Web Analytics Made Easy - StatCounter

Annealed Wire Tenders

Get complete information related to latest Annealed Wire Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Annealed Wire Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Annealed Wire Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :44818484 Due date: 05 Jun, 202605 Jun, 2026 NA
Tender For corrigendum : providing e.c. bags, m.s. annealed wire, jumbo bags, nylon rope, dewatering etc. weaving of wire netting, hiring charges of jcb machine, poclain machines etc. which will be used during the flood season of 2026 for strengthening the embankments and p

CTN :45421995 Due date: 18 Jun, 202618 Jun, 2026 NA
Tender For supply of lt panel consisting with 4-pole draw out acb 1000a, 50ka, microprocessor based sr18g, mdo type-02 nos as incoming, acb 1000a, 50ka, microprocessor based sr18g, drawout type-01 nos as bus coupler with 4 pole 400a 50-56ka microprocessor based mccb-05 nos, 4 pole 250 a 36-37ka microprocessor based mccb-05 nos and 4 pole 100a 25ka microprocessor based mccb-02 nos as outgoing with suitablecu. busbar metering voltmeter, ammeter, energy meter on incoming side and ammeter with selector switch, hrc back up fuse in outgoing side and protective circuit & sheet steel enclosure, appropriate spreader kink for mccb and mechanical/electrical interlocking for acb with necessary item for seal the cable entry andoutgoing point. ]

Central Government/Public Sector

CTN :45391523 Due date: 04 Jun, 202604 Jun, 2026 NA
Tender For supply, installation, testing and commissioning of 8way ip 54 rated vertical double door tpnmcb db ,a) 1 nos. of 200a, 36ka, fp, mccb as incomer, b) 3 nos. of 32a, 18ka, tp mcb and 6 nos. of 6a, sp, mcb and 9 nos. of 16a, sp, mcbs as outgoing, cable adapter with standard specifications. preferred make; l&t, c&s, havells, abb, or similar. [ warranty period: 30 months after the date of delivery ] ]

CTN :45048307 Due date: 30 Jun, 202630 Jun, 2026 NA
Tender For corrigendum : : supply, installation, testing & commissioning of electrical equipment for dg block 119a of inrp - ht panels (119a)supply, installation, testing & commissioning of indoor type floor mounted, single front, metal clad, 1250 a, 6.6 kv, 3 phase, 3 wire, vcb switchgear panel suitable for a short circuit current of 31.5 ka for 3 seconds, internally arc tested for 31.5 ka for 1 second, comprising of following incoming & outgoing feeders : incoming feeder: 1 no. 1250 a, 3p vcb outgoing feeders: i) 7 nos. 630 a, 3p vcbii) 1 no. 1250 a, 3p vcb as tie feederwith surge arrestors, relays, pts, cts & other necessary accessories including associated structural steel required for complete installation of the panel & equipment earthing of the panel from both the earthing terminals of the panel to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings. reference drg. nos: ip1/119a/05027339/dwg/001/r0 & ip1/119a/05027339/dwg/002/r0(note: terminal box of each incomer of 6.6kv switchboard shall be suitable for terminating 4x3cx400 sq.mm., 6.35/11kv (e), a2xwy cables.), supply of spares for ht panels as per attached spares list mentiond in section c, part ii of tender, 2.5 mva, 6.6/0.433 kv dry type transformers (119a)supply, installation, testing & commissioning of 6.6/0.433 kv, 2.5 mva, dyn11 dry type cast resin transformer having percentage impedance of 8.5% complete with ht cable end box, lt bus duct flange, off load tap changer on ht side with range of +/-5% in steps of 2.5%, wti scanner, ct for restricted earth fault protection and other necessary accessories including associated structural steel required for complete installation of the transformer & equipment & neutral earthing of the transformer from both the earthing terminals of the transformer to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings.reference drg. no. : ip1/119a/05034347/dwg/001/r0, supply of spares for dry type transformers as per attached spares list mentiond in section c, part ii of tender, 2000 kva diesel generator sets (119a)supply, installation, testing & commissioning of 3 phase 2000 kva prime power 433v, 50hz, 0.8 p.f. diesel-generator sets with 110% overload capacity for 1 hr with four (4) stroke inline or vee type cylinder arrangement having engine speed 1500 rpm, 24v electric battery starting system with a provision of interchangeability of battery bank between two dg sets, complete with all auxiliary equipment including amf control panel, auxiliary mcc panels, heat exchanger cooling system, raw water pump, remote radiator with fans on terrace, ms exhaust piping, exhaust structure (maximum 30 m stack), 4 nos. of 3.6 cubic metre fuel day tank outside dg building (for all 4 dg sets) & 1 no. of 990 ltr intermittent tank inside each dg room, ms "c" class fuel piping between engine & fuel tank, dg room accoustic treatment & complete ventilation of dg room, brushless excitation for alternator, one no. 3200 amp 415 v 4p acb, ms structural steel supports/ channels/ angles & other necessary accessories including associated structural steel required for complete installation of the dg & equipment & neutral earthing of the dg from both the earthing terminals of the dg to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & necessary statutory clearances from cpcb etc. as required and as per tender technical specifications & drawings. design and construction of foundation for exhaust pipe rack/ structure of dg set is included in the scope of the contractor.reference drg. nos. : i) ip1/119a/05034347/dwg/001/r0ii) ip1/119a/05044831/dwg/003/r0iii) ip1/119a/05044831/dwg/004/r0iv) ip1/119a/05044831/dwg/005/r0v) ip1/119a/05044831/dwg/006/r0, supply of sp

