Tender For corrigendum : centralized rate contract for three years for supply of dry chemical powder (dcp) and aqueousfilmformingfoam (afff) (3 percent concentration) for the installations in offshore and onshore areas of ongc
Tender For following works shall be carried out quarterly during the contract period for the two identical sets of co2 flooding system at mghe power house. the one set of system for carting to the units-1,2,3&4 and the second set of system for carting to units-5,6,7&8. i)cleaning of heat detector externaly with dry cloth ii)ensure working condition of heat detectors iii)cleaning of smoke detector externaly with dry cloth iv)ensure working condition of smoke detectors v)simulate heat and smoke detector simultaneously and check for cross zone vi)checking for leakage in pilot cylinder vii)checking the weight of co2 pilot cylindersviii)check the condition of co2 pilot hose ix)check the condition of co2 discharge hose x)inspect pressure switch and check for its functioning xi)inspect maual call points and check for its functioning xii)inspect abort switch and check for its functioning xiii)inspection of online weigh monitor and check for its functioning xiv)inspect hooter with strobe and check for its functioning xv)checking for healthiness of the battery xvi)checking the condition for slave nrv xviichecking the condition for master nrv xviii)checking of solenoids. xix)refilling of co2 cylinder and pressure testing 45 kg capacity and 4.5kg capacity (in case release of co2 gas during generator fire incidents) xx)any other work connected with the system not explicitly mentioned shall also be carried out for safe and proper operation of the system. xxi)conducting the demo of operation of the co2 flooding system twice (once in 2 quarter) during the annual maintenance contract period for kpcl staff.
Tender For corrigendum : supply of co2 fire fighting system for grse ars project : : - co2 total flooding fixed ffs_accessories , documentation co2 fffs , on board spares co2 fffs , special tools and comm. spare co2 fffs , 1st submission of binding data_co2 fffs , instl and comm spares for co2 fffs , service for stw - commissioning co2 fffs , preservation with consumbles_co2 fffs , training_co2 fffs
Tender For stored pressure fire extinguishers of mechanical foam type with a capacity of 09 litre, conforming to is 15683:2018 (or latest), designed for effective fire fighting against class b fire and having fire rating of 233 b. the extinguisher shall be constructed from stainless steel materials conforming to clause 9.2.6 of is 15683:2018. the foam concentrate shall be aqueousfilmformingfoam (afff) confirming to is 4989:2018. the unit shall be equipped with flexible hose and foam applicator nozzle. a brass or stainless steel squeeze grip valve shall be provided in accordance with clause 9.3 of is 15683. test certificate from nabl accredited laboratory for the test pressure (pt) of the assembled unit as mentioned in clause 6.1 of is 15683:2018 shall be provided along with supply. each unit shall be supplied with a wall bracket or stand for secure mounting and shall include maintenance instructions for annual inspection by certified personnel. marking shall be as per clause 10 of is 15683:2018 with the year of manufacture permanently engraved or embossed. complete documentation including user manual, warranty, and certification details must be provided with each extinguisher. [ warranty period: 30 months after the date of delivery ] ]
Tender For centralized rate contract for three years for supply of dry chemical powder (dcp) and aqueousfilmformingfoam (afff) (3 % concentration) for the installations in offshore & onshore areas of ongc
Tender For corrigendum : supply & delivery of alcohol resistance aqueousfilmformingfoam for firefighting (ar-afff) for fire department of annual maintenance contract as per tender specificationsand requirements.
Tender For bid to ras providing of refilling of fire extinguisher cylinders - hydrotesting, painting and refilling of co2 flooding system cylinders, co2 fire extinguishers and clean agent fire extinguishers; hydrotesting of co2 (45 kg) cylinders; as per nit,refilling of fire extinguisher cylinders - hydrotesting, painting and refilling of co2 flooding system cylinders, co2 fire extinguishers and clean agent fire extinguishers; refilling of co2 (45 kg) cylinders; as per nit,refilling of fire extinguisher cylinders - hydrotesting, painting and refilling of co2 flooding system cylinders, co2 fire extinguishers and clean agent fire extinguishers; painting of c02 (45 kg) cylinders; as per nit,refilling of fire extinguisher cylinders - hydrotesting painting and refilling of co2 flooding system cylinders co2 fire extinguishers and clean agent fire extinguishers; hydrotesting of co2 22.5 kg cylinders; as per nit,refilling of fire extinguisher cylinders - hydrotesting painting and refilling of co2 flooding system cylinders co2 fire extinguishers and cl