Web Analytics Made Easy - StatCounter

Armor Tenders

Get complete information related to latest Armor Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Armor Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Armor Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :36264701 Due date: 20 Jun, 202420 Jun, 2024 NA
Tender For supply of white armor acs in 300 ml can, for coating of lead acid battery terminals to prevent sulphation, ru sting and oxidation, having blue color code for timely indicative re-application. material to be procured from oem or their authorised dealers only. tenderer has to specify make and product no. in their offer and has to produce a uthorization certificate failing which their offer will be passed over. make- black lotus, pci, svp, ichem, s-tec h or prolific only.

Central Government And Public Sector

CTN :36257423 Due date: 19 Jun, 202419 Jun, 2024 NA
Tender For supply of mattress 78 x 36 x 4inch , blanket 500 gsm warm and super soft light weight single bed mink blanket for winter brown , bedsheet 90 x 54 inch white 100percent cotton flat single size bedsheet 90 x 54 inch white , pillow adjustable microfiber pillow set 16x24 inches white my armor height adjustable microfiber pillow 16 x 24 inches white , pure cotton pillow covers 300 thread count with satin stripe 17 x 27 inches , towel white cotton microfiber bath towel towel type bath size 30 inch x 60 inch 1 towel gsm 580 , napkin size 14 x 21 inch white colour cotton material , plastic doormat , cotton doormat bathmat green 45x60 cm rectangular

CTN :35790062 Due date: 29 Jun, 202429 Jun, 2024 NA
Tender For corrigendum : supply of ste mode on hvf - lv1 r72 434-06-004sb-1 flap armor right hand , lv1 r72 527-08-70-1129 oil seal 40x60x10 , lv1 r72 527-08- 70-0141 arm assy , lv1 r72 229-06-090 blade drg no 527 0870 6005 , lv1 r72 229-06-034 jimmy , lv1 r72 5330019734 gasket , lv1 r72 4720015064 hose 4ou16-7 bor dia16mm walthk 4.0mm , lv1 r72 4730077745 plug drg no 307-002 , lv1 r72 gost 7808-70 oh 3562 bolt 3m12-6gx35.66.016 , lv1 r72 gost 5496-78 roh 2751 pipe 10x2x96-4c , lv1 r72 gost 5496-84 pipe4.5x1.3x14- 4c b dia4.5mmwalthk1.3mm , lv1 r72 54-83-158 label , lv1 r72 175-70-006 shield , lv1 r72 tu 005-6016-87 oh 3378 hose 40u16-13 or 40u16-7 bore dia 16mm wallthickness 4.0mm , lv1 r72 172-70-490 cover , lv1 r72 54-42-243 gasket , lv1 r72 172-60-147 body , lv1 r72 5306056997 bolt m10-6gx20-66.016 spcn no gost- 7808-70 , lv1 r72 geo-344-108tu plug shrg 20p21sh6 , lv1 r72 ost3-408-70 oh 3799 clip 68-74-1 , lv1 r72 gost 17473-80 oh 3637 screw am 1.4-6gx8.46.016 , lv1 r72 172-93-389-01 cover plate , lv1 r72 5306056991 bolt 3m10-6gx35-88-38xc-016 , lv1 r72 gost 17473-80 oh 3640 screw am2-6gx16.46.016 , lv1 r72 gost 9650- 80 oh 3763 pin6-16f9x36.38xc.2.35.5-45.5chem oiled , lv1 r72 54-42-241 insulator , lv1 r72 5306057012 bolt 3m16x40-66-016 , lv1 r72 etu 500 oh 3443 ball 6,35- 200 , lv1 r72 gost 17473-80 oh 3639 screw am2- 6gx14.46.016 , lv1 r72 gost 10450-78 oh 3830 under size washers 16.5x1.01.016 , lv1 r72 5306057008 bolt 3m12x1.25-6gx20.66.016 , lv1 r72 5306-056900 bolt 3m6-6gx25-88-38xc-016 spcn no gost-7805-70 , lv1 r72 tu-005-6016-80 hose 40u10-13 bore dia 10mm wall thk4mm , lv1 r90 2510008783 lh panel with plates , lv1 r90 5306061057 bolt 3m8x1-6gx55.66.016 , lv1 r90 3020016042 gear drg no 447a-17-011

