Tender For supply of auxiliary contactor for 415v ok (k-23) contacts: 3 no + 1 nc, control voltage: 168 -300v acconfirming to bom for switchboard cabinet (s1), sr. no. 104 of rdso specification no. rdso/pe/spec/0184-2015(rev-0). [ warranty period: 30 months after the date of delivery ] ]
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - onboard p15a class of ships; irc for replacment of gpus for switchboard fitted onboard p15a class of ships; service provider
Tender For corrigendum : supply of hv switchboards c c - supply 6.6kv switchboard at manmad pumping station tag no-hv swbd-1-manmad as per mr sl. no. 1.1 , supply 6.6kv switchboard at manmad pumping station tag no-hv swbd-2-manmad as per mr sl. no. 1.2 , mandatory spares for hv swbds at manmad terminal as per mr sl. no. 1.3 , supply 6.6kv switchboard at sanghvi pumping station tag no-hv swbd-1-sanghvi as per mr sl. no. 1.4 , supply 6.6kv switchboard at sanghvi pumping station tag no-hv swbd- 2-sanghvi as per mr sl. no. 1.5 , supply 6.6kv switchboard at sanghvi pumping station tag no-hv swbd-3-sanghvi as per mr sl. no. 1.6 , mandatory spares for hv swbds at sanghvi terminal as per mr sl. no. 1.7 , supply 6.6kv switchboard at gujri pumping station tag no-hv swbd-1- gujri as per mr sl. no. 1.8 , supply 6.6kv switchboard at gujri pumping station tag no-hv swbd-2-gujri as per mr sl. no. 1.9 , mandatory spares for hv swbds at gujri pumping station as per mr sl. no. 1.10 , supervision of installation work at manmad as per mr sl. no. 1.11 , performing testing and commissioning activities at manmad as per mr sl. no. 1.12 , supervision of installation work at sanghvi as per mr sl. no. 1.13 , performing testing and commissioning activities at sanghvi as per mr sl. no. 1.14 , supervision of installation work at gujri as per mr sl. no. 1.15 , performing testing and commissioning activities at gujri as per mr sl. no. 1.16 , on call visit charges for amc for 1st year at manmad as per mr sl. no. 1.17.1 , testing kit mobilizing charges for 1st year as per mr sl. no. 1.17.2 , on call visit charges for amc for 2nd year at manmad as per mr sl. no. 1.17.3 , testing kit mobilizing charges for 2nd year as per mr sl. no. 1.17.4 , on call visit charges for amc for 3rd year at manmad as per mr sl. no. 1.17.5 , testing kit mobilizing charges for 3rd year as per mr sl. no. 1.17.6 , on call visit charges for amc for 1st year at sanghvi as per mr sl. no. 1.18.1 , testing kit mobilizing charges for 1st year as per mr sl. no. 1.18.2 , on call visit charges for amc for 2nd year at sanghvi as per mr sl. no. 1.18.3 , testing kit mobilizing charges for 2nd year as per mr sl. no. 1.18.4 , on call visit charges for amc for 3rd year at sanghvi as per mr sl. no. 1.18.5 , testing kit mobilizing charges for 3rd year as per mr sl. no. 1.18.6 , on call visit charges for amc for 1st year at gujri as per mr sl. no. 1.19.1 , testing kit mobilizing charges for 1st year as per mr sl. no. 1.19.2 , on call visit charges for amc for 2nd year at gujri as per mr sl. no. 1.19.3 , testing kit mobilizing charges for 2nd year as per mr sl. no. 1.19.4 , on call visit charges for amc for 3rd year at gujri as per mr sl. no. 1.19.5 , testing kit mobilizing charges for 3rd year as per mr sl. no. 1.19.6 , site training for hv swbds supplied at manmad as per mr sl. no. 1.20 , site training for hv swbds supplied at sanghvi as per mr sl. no. 1.21 , site training for hv swbds supplied at gujri as per mr sl. no. 1.22 , unit rates for test as per attached annexure-1 as per mr sl. no. 1.23 , unit rates for 2 years o and m spare as per clause no. 4.5.3 as per mr sl. no. 1.24
Tender For corrigendum : tender for supply of switchboard mv indoor with vcb breaker c c -for item title description refer mr , for item title description refer mr , for item title description refer mr , for item title description refer mr , for item title description refer mr , for item title description refer mr , for item title description refer mr , for item title description refer mr , for item title description refer mr , for item title description refer mr , for item title description refer mr , for item title description refer mr , for item title description refer mr , for item title description refer mr , for item title description refer mr , for item title description refer mr , for item title description refer mr , for item title description refer mr , for item title description refer mr , for item title description refer mr , for item title description refer mr , for item title description refer mr , for item title description refer mr
