Get complete information related to latest Antenna Tower Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Antenna Tower Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Antenna Tower Repair Tenders.
Tender For nit for construction of rr masonry revetment wall at tower loc. no. 290 (fd0) of 400 kv bina-bhopal dcds line, loc. no. 174 ( (c+3m) of 220 kv malanpur- mehgaon/auriya dcds line, loc. no. 173 (bo), 184 (bo), 229 (b30) of 220 kv katni-maihar/satna line, loc. no. 25 (nd0+5 m), 26 (nd), 27 (nd), 28 (nd) of 132 kv sabalgarh-vijaypur dcds line & loc. no. 157 (d0+3 m) of 132 kv katni- panagar line under eht-maint., division, gwalior, bina & damoh and construction of rcc revetment wall at loc. no. 337 (fd0+3 m) of 400 kv bina-bhopal dcds line & loc. no. 128 (x+3 m) of 132 kv bina-sagar old transmission line under eht-maint., division, bina as per tender specifications. all material like cement sand, metal, rr stones, reinforcement bar, ac pipes, water, etc. along with transportation of men & material t&p etc. shall be arranged by the contractor at his own cost.
Tender For work of erection of tower for shifting/height raising & conductor replacement between loc. no. 74-79 of 132kv d/c popda-bhestan line approved under r&m plan 2024-25 under ichhapore transmission division
Tender For conducting revenue survey and preparation of lps and related documents for assessment of land compensation along transmission corridor of 765 kv dc line on dc tower from virudhunagr 765 kvss to proposed coimbatore 765 kv ss
Tender For miscellaneous civil works for maintaining adequate ground clearance and protection of tower foundation in 132kv bhowali-kathgodam transmission line under 220kv oandm division, ptcul, haldwani
Tender For corrigendum : the work of replacement of rusted tower no 109c of 132 kv moradabad rampur ckt line at 132 kv sub station rampur under electricity transmission division rampur
Tender For corrigendum : bi-arc for the emergency restoration of power of 66kv,132kv & 220kv transmission line on tower and h-frame structure.(re-invite)
Tender For corrigendum : construction of diversion weir at the offtake point of the markandeya river at pachapur village to create a pool of water to divert the water from the river to the main pump house though the intake channel. supply, installation, testing and commissioning of pumping machinery of balance 03 nos out of (5w plus 1s) of vt of capacity 2830 hp to carry discharge of 0.914 cumecs at 187.8 m head along with electrical works for the main pump house. design, supply, erection, testing and commissioning of one power transformer of adequate capacity of 15 mva to meet the load requirement of main pump station for 110kv/6.6kv. construction of balance rising main for 4.752 km of pipe dia 1500 mm to 1200 mm in the main pump house from ch 18.830 km to ch 23.582 km at the delivery chamber-2 near mallapur village with necessary valves, chambers, crossings, thrust and anchor blocks. construction of bleeder of length 0.747 km, which conveys the discharge of 1.67 cumecs from the raising main at ch 19.377 km to delivery chamber-1 proposed adjacent to second pump house at hanabaratti village. construction of delivery chamber 1 adjacent to second pump house near hanabaratti tank. construction of second pump house and its allied works. supply, installation, testing and commissioning of pumping machinery with 3 nos (2w plus 1s) of vt of capacity 1500 hp to carry peak discharge of total 1.67 cumecs at 110 m head, along with electrical works for the second pump house. construction of pressurized bulk feeder no.4 of length 12.2 km, from the end of manifold system of second pump house to delivery chamber-3 at suthagatti village with necessary valves, chambers, crossings, thrust and anchor blocks, surge analysis & surge protection works. construction of delivery chamber - 2 at the end of rising main near mallapur village. construction of delivery chamber - 3 near suthagatti village, at the end of pressurized bulk feeder - 4 taking off from second pump house. supply, jointing, laying, testing and commissioning of pipe distribution network consisting of bulk feeder lines, mains, sub mains and sub feeders with ms/hdpe pipes of required pressure rating for conveying water under each blocks up to 20 ha sub chak, with necessary valves, chambers, crossings, thrust and anchor blocks. construction of security quarter, approach road and protection works all around the second pump house layout. construction of service road along the pipeline alignment for bulk feeders and main lines. transmission line from source sub stations to the second pump house with a switch yard with receiving tower,33kv vcb circuit breaker,33/6.6kv power transformers,6.6kv incomer ht pannel,110vdc battery and battery charger with dcdb,6.6kv 150kvar bus capacitor pannel,6.6/0.415kv auxiliary transformer,6.6kvht soft stater panel with capacitor,415v lt pcc pannel,6.6kvht electrical motors, lt load, other general items and safety accessories. operation and maintenance of the scheme for 5 years.
Tender For corrigendum : de-stringing of acsr zebra conductor for dead circuit of 220 kv kunihar-pinjore transmission line from tower no. 335 to 336 at baddi district solan (h.p)
Tender For providing of custom bid for services - shifting of tower location number 70 of 132 kv tezunamsai transmission line under tezu tlm with 132kv dd6 tower