Tender For installation and commissioning of lattice mast communication towers, wireless radio bridge antennas, and other necessary equipment at multiple locations, including sidings, check posts and the new gm office,
Tender For tender for supply of utility mapper kit for generating digitized cable maps high power utility mapper kit bluetooth enabled to transfer data to mobile app comprising gnss integrable receiver with rtx performance based on catalyst correction service for upto 2cms horizontal 5cms vertical accuracy mobile app for data acquisition of gnss coordinates of route traced and depth data and digital map generation including cloud data backup map output in kml autocad csv locating receiver with 36 user configurable active multi frequency options including 200hz 512hz 797hz 815hz 8khz 33khz 65khz 82khz 200khz upto 476.2khz passive detection 50hz for power cables radio mode for locating metallic utilities whethe , gnss receiver should be rtk rtx capable providing accuracy generally in range of 10mm horizontal 20mm vertical with up to 2cms 5cms accuracy horizontal vertical with correction hub service for which license should be provided gnss receiver should be light weight not exceeding 350grams and should be mountable directly on utility mapper receiver gnss receiver should be l1 l2 l5 mss multi frequency compatible , soft carry case customised carry bag with designated slots for equipment placement. , straight grounding earthing with extension cable 10 m length , training the user teams
Tender For supply of point to point radio for nav aids sites with antenna and fixture , external surge protection devices for rf antenna , nms software with license , gi pipe 3 meter length and minimum 2 inch diameter , l3 switch 24 port , l2 switch 8 port 10 100 1000 base t l2 switch with 02x 1g sfp ports poe plus managed , 2 port serial to ethernet industrial grade converter , serial cable for interface connectivity from equipment to serial converter , laptop for remote site rf configuration , desktop with ups for nms , cat6 patch cord 03 meter , cat6 a cable , 9u rack as per specification , rj45 connector cat 6a cable with jacket , rj45 crimping tool , lan tester , pvc conduits , supply installation and commissioning charges , 3 years support and warranty , document and training
Tender For bid to ras procurement of radio communication equipment with installation testing and commissioning - digital hand held communication set , base station , digital repeater , spare battery , hands free kit , ups for digital repeater
Tender For repair, maintenance, and installation of plant/ systems/equipments (version 2) - gram panchayat; grampanchayat iso; service provider radio sets, tactical communication system, satgellite communication systems, command and control systems, electronic warfare communication, network infrastructure, navigation and positioning systems, specialized communication equipment - msme exemption
Tender For corrigendum : repair, maintenance, and installation of plant/ systems/equipments (version 2) - 88 acv sqn; acv 193 equipment; buyer radio sets, tractical communication systems, satellite communication systems, command and control systems, electronic warfare communication, network infrastructure, navigation and positioning system, specialized
Tender For design, support, supply, installation and commissioning, training, warranty and annual maintenance contract of medical cyclotron with turnkey (complete scope as per the attached document in specification) - [equipment -medical cyclotron system] medical cyclotron- bunker type, unshielded with 4 numbers niobium liquid target for 18f production (self shielded), 2 numbers niobium liquid target for 68ga production (unshielded or self shielded), 1 number solid target ( for production of 64cu,89zr, 68ga) (unshielded or self shielded) along with necessary operator and personnel safety interlock system, [equipment -medical cyclotron system] 18f based synthesis modulefully automated cassette-based synthesis module with suitable dual vertical hotcell or equvivalent to handle 20 ci of f18 radioactivity (each working chamber) for routine production of 18f based radiopharmaceuticals., [equipment -medical cyclotron system] synthesis research modulegeneral purpose 18f radiofluorination module with suitable dual vertical or equvivalent hot cell, [equipment -medical cyclotron system] solid target irradiation, processing and synthesis systemsolid target processing system with electroplating+recovery of enriched target+purification) automated module for synthesis of radiopharmaceuticals of zr89,64cu, with suitable hot cell (100 mm lead thickness) [separate prices to be provided for hotcell with camera and hotcell with pb glass window for the working chambers of the hotcells], [equipment -medical cyclotron system] fully automatic dispenser (18f)fully automatic dispenser for vial dispensing with suitable hot cell to handle 20 ci of f18 radioactivity, [equipment -medical cyclotron system] dispenser for solid target-based rpone dispenser for solid target-based radio-pharmaceuticals with suitable hot cell to handle minimum of 5 ci of activity., [equipment -medical cyclotron system] 68ga based synthesis module fully automated synthesis module for radio labelling of 68ga produced from cyclotron with suitable dual vertical hot cell or equvivalent [separate prices to be provided with camera and with pb glass window for the working chambers of the hotcells], [quality control system ] hplchplc with autosampler, [quality control system] gas chromatographygas chromatography with fid and autosampler, [quality control system]tlc scanner, [quality control system] ph reader, [quality control system] mca solid state based mca, [quality control system] dose calibratordose calibrator for qc, lead shielding, [quality control system] bet systemendotoxin test system for quality control, [quality control system]bod incubator, [quality control system] l-bench l-bench for target maintainance, [quality control system] l-bench (qc)l-bench for qc of pet radioharmaceutical, [quality control system]laminar flow benches, [radiation monitoring equipment] central radiation monitoring systemsystem includes software for online data acquisition and backup for six months., [radiation monitoring equipment] gamma area monitor gamma area monitor (0-100mr/h), [radiation monitoring equipment] remote probehigh range gamma monitor with remote probe, [radiation monitoring equipment] stack monitoring systemnai detector for on line stack monitoring systemlead castle for stack monitoring probeintegrated radiation monitoring computer system with complete cabling up to the top floor of building.stack monitoring channel local alarm unitssoftware system for stack monitoringmonitor channel connection kitspare parts kit for stack monitor, stacking monitor channels, area monitors, [radiation monitoring equipment]hand & foot monitor, [radiation monitoring equipment] personal pocket dosimeters (digital), [radiation monitoring equipment] portable gamma dose rateportable gamma dose rate meter + contamination probe, [radiation monitoring equipment] portable survey monitor for neutron, [radiation monitoring equipment] remote probe survey neutron monitor (high range), [radiation monitoring equipment] por
Tender For supply of handheld radio set - vertex 136 174 mhz uhf full band 16 channel analog handheld , battery charger suitable for charging tubular lead acid vrla smf flat plate lead acid battery , 1500 mah li polymer spare battery packs for transreceiver , dc adaptor for cdsc , earphone with bionomic , water proof bag for carrying the same equipment