Tender For corrigendum : : supply, installation, testing & commissioning of electrical equipment for dg block 119a of inrp - ht panels (119a)supply, installation, testing & commissioning of indoor type floor mounted, single front, metal clad, 1250 a, 6.6 kv, 3 phase, 3 wire, vcb switchgear panel suitable for a short circuit current of 31.5 ka for 3 seconds, internally arc tested for 31.5 ka for 1 second, comprising of following incoming & outgoing feeders : incoming feeder: 1 no. 1250 a, 3p vcb outgoing feeders: i) 7 nos. 630 a, 3p vcbii) 1 no. 1250 a, 3p vcb as tie feederwith surge arrestors, relays, pts, cts & other necessary accessories including associated structural steel required for complete installation of the panel & equipment earthing of the panel from both the earthing terminals of the panel to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings. reference drg. nos: ip1/119a/05027339/dwg/001/r0 & ip1/119a/05027339/dwg/002/r0(note: terminal box of each incomer of 6.6kv switchboard shall be suitable for terminating 4x3cx400 sq.mm., 6.35/11kv (e), a2xwy cables.), supply of spares for ht panels as per attached spares list mentiond in section c, part ii of tender, 2.5 mva, 6.6/0.433 kv dry type transformers (119a)supply, installation, testing & commissioning of 6.6/0.433 kv, 2.5 mva, dyn11 dry type cast resin transformer having percentage impedance of 8.5% complete with ht cable end box, lt bus duct flange, off load tap changer on ht side with range of +/-5% in steps of 2.5%, wti scanner, ct for restricted earth fault protection and other necessary accessories including associated structural steel required for complete installation of the transformer & equipment & neutral earthing of the transformer from both the earthing terminals of the transformer to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings.reference drg. no. : ip1/119a/05034347/dwg/001/r0, supply of spares for dry type transformers as per attached spares list mentiond in section c, part ii of tender, 2000 kva diesel generator sets (119a)supply, installation, testing & commissioning of 3 phase 2000 kva prime power 433v, 50hz, 0.8 p.f. diesel-generator sets with 110% overload capacity for 1 hr with four (4) stroke inline or vee type cylinder arrangement having engine speed 1500 rpm, 24v electric battery starting system with a provision of interchangeability of battery bank between two dg sets, complete with all auxiliary equipment including amf control panel, auxiliary mcc panels, heat exchanger cooling system, raw water pump, remote radiator with fans on terrace, ms exhaust piping, exhaust structure (maximum 30 m stack), 4 nos. of 3.6 cubic metre fuel day tank outside dg building (for all 4 dg sets) & 1 no. of 990 ltr intermittent tank inside each dg room, ms "c" class fuel piping between engine & fuel tank, dg room accoustic treatment & complete ventilation of dg room, brushless excitation for alternator, one no. 3200 amp 415 v 4p acb, ms structural steel supports/ channels/ angles & other necessary accessories including associated structural steel required for complete installation of the dg & equipment & neutral earthing of the dg from both the earthing terminals of the dg to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & necessary statutory clearances from cpcb etc. as required and as per tender technical specifications & drawings. design and construction of foundation for exhaust pipe rack/ structure of dg set is included in the scope of the contractor.reference drg. nos. : i) ip1/119a/05034347/dwg/001/r0ii) ip1/119a/05044831/dwg/003/r0iii) ip1/119a/05044831/dwg/004/r0iv) ip1/119a/05044831/dwg/005/r0v) ip1/119a/05044831/dwg/006/r0, supply of sp
Tender For providing and fixing of various necessary electrical material on rental basis for temporary lighting on the occasion of various religious cultural national programs for the year 2026-27-description of items: watertight halogen lamp (1000/500 watts)—including temporary wiring and service line; led light fitting (120/150/200 watts)—including temporary wiring and service line; emergency generator set (5 kw)—including fuel, operator, and changeover switch; emergency generator set (7.5 kw)—including fuel, operator, and changeover switch; emergency generator set (15 kw)—including fuel, operator, and changeover switch; emergency generator set (25 kw)—including fuel, operator, and changeover switch; emergency generator set (63 to 100 kw) with canopy—including fuel, operator, and changeover switch; strip series lights; sound system—including horn speakers, cassette/cd player, microphone stand, control box, operator, and other accessories; tower lamp (20 ft height)—with led fittings (10/12 units, 250/300 watts) and temporary wiring; colored tube lights; colored led par lights; china series lights; podium—including microphone stand and microphone cable; pipe series lights; led flood light fitting (150/200 watts)—white; led flood light fitting (150/200 watts)—colored; fans (pedestal and ceiling); medium-sized air cooler; bulb holder (100 watts) / led bulb (30 watts); led tube light strip (28 watts); service line; led screen (size: 8x10 ft); projector with screen; extension board (6 amperes). 3-switch socket, 16 amp power plug, switchboard, microphone, dais, sharpie light
Tender For supply of auxiliary contactor for 415v ok (k-23) contacts: 3 no + 1 nc, control voltage: 168 -300v acconfirming to bom for switchboard cabinet (s1), sr. no. 104 of rdso specification no. rdso/pe/spec/0184-2015(rev-0). [ warranty period: 30 months after the date of delivery ] ]