Get complete information related to latest Auctioning Service Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Auctioning Service Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Auctioning Service Tenders.
Tender For providing of repair and overhauling service - fm200 gas sample analysis for purity test from nabl accredited laboratory against dl sl e049 onboard icgs c148 at goa; make ms tyco and model fm200 system; no; buyer premises
Tender For engagement of expert manpower for commissioning, pg test of cpu system u#1 including service and regeneration area at 3x800 mw pvunl patratu site
Tender For providing of repair and overhauling service - modification of test stand for fuel system units; test stand for fuel system units; yes; buyer premises
Tender For supply of 11 kv 24 panel switch board - design engineering manufacturing shop testing inspection packing delivery to site of 11 kv switchboard , spare incomer breaker with trolley and 3 phase line pt mounted , spare outgoing breaker with trolley of each size and rating , numerical feeder protection and control relay of each type , numerical transformer differential protection and control relay of each type , single phase current transformer for each type and rating , single phase current transformer for differential protection for each type and rating , pt primary fuse of each rating , pt secondary fuse mcb , spring charging motor , surge arresters , tnc control switch , closing coil , tripping coil , ammeter selector switch , voltmeter selector switch , bus support insulator used in bus bar compartment of each type , bus support insulator used in cable compartment of each type , anti pumping relay , dc failure relay , master trip relay , 24 window annunciator , 10 window annunciator , hooter , led indication lamps 110v dc for each colours red yellow biue green clear white amber , led indication lamps 110v ac for each colours red yellow and biue , service test limit switches of each type and rating , limit switches used in vcb of each type and rating , electrical contact grease , installation and commissioning support as per engineering specification cd css 11kv sb es.
Tender For corrigendum : providing of repair and overhauling service - repairing of air conditioning test rig; air conditioning test rig; yes; buyer premises
Tender For corrigendum : providing of repair and overhauling service - repairing of domestic refrigeration test rig; repairing of domestic refrigeration test rig; yes; buyer premises
Tender For purchase of various apparatus/instruments required for department of chemistry, chaudhary ranbir singh university, jind - stirrer the stirrer should be made up of ceramic coated aluminium alloy top with digital speed and temperature control. the stirring speed should be 50-1500 rpm or better. the stirrer should be operational up to a temperature range of 300oc with an accuracy of 1.0oc and ip 42 protection class. the input power should be 600 w or above. the stirrer should be supplied with hemispheric bowl (100 ml= 1 no; 250 ml= 1 no) to replace oil baths and mantles in order to perform clean and safe analysis with round bottom flasks., electronic balance the electronic balance should have a maximum weighing capacity of 200 g or more with a resolution and repeatability of 0.1 mg, and a response time of 5 sec or better. the system should have automatic internal calibration with touch screen display. the system should have internal database capacity of 2500 or more with multiuser password protection feature. , vacuum pumpthe pump should be operational at a maximum power of 65 w or more with a max. vaccum of 99 mbar or more. the pump should be fitted with vacuum and filter cartridge., hot air oventhe inner chamber should be made of stainless steel and the outer chamber should be m.s powder coated. the maximum capacity of the oven should be 100 ml or more. the operational temperature should be between ambient to 250 oc or more with a temperature accuracy of 1o c. pid based digital temperature control., double distillation unitthe unit should be pyrogen free with a distillation water output capacity of 1.5 l/h. the minimum cooling water requirement should be 1lt/min. auto-power cut facility in case of halted supply of water., circulating oil baththe oil bath should be made up of stainless steel with 4 digit 7 segment led display for temperature and time. the bath should have s.s perforated tray for holding flasks. the bath should have a capacity to accommodate flask of 1l. the working temperature range should be +5 to 240 oc (0.1 oc increment) with a temperature stability of 1oc., water baththe water bath should have a capacity of 20 l within built water level sensor. the bath should be made up of stainless steel and supplied with 8 concentric rings. the bath should have digital temperature control with pt100 sensor. the system should have stirring capability with ptfe magnetic bars. , ph conductivity meter operational between a ph range of -2 to 16.00 with a resolution of 0.01 ph and an accuracy of 0.02 ph. 5 points calibration. the ec range should be in between 0.00 to 29.99 s/cm, uv cabinet operational at two uv wavelengths (254 and 365 nm). the cabinet should also be equipped with one visible light. the external body should be coated with ms powder/epoxy., flame photometerapplication: the flame photometer is used for qualitative and quantitative determination of several cations, especially for metals that are easily excited to higher energy levels at flametemperature. these metals include na+, k+, ca2+, ba2+ and li2+.specification requirementmeasuring range na+: 0 to 99.9 ppm k+:0 to 99.9 ppm ca2+ :0-99.9 ppmli2+: 0 to 99.99 ppmsensitivity na+= 0.1 ppmk+ = 0.1 ppmspecificity less than 0.5% interference when concentrations are equal to test sample concentrationsgas control-adjustable with knobsignition system-auto ignition systemflame failure-auto detectiongas cut off-automaticreproducibility-less than 1% coefficient of variation for 20 consecutive samplesusing 10 ppm na set as maximum standardlinearity-less than 1%display led, 12.5 mm (1/2")fuel supply-high-grade propane/butane mixture regulated at approximately30 psiair supply-6 l/min at 12 psi; oil and moisture freerecorder-output 0.05 to 5 v (switchable)operating manuals, service manuals, other manuals should provide user, technical and maintenance manuals in english language list of equipment and procedures required for local calibration and routine maintenance service and
Tender For corrigendum : providing of custom bid for services - service contract for procurement ic calibration for two years of automated pneumatic temperature test bench for ci lab at igstpp jharli jhajjar haryana