Web Analytics Made Easy - StatCounter

Auto Transformer Starter Repair Tenders

Get complete information related to latest Auto Transformer Starter Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Auto Transformer Starter Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Auto Transformer Starter Repair Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :42554534 Due date: 03 Dec, 202503 Dec, 2025 2.25 Lacs
Tender For corrigendum : repair and servicing of 11 kv vcb panel c.g make including replacement of potential transformer , servicing of vacuum circuit breakers , and replacement of power backup installed at main electrical distribution section of govt. super specaility hos

corporations/Associations/Others

CTN :42982929 Due date: 15 Dec, 202515 Dec, 2025 NA
Tender For auction sale of 420kv cgl ct scrap,420kv cgl ct scrap (without oil & porcelain),245kv cgl ct scrap,420kv cgl cvt scrap (4400pf-3 & 8800pf-3),scrap 390kv & 336kv surge arrestor scrap,scrap 216 surge arrestor scrap,220kv rip bushing scrap,400kvcgl cb damaged interrupter scrap,scrap refrigerator(e waste),copper cable scrap (pvc insulated armored etc),ms scrap (scrap transformer radiator removed from ict-3,etc),gi scrap (opgw cable bits, gi earth wire bits, damper, etc),stainless steel scrap,power cable aluminium scrap (pvc insulated armored power cable),electronic scrap,common electrical scrap (contactor, voltmeter, ammeter, etc),(e- waste) air conditioner scrap,tin scrap (paint boxes, roof sheets),battery scrap-others 42ah,dilo make vacuum pump with motor,rubber waste,plastic waste,scrap contaminated engine oil,empty transformer oil drum,scrap disc insulator,ceiling fan scrap (ceiling fans removed from colony and office)

Central Government/Public Sector

CTN :42956361 Due date: 26 Dec, 202526 Dec, 2025 61.87 Lacs
Tender For provisioning of electrical and mechanical eqpt against ber under ge 862 ews - supply, installation, testing and commissioning of serve controlled voltage stabilizer (confirming to bis 9815 (part-1) 1994, reaffirmation 2019 latest version) three phase, four wire (rybn), 50 hz, naturally oil cooled, outdoor, unbalanced type, cooper wound, metallic body duly power coated with lifting hooks two nos, digital display type, relay free smooth and silent operation with 1st filling of transformer oil up to level having following specification:-(a) capacity 300 kva (b) type - suitable for unbalanced load and unbalanced input(c) input voltage -360v-480v, input frequency 50 hz (d) output voltage - stabilized at any deigned/ desired voltage 415/+-1% (e) rated frequency - 50 hz(f) wave form distortion - nil (g) response time - not to exceed 20 milli seconds(h) sensitivity - (+/-) 1% (j) rate of correction - not less than 6 volt/second between phase and neutral (k) efficiency - more than 95% (l) type of load - three phase, unbalanced type(m) metering - digital display voltmeter/ammeter with multi-functional meter (n) operating temperature - for indoor use upto max ambient temp + 55 c (o) dimmer rating - 450 amp (p) dimension of tanks - as per oem design(q) oil capacity- as per oem design , (r) class of insulation - class f (s) mode of operation automatic/manual (t) winding temperature rise - max 55 c (10 c above operating temp) (u) transformer oil -is 335 marked (v) core-crgo m4 grade/crno (cold roll grain oriented)/ (cold rolled non-oriented)(w) auto transformer (variac) -100 percent copper wound electrolytic grade(x) losses - as per is norms (y) power factor - not less than 0.95(z ) protection - (i) over load protections (ii) short circuit protections (iii) high/low voltage cut off (iv) by pass arrangement in case of emergency (v) single phase sequence change /phase fail protection (vi) earth fault protection(aa) standard fitting & accessories e.g marking plate, lifting lugs, ci rollers, earthing terminals, cable box including suitable platform as reqd on site complete all as as specified & directed., supply, installation, testing and commissioning of serve controlled voltage stabilizer (confirming to bis 9815 (part-1) 1994, reaffirmation 2019 latest version) three phase, four wire (rybn), 50 hz, naturally oil cooled, outdoor, unbalanced type, cooper wound, metallic body duly power coated with lifting hooks two nos, digital display type, relay free smooth and silent operation with 1st filling of transformer oil up to level having following specification:-(a) capacity 100 kva (b) type - suitable for unbalanced load and unbalanced input(c) input voltage -360v-480v, input frequency 50 hz (d) output voltage - stabilized at any deigned/ desired voltage 415/+-1% (e) rated frequency - 50 hz(f) wave form distortion - nil (g) response time - not to exceed 20 milli seconds(h) sensitivity - (+/-) 1% (j) rate of correction - not less than 6 volt/second between phase and neutral (k) efficiency - more than 95% (l) type of load - three phase, unbalanced type (m) metering - digital display voltmeter/ammeter with multi-functional meter (n) operating temperature - for indoor use upto max ambient temp + 55 c (o) dimmer rating - 150 amp (p) dimension of tanks - as per oem design(q) oil capacity- as per oem design , (r) class of insulation - class f (s) mode of operation automatic/manual (t) winding temperature rise - max 55 c (10 c above operating temp) (u) transformer oil -is 335 marked (v) core-crgo m4 grade/crno (cold roll grain oriented)/ (cold rolled non-oriented)(w) auto transformer (variac) -100 percent copper wound electrolytic grade(x) losses - as per is norms (y) power factor - not less than 0.95(z ) protection - (i) over load protections (ii) short circuit protections (iii) high/low voltage cut off (iv) by pass arrangement in case of emergency (v) single phase sequence change /phase fail protection (vi) earth fault protection(aa) standard fi