CTN :36216087 Due date: 17 Jun, 202417 Jun, 2024 NA
Tender For supply, installation, testing & commissioning of set of indoor type vcb panel of 22 nos (06 nos i ncoming, 15 nos outgoing and 01 nos bus coupler) as per enclosed "cee/grc's specification no.- el/con/33 /11/6.6kv/6 kvvacuum-cb/1/2015", rated voltage 12kv, normal current 1250 amps, rated short circuit brea king current ( aginst clause 1.3 of annexure a of referred specification) shall be 40 ka. impulse test voltage (pea k) of 75kv and power frequency test voltage of 28kv (rms) shall be applicable in clause 1.6 of annexure a of ref erred specification. the enclosure shall provide at least the degree of protection ip 53. the oem's type test certif icate of switchgear for extended mechanical endurance class m2 and extended electrical endurance class e2 as per iec 62271-100 are to be furnished along with supply of materials. vcb panels shall be provided with a com mon bus bar set of 2 bars of size 100mmx12mm per phase. busbars will be made out of electrolytic copper of 9 9.9% purity. cts, pts and all other accessories shall be provided as per clause 4.2 to 4.4 of annexure a of referr ed specification. tri-vector meter, ammeter and voltmeter mentioned in clause 4.4 shall have digital display and shall be of modbus rs 485 port, accuracy class 0.5s as per is 15959 latest, power supply -230v ac. microproc essor based numerical protection relay, in addition to clause 4.4 & 6.2 under annexure-a, shall have 4 nos. selec table idmt curves for current-time characteristics. it shall have lcd display to display settings, trip records and also real time & date. it shall record 30 trip records with time and date & shall be provided with modbus rs485 po rt to communicate trip records and protection setting. battery charger and battery under clause 5.0 of annexure a of referred specification will not be required and is not covered under scope of supply. cable glands of stainles s steel are to be provided for all the cable entry holes, cable glands will be suitable for entry of cable and terminati on of armor of cable. cable entry for shall be from bottom only and for this- removable gland plate of thickness 3 mm (minimum) shall be provided as per drawing approval. 44 nos. of insulating mats of class b type conformin g to is 15652 latest, 1.5m (minimum) length & width are to be provided. 02 nos. earthing terminals are to be provi ded on each panel. all fasteners shall be of stainless steel. all meters, indication lamp shall have individual name plate on the front panel. necessary spares should be supplied as per attached annexure -c. the technical data sheet (annexure-b) must be submitted duly filled by the tenderers. work involves removal of existing sf6 & vc b panel including civil work as per annexure-ii. removed vcbs shall be shifted to place as directed by the consi gnee within 1 km. the price shall include transportation of vcb panel to the work site including all loadings and u nloadings without causing any damage of materials. designs/ drawings shall be submitted as per clause 5.1 to 5 .6 of referred specification and also the following for approval of dy.cee/ws /kgpws. a) technical data sheet b ) fully dimensional general arrangement drawing complete with plan, elevation and sectional views, location of ca ble entry for incoming and outgoing feeders. c) complete bill of material clearly indicating nos., rating, make, mod el no etc. of all components/ subassemblies/bought-outs etc. d) foundation drawing and cable entry details. e) s chematic wiring diagrams for all power, control, protection and indication circuits. f) manufacturers' catalogue/ tec hnical literature etc. for numerical relays and other bought-out items. tc & gc as per irs terms & conditions sh ould be supplied along with the material. [ warranty period: 30 months after the date of delivery ]

State Government

CTN :36136284 Due date: 13 May, 202413 May, 2024 2.00 Lacs
Tender For equipments required in the poultry unit - debeaking equipment, individual egg candler, trap nest, vernier callipers, screw gauge, maxmum-minimum thermometer, psychro-meter, feeder-chick, feeder-grower, feeder-layer, drinker-chick, drinker-grower, drinker-layer, automatic vaccinator, egg ray, brooder-electric, gas brooder, leg bands, wing bands, flame gun, supplement weighing scale, gum boot
 Loading, Please wait...

Connect us via What's Up