Web Analytics Made Easy - StatCounter

Ammonia Compressor Spares Tenders

Get complete information related to latest Ammonia Compressor Spares Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ammonia Compressor Spares Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ammonia Compressor Spares Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :38212033 Due date: 09 Dec, 202409 Dec, 2024 1.26 Lacs
Tender For supply of electrical and machinery spares - thermostatic expansion valve , mcb 2 amps , mcb 16 amps , mcb 4 amps , relay , under voltage coil for msb breaker , compressor suction pressure switch , filter dryer complete , refrigerant suction pressure gauge , refrigerant discharge pressure gauge , crank case heater , cathode protector or zinc anode , belt for fan , air filter , compressor discharge pressure switch , cylindrical fuse , shore supply breaker , window wiper blade

Central Government/Public Sector

CTN :38212140 Due date: 25 Nov, 202425 Nov, 2024 7.14 Lacs
Tender For providing of repair and overhauling service - : control cabin ac compressor lp trip observed frequently and refrigerant leakageobserved from control cabin ac system hp and lp hoses. suspect minor cracks/ pinholes onrubber hoses of ac system. following jobs to be undertaken and ac system to be provedfor satisfactory operation

Central Government/Public Sector

CTN :38228724 Due date: 06 Dec, 202406 Dec, 2024 NA
Tender For tmpl/pur/rc/kc-09 ammonia compressor spares/216/322

CTN :38067845 Due date: 18 Nov, 202418 Nov, 2024 NA
Tender For procurement of refrigerant gas r-22 mafron gasand compressor gas r410a for the year 2024-25

corporations/Associations/Others

CTN :38171558 Due date: 09 Dec, 202409 Dec, 2024 NA
Tender For supply of refrigerant air dryer compressor

Central Government/Public Sector

CTN :38192848 Due date: 26 Nov, 202426 Nov, 2024 NA
Tender For supply of isi marked self contained drinking water cooler with (non-cfc refrigerant) energy efficient compressor cooling capacity 150lph type, storage capacity 150l, rate of max. energy consumption/rati ng: 1550 watt, 230v, 50hz conforming to is 1475(part 1):2001 latest make-usha, sidwal, voltas, bluestar o r similar [ warranty period: 30 months after the date of delivery ]

Central Government/Public Sector

CTN :38163391 Due date: 20 Nov, 202420 Nov, 2024 32.84 Lacs
Tender For provision of air conditioners water coolers and misc items at kushinagar international airport - supply , installation , testing & commissioning of 5 star , 1.5 tr high wall type split inverter air conditioner unit with rotary compressor operating on refrigerant r-32/non cfc & copper condensor coil of outdoor unit & having cordless lcd remote , auto restart operation with copper refrigerant gas pipeline insulated with nitrile/polythene foam i/c electrical cable of suitable size copper conductor from indoor to outdoor unit (both upto 10 feet ) i/c standard drain pipe , ms base frame / platform duly epoxy painted for outdoor units suitable for operation on 230v , 50 hz single phase ac supply and capable of performing such standard function like cooling , dehumidifying , air circulating etc complete as required. , supply and fixing of extra copper refrigerant piping (beyond the standard length) complete with suction/ liquid line along with insulation and electrical cabling with pvc protection piping for cable and all accessories required for 1.5 tr as per site requirement. , supply , installation , testing & commissioning of 5 star , 2 tr high wall type split inverter air conditioner unit with rotary compressor operating on refrigerant r-32/non cfc & copper condensor coil of outdoor unit & having cordless lcd remote , auto restart operation with copper refrigerant gas pipeline insulated with nitrile/polythene foam i/c electrical cable of suitable size copper conductor from indoor to outdoor unit (both upto 10 feet ) i/c standard drain pipe , ms base frame / platform duly epoxy painted for outdoor units suitable for operation on 230v , 50 hz single phase ac supply and capable of performing such standard function like cooling , dehumidifying , air circulating etc complete as required. , supply and fixing of extra copper refrigerant piping (beyond the standard length) complete with suction/ liquid line along with insulation and electrical cabling with pvc protection piping for cable and all accessories required for 2 tr as per site requirement. , supply and fixing of 20 mm. dia. u-pvc plumbing/drain pipes required for 1.5 tr split acs on surface including all accessories like bends , sockets and water seal joints etc. complete as required. , supply and fixing of 4 kva automatic digital voltage stablizer having working range 170-270v and complete with connections , testing and commissioning etc. as suitable for 1.5 ton split type air conditioner as per aai preferred make list. , supplying and fixing 20 a , 240 v , spn industrial type socket outlet , with 2 pole and earth , modular type plug top alongwith 20 a c curve , sp , mcb , in pvc box/enclosure , on surface or in recess complete with connections , testing and commissioning etc. as required. make havells , model dboxx mcb protected pvc plastic base model (white) , asin b07bvkq17h or equivqlent. , wiring for circuit/ submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor , single core cable in surface/ recessed steel conduit as required. 2 x 4 sq. mm + 1 x 4 sq. mm earth wire , supply , installation , testing and commissioning of 4.0 tr air-cooled tower/ standing type ac alongwith vibration isolator , as per latest bee standard fitted with 100 percentage copper condensing unit comprising of sealed rotary type compressor with inverter technology and non cfc refrigerant like r410a suitable for stabilizer free operation at 3ph , 415v , 50hz ac supply as required , including supply of power cable , copper piping upto 3 meter and drain pipe upto 3 metre both copper pipe and drain pipe separately enclosed in with nitrile ruber insulation including wrapping in white vinyl tape power cabling between indoor and outdoor upto 3 metre , all necessary ms structure for supporting units , anchor fasteners , nut , bolts , with outdoor stand and ms stand painted with anti-rust paint for mounting outdoor units etc. complete as re

CTN :38170255 Due date: 28 Nov, 202428 Nov, 2024 80.00 Lacs
Tender For annual opeartion and maintenance technical service contract for refrigeration system consisting of compressor condensor refrigerant pump evaporator ice bank tanks for madurai dairy for two years

CTN :38127165 Due date: 28 Nov, 202428 Nov, 2024 5.97 Lacs
Tender For supply of laboratyr and scientific instruments/tools - laboratory and scientific instruments/tools, compressor: type: refrigeration compressor, hermetically sealed, reciprocating, refrigerant type: r22, cooling capacity: 2355 kcal/hr type, voltage 220-240 v ac, 1- phase (details as per sl. no. 1 at annexure-i)., compressor: type: refrigeration compressor, hermetically sealed, reciprocating, refrigerant type: r134a, cooling capacity: 1411kcal/hr, voltage: 440vac, 25mfd, 1- phase (details as per sl. no. 1 at annexure-i)., compressor: type: refrigeration compressor, hermetically sealed, reciprocating, refrigerant type:r134a, cooling capacity: 0.25hp; supply voltage: 220-240 v ac, 1- phase (details as per sl. no. 1 at annexure-i)., capillary tube : 1.12 mm od, material: copper astm b280 (details as per sl. no. 2 at annexure-i)., capillary tube : 1.20 mm od, 8 ft, material: copper astm b280 (details as per sl. no. 2 at annexure-i)., capillary tube : 1.40 mm od, material: copper astm b280 (details as per sl. no. 2 at annexure-i)., capillary tube : 0.95 mm od, material: copper astm b280 (details as per sl. no. 2 at annexure-i)., thermostatic expansion valve: orifice- 0 no., connection-1/2 x 3/8 flare (details as per sl. no. 3 at annexure-i)., thermostatic expansion valve: ten 068z3348, q-33311 r134a -40 to 10 ps 34 bar. (details as per sl. no. 3 at annexure-i)., hand stop /manual shut-off valve: media: r22, r502, r134a, r407c, r410a; port size: 3/8" sae; cooling method: direct cooling; power: manual; including brass material nut bolt. (details as per sl. no. 4 at annexure-i)., hand stop /manual shut-off valve: media: media: r22, r502, r134a, r407c, r410a; port size: 1/4" sae; cooling method: direct cooling; power: manual; including brass material nut bolt. (details as per sl. no. 4 at annexure-i)., evaporator coil : 1/4" od, material: copper astm b280 (details as per sl. no. 5 at annexure-i)., condenser coil ; 3/8" od, material: copper astm b280 (details as per sl. no. 6 at annexure-i)., dimmer stat : 1500 w, 230 v ac. single phase, 50hz (details as per sl. no. 7 at annexure-i)., pressure gauge : connection 1/ npt 8 0 - 200 psi dial size 2.5" (63mm), connection sizes 1/4" (details as per sl. no. 8 at annexure-i)., digital temperature indicator : range -30 to 200 0c, power supply 230vac, digital display, accuracy 0.01 c channel -12 (details as per sl. no. 9 at annexure-i)., digital temperature indicator : type input cr-al(k-type), rang- 0 0c to 200 0c supply- 230vac, 50hz, channel -12 (details as per sl. no. 9 at annexure-i)., ammeter (digital) : rang 0-10 amp. single phase, digital display, 230v,10%vac (details as per sl. no. 10 at annexure-i)., voltmeter (digital) : rang 0 300-volt, single phase, digital display (details as per sl. no. 11 at annexure-i)., hp/lp cut out relay : hp- 8 to 32 bar, lp-0.2 to 7.5 bar, dual controls, 240 v, 50 va, single pole changeover switch (spdt), contact load 240 v ac: 8 fla, 48 lra (details as per sl. no. 12 at annexure-i)., energy meter : a.c. single phase, 2 wire solid state (static) fully electronic energy meter, accuracy class 1.0 & current rating 5-30 amp. with backlit lcd display for240 volt system fitted with pilfer proof meter box.(details as per sl. no. 13 at annexure-i)., r-134a refrigerant gas : 5 kg filled cylinder; moisture less than 0.001; purity: 99.9%; appearance: colourless; application: refrigerant; type of refrigerant-r134a. (details as per sl. no. 14 at annexure-i)., r-141b refrigerant gas : 5 kg filled cylinder; purity 99.9% appearance: colourless (details as per sl. no. 15 at annexure-a)., r502 refrigerant gas : 5 kg filled cylinder; acidity 0.00001 % appearance: colourless purity 99.9 % (details as per sl. no. 16 at annexure-i)., r407c refrigerant gas : 5 kg filled cylinder; appearance: colourless purity 99.9 % (details as per sl. no. 17 at annexure-i)., r-1234ze hfo refrigerant gas : 5 kg filled cylinder; moisture less than 0.001; purity: 99.9%; appearance: colourless; (de

Central Government/Public Sector

CTN :37241997 Due date: 13 Nov, 202413 Nov, 2024 62.21 Lacs
Tender For bid to ras corrigendum : supply of ac spares for hemm air filter 125ac92594 , blower assembly 24v 2658683891 , compressor 955ac02151 , filter air 17 5x5 5x0 34mm 955ac11531 , receiver drier 955ac11953 , thermostate 955ac81484 and rd442724 , binary pressure switch 955ac81573 , refrigerant gas r134a , condenser r6260 , evaporator core assembly rd21370op , radiator condenser rd43945op , receiver drier rd511188op , ac crimping tool rd51125op , blower motor assly rd5129331p , 3 speed switch rd53646o , hose 6 rd55006000p , motor 24v rd5504924 , motor 24v rd5512024p , control knob rd559280 , relay 24v rd56693op , high pressure switch rd568330p , 8 female 90 degree rd56840op , expansion valve rd56868op , 6 female 90 degree rd56945op , 10 male straight rd56951op , expansion valve rd570150p , compressor oil rd57103op , fitting rd57225op , 10 female 90 degree rd57231op , receiver drier rd57272op , 6 male straight rd57805op , fan motor assy 24v rd586276p , fan motor assembly rd590763p , remote mounted condenser r9730 , pressure switch rd59577op , fan motor assy 125ac94465
 Loading, Please wait...