Get complete information related to latest Anesthesia Pump Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Anesthesia Pump Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Anesthesia Pump Tenders.
Tender For repair/replacement of lt ug cable, lt poles, control panels board, change over switches and allied items at af station naliya under ge(af) naliya - taking out old unserviceable lt cable of any size any type from trench/duct/ poles / roof/pipe etc and keeping aside for segregation of serviceability. serviceable cable will be re-laid at same place or other place as required complete all as specified and directed., supply, laying and connecting xlpe insulated, armoured, heavy duty electric cable multi stranded aluminum conductors, 1100v grade, of size 06 sqmm 2core with proper size of lugs and laid in trenches / ducts / through gi pipe / fixed to poles etc complete all as specified and directed. note: excavation earthwork, cable covers, sand cushioning and gi protection pipe shall be measured and paid separately under relevant item., all as per serial item number 2.00 here-in-before but of size 16 sqmm 4 core., all as per serial item number 2.00 here-in-before but of size 35 sqmm 3.5 core, all as per serial item number 2.00 here-in-before but of size 50 sqmm 3.5 core, all as per serial item number 2.00 here-in-before but of size 70 sqmm 3.5 core, all as per serial item number 2.00 here-in-before but of size 95 sqmm 3.5 core, re-laying of old serviceable cable of any size obtained from item above. note:- excavation earthwork, cable covers, sand cushioning and gi protection pipe shall be measured and paid separately under relevant item., excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth and getting out in soft/ loose soil, for laying of under ground electric cable, pipes etc complete all as specified and directed. note:-(i) authorised width & depth shall only be excavated, measured and paid as specified in clause 3.2.3 of ssr part ii and 19.74.1 of ssr part i for cable/pipe laying portion.(ii) serviceable pcc /rcc cable cover obtained during excavation shall be stacked separately carefully without any extra cost to the deptt., material and labour for river bed sand filling in trenches/ ducts 15 cm above cable and 8 cm under the cable for cushioning/protection to cable including spreading, leveling and get thick 18cm after hand punning complete all as specified and directed, laying only serviceable un-reinforced precast concrete cable cover class lv, type 1, flat, of 250 mm x 150 mm x 40 mm obtained from trenches, abetting each other with gap between adjacent slab not exceeding 10 mm over under cable for protection complete all as specified and as directed., supply and laying un-reinforced precast concrete cable cover, class lv, type 1, flat, size 250 mm x 150 mm x 40 mm abetting each other with gap between adjacent slab not exceeding 10mm over under cable for protection complete all as specified and as directed., returning, filling in, including spreading, leveling, watering and well ramming in layer not exceeding 25cm thick each complete all as specified and directed., removing excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.50 metre above the starting point complete all as specified and directed., material and labour for cutting under the road /pavement /hard standing or in any other situation with the manual labour for crossing of u/g cable through it and making both the end good complete all as specified and directed ., supply and laying gi water tubing of 80 mm bore, light grade, is-1239 marked with all fittings is marked and laid in trenches/under roads/in drains with suitable size flat iron/gi clamps, bolts, nuts and washers etc for cable protection complete all as specified and directed., supply and laying gi water tubing of 50 mm bore, light grade, is-1239 marked with all fittings is marked and laid in trenches under roads/in drains, fixed to poles/walls with suitable size flat iron/gi clamps, bolts, nuts and washers etc for cable protection, complete all as specified and directed ., supply and laying gi water tubing of
Tender For survey, investigation, design, supply, installation, testing and commissioning of lift irrigation system (head works consisting of construction of intake well with connecting pipe, jack well cum pump house, vertical turbine pumps coupled to motors, pump house electrical works, necessary valves, delivery pipe, manifold system electrical panel, soft starter, capacitors, 11 kv power transformer, 11/0.433 kv sub-station, 11 kv power line and 11 kv terminal bay, rising main, pressure distribution, gravity distribution, stand pipe) for filling up of 6 nos mi / zp tanks by lifting water from krishna river near ganeshwadi village of kagwad taluk including operation and maintenance for a period of 5 years after successful completion of work for kagwad tank filling scheme- stage-ii on turn-key basis
Tender For provision of power supply infra items for implementation of leh-chushul-thakung itbp link in ba leh. (rate contract for 06 sites) - sub head-i:- (dg set), supply of diesel engine alternator set suitable to generate 5 kva at site conditions, cpcb-iv, totally enclosed diesel engine of suitable to deliver minimum 8.0 bhp (at ntp) , factory assembled and factory tested single/multi cylinder air / water cooled electric start ready to use (rtu) type, housed in a sound proof canopy with manual control panel and coupled with 5 kva single phase, 230 volts alternator at 1500 / 3000 rpm, 0.8 lagging power factor, h-class insulated winding, mounted on rigid ms sheet channel base-frame of sturdy design with necessary reinforcement and with in-built fuel tank of sheet metal, suitable enough for minimum 8 hours running of dg, complete with drain valve, air vent, inlet, outlet connections and gauge. complete with all accessories, battery, engine control panel and having lube oil pressure meter, fuel level gauge, voltmeter, ammeter, frequency meter, engine rpm meter complete as per specifications attached., supplying , installation, testing and commissioning of maintenance free chemical earth station as per latest rdso specifications consisting of :-a) copper bonded steel electrode of 3 meter long, 17 mm dia with copper bonded thickness of minimum 250 microns and ul listed and marked - 1no.b) maintenance free, environmental friendly, mineral compounds, semi soluble , non corrosive , conductivity improving material of rdso approved- 35 kgc) polyplastic , heavy duty, weatherproof, environmetle free earth pit chamber with cover size approx. top dia 250mm, bottom dia 330 mm and height 260 mm heavy duty of 7 ton load capacity, the base unit should have knockouts for interconnecting of strips- 1no., providing and fixing 32 mm x 3 mm g.i. strip direct in ground including digging the trench, laying of strip and refilling the trench, making good the damages, connections etc. as required., supplying installation, testing and commissioning of 32 a rating, double pole, side handle type changeover switch in sheet steel enclosure suitable for operation on 240 v,1-phase, 50 hz ac supply including interconnections , complete as required (bsnl approved makes)., replacement / supplying & laying of 2 x 6 sq mm pvc insulated, pvc sheathed copper conductor armoured cable of 1.1kv grade on surface/wall i/c making connections, testing etc complete as reqd. (isi make), supplying and fixing of fire bucket set( set of 3 buckets) of 9 litre capacity coloured with fire red paint and written "fire on it including supplying and fixing suitable size ms angle iron frame suitable for 3 buckets having hooks etc. including fixing on wall and filling soft sand in buckets complete as required., supplying and fixing of abc type fire extinguishers of 2 kg (abc powder type map-90) complete with delivery hose, squeeze grip release valve, locking arrangement, pressure gauge, operation manual and bracket complete with installation at site with suitable bracket complete as required (isi), acceptance testing of the 5 kva dg set with initial testing after commissioning of dg set at site for 4 hrs in presence of bsnl representative and final acceptance testing after the initial testing for 8 hours on full load and 1 hour on 10% over load at site as per bsnl a/t performa. all resources (fuel, artificial load arrangement, skilled manpower etc.) required for this acceptance testing shall be arranged by vendor., sub head - ii: ( solar power plant), supplying, installation, testing and commissioning of mono perc solar pv panels for 12.5 kwp solar generation system rating complete as required as per the attached specifications., supplying, installation, testing and commissioning of battery bank of 180 v suitable for 12.5kwp solar pv system comprising of 90 nos.. 2v - 200 ah rating vrla batteries, battery rack, protections, dc distribution board, suitable teflon cabling for interconnections,