Central Government/Public Sector

CTN :45252253 Due date: 12 Jun, 202612 Jun, 2026 NA
Tender For corrigendum : supply of supply part for retrofitting of lt panel by supply and installation , service part for retrofitting of lt panel by supply and installation , supply of main incoming lt power distribution panels slipway , install, replace, test and commissioning of main incoming lt power distribution panels slipway , supply of welding and lighting panels slipway , install, replace, test and commissioning of welding and lighting panels slipway , supply of 3.5c x 400 sq.mm aluminum cable from substation-02 to slipway , laying, fixing, testing and commissioning of 3.5c x 400 sq.mm aluminum cable from substation-02 to slipway , supply of 3.5cx 185 sq.mm aluminum cable from slipway-2 and 3 main incoming panels to welding and lighting panels , laying, fixing, testing and commissioning of 3.5cx 185 sq.mm aluminum cable from slipway-2 and 3 main incoming panels to welding and lighting panels , supply and fitment of suitable end termination kits - straight through joints kits of required quantity to all the incoming and outgoing cables at both ends of slipway-02, slipway-03, substations, etc , providing earth pits with 75mm ci pipe as is standards , supply and laying of gi flat 50 x10 mm necessary joints with nut and bolts from earth pit to panel boards , repair and excavation of cable trench of 75mm thick up to 90cm depth , fixing of perforated cable tray on slipways 02 and 03 and securing of cables with metal ties and capping and casing to be provided , foundation for all lt panels i.e. steel foundations with concrete pedestal for panels all incoming and welding and lighting panels

State Government

CTN :45359840 Due date: 15 Jun, 202615 Jun, 2026 10.46 Lacs
Tender For construction of new 11kv out going power cable trench, loops, renovation and height upliftment of existing outgoing trench and loops and tit bit other civil works at old nimpura 33/11 kv sub-station under kharagpur division in paschim medinipur regio

State Government

CTN :45359850 Due date: 15 Jun, 202615 Jun, 2026 35.23 Lacs
Tender For construction of outgoing cable trench, development of switchyard and repair of control room building, boundary wall and other ancilary civil work at pirakata 33/11 kv sub-station under medinipur division, dist paschim medinipur

CTN :45338135 Due date: 15 Jun, 202615 Jun, 2026 NA
Tender For supply, erection, testing & commissioning of lt panel consisting of 400a 50ka 4 pole microprocessor based mccb - 02 nos as incoming , 200a/250a 36ka 4 pole microprocessor based mccb-03 nos, 63a 36ka 4 pole microprocessor based mccb-02 nos and 63a 10ka dp 2pp mcb - 02nos as outgoing, all mccbs shall be with rotary switch, with voltmeter,ammeter, led indicator lamp,cu. bus bar , neutral link, earth bar, spreader link, lock and key feature arrangement cable gland etc. with suitable sheet steel enclosure conforming to cege/grc's specification no. ser/elec/gs/description/ltpanel/1/rev-0/mar2024 or latest.minimum size of panel 1800 mm (h)x 2400mm (l) x 600 mm(d). [ warranty period: 30 months after the date of delivery ] ]

CTN :45322644 Due date: 01 Jun, 202601 Jun, 2026 8.70 Lacs
Tender For supply, installation, testing and commissioning of phase wire and street light and vairious electrical equipment needed for implementation of budget announcement 2025-26 - providing & fixing of ik08, ip 66 protected led street light luminaire on existing bracket/pole. fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with uv stabilized pc (uv stablization report submitted for uv cover ) /toughened glass cover and secondary lens on each led & should be smd type of 3 to 5 watt each . the system efficacy >=125 lm/ wt and potted driver & has a unique bis r number with input voltage ac 120 to 270 v ac with high voltage cutoff @>=300 v ac and auto resetting safety , power factor >0.95 driver efficiency >85% ,thd(i) 70 and cct 5700k +355k. surge protection shall be min 4 kv internal and min 10 kv external inside driver compartment. driver should be phase to phase protection of 440 v for 4 hrs. manufactures word mark/name engraved/embossing on die cast housing to allow traceability/authenticity. fixture shall be as per is 10322 complianced.oem must have its own in, led street light fixture with minimum lumen output 5600 lm, sitc of ip-42 and general construction confirming to is:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-(a)thickness of crca sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided(b)complete panel shall undergo a process of degreasing, water rinsing, activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then powder coated with approved shade of minimum 70 microns on both side of panel. the panel having pe foam/ neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c) interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . control wiring will be carried out with 1.5 sq.mm, earth wire with 2.5 sq.mm and ct with 2.5 sq.mm flexible copper wire only. all joints / interconnections of copper bus bar shall be dully tinned . clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar bus bar is insulated by heat shrinkable sleeves . earth and neutral bus bar shall be half of the size of phase bus bar. ( cost of bus bar / flexible wire for interconnection between main busbar and switchgear is to be paid extra )(d)wiring between components within switchgear and incoming / outgoing cable shall be done through the terminal block only. direct connection shall not be permitted. each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. for tap-offs, adjacent terminals with shorting strips shall be used. 10% spare terminal blocks shall be provided. wire identification on marking strip shall correspond to the designation of the wiring diagrams. all wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram.(e)all wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, wiring between terminals of various devices shall be point to point (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.(f)floor mounted panel sh

CTN :45335488 Due date: 28 May, 202628 May, 2026 NA
Tender For supply of customized junction box made of 14 swg g. i. sheet size: 450mm x 350mm x 250mm complete with hinged door and locking system and providing 4 bolt terminal arrangement - 100amp suitable for power distribution, providing 3 nos. cable entry/exit holes suitable for incoming & outgoing cables of size 50 sq.mm - 2 nos. and 35 sq.mm - 1 no. also scalable a space for 1 no. 63 amps. mccb, along with aluminium strip of size 2.5 mtrs. x 0.05 mtrs. 2 inch wide 2 nos. make: indigenous/similar. [ warranty period: 30 months after the date of delivery ] ]
 Loading, Please wait...

Connect us via What's Up