Central Government And Public Sector

CTN :42970053 Due date: 19 Dec, 202519 Dec, 2025 60.06 Lacs
Tender For providing of facility management services - lumpsum based - nuclear power plant kgs 3 and 4; o&m of electrical work, repairing and rewinding works of 1800kva 6600v slash 433v dry type cast resin transformer refer scope of work; consumables to be provided by s..

Central Government And Public Sector

CTN :42983611 Due date: 06 Dec, 202506 Dec, 2025 27.21 Lacs
Tender For fabrication of electrical and mechanical store in transformer gallery at power house, chamera iii power station, dharwala e office no 136220

CTN :42970123 Due date: 19 Dec, 202519 Dec, 2025 6.49 Lacs
Tender For supply of supply and laying of 4c 50 sqmm copper armoured power cable from transformer to powerhouse at dnlh d d - supplying of the 4core x 50sqmm one length copper armored pvc insulated pvc sheathed xlpe power cable from transformer to power house , supplying of the 200a 3 pole 25 ka molded case circuit breakers mccb , laying and fixing pvc insulated and pvc sheathed xlpe power cable of 1. 1 kv grade on wall surface as required , supplying and making end termination with brass compression gland of cable , supplying and filling in plinth with sand under floors including watering ramming consolidating and dressing complete with all labour materials transport in hilly area , laying one number pvc insulated and pvc sheathed xlpe copper armoured 1. 1 kv cable in existing cement trench removing sand cushioning placing new cable properly with all labour tools , installation of 200a 3 pole mccb on existing db including dismantling old mccb making connections with suitable lugs and cables tightening terminals testing and commissioning as required. , supplying and fixing 400 400 15 mm seasoned wooden board for mounting 200a porcelain kit kat fuse at the powerhouse including cutting drilling anchor fasteners holes. , supplying and installing 200a porcelain kitkat fuse on pre fixed wooden board, including incoming outgoing cable connections with copper lugs , supplying and fixing 200a neutral link suitable for terminating multiple neutral cables in lt distribution system mounted on pre fixed wooden board , removing outer sheath of 4c 50 sqmm copper armoured xlpe cable up to 2 m and terminating each core at energy meter using heat shrink sleeves including supply laying , providing laying and fixing 75 mm dia medium class gi pipe in rcc road with gi fittings including 75 mm trenching refilling with rcc materials and using all necessary machinery tools etc. , cable jointing of existing 4c 50 sqmm xlpe copper armoured cable using approved heat shrink kit including