display. the system should have internal database capacity of 2500 or more with multiuser password protection feature. , vacuum pumpthe pump should be operational at a maximum power of 65 w or more with a max. vaccum of 99 mbar or more. the pump should be fitted with vacuum and filter cartridge., hot air oventhe inner chamber should be made of stainless steel and the outer chamber should be m.s powder coated. the maximum capacity of the oven should be 100 ml or more. the operational temperature should be between ambient to 250 oc or more with a temperature accuracy of 1o c. pid based digital temperature control., double distillation unitthe unit should be pyrogen free with a distillation water output capacity of 1.5 l/h. the minimum cooling water requirement should be 1lt/min. auto-power cut facility in case of halted supply of water., circulating oil baththe oil bath should be made up of stainless steel with 4 digit 7 segment led display for temperature and time. the bath should have s.s perforated tray for holding flasks. the bath should have a capacity to accommodate flask of 1l. the working temperature range should be +5 to 240 oc (0.1 oc increment) with a temperature stability of 1oc., water baththe water bath should have a capacity of 20 l within built water level sensor. the bath should be made up of stainless steel and supplied with 8 concentric rings. the bath should have digital temperature control with pt100 sensor. the system should have stirring capability with ptfe magnetic bars. , ph conductivity meter operational between a ph range of -2 to 16.00 with a resolution of 0.01 ph and an accuracy of 0.02 ph. 5 points calibration. the ec range should be in between 0.00 to 29.99 s/cm, uv cabinet operational at two uv wavelengths (254 and 365 nm). the cabinet should also be equipped with one visible light. the external body should be coated with ms powder/epoxy., flame photometerapplication: the flame photometer is used for qualitative and quantitative determination of several cations, especially for metals that are easily excited to higher energy levels at flametemperature. these metals include na+, k+, ca2+, ba2+ and li2+.specification requirementmeasuring range na+: 0 to 99.9 ppm k+:0 to 99.9 ppm ca2+ :0-99.9 ppmli2+: 0 to 99.99 ppmsensitivity na+= 0.1 ppmk+ = 0.1 ppmspecificity less than 0.5% interference when concentrations are equal to test sample concentrationsgas control-adjustable with knobsignition system-auto ignition systemflame failure-auto detectiongas cut off-automaticreproducibility-less than 1% coefficient of variation for 20 consecutive samplesusing 10 ppm na set as maximum standardlinearity-less than 1%display led, 12.5 mm (1/2")fuel supply-high-grade propane/butane mixture regulated at approximately30 psiair supply-6 l/min at 12 psi; oil and moisture freerecorder-output 0.05 to 5 v (switchable)operating manuals, service manuals, other manuals should provide user, technical and maintenance manuals in english language list of equipment and procedures required for local calibration and routine maintenance service and
 Loading, Please wait...

Connect us via What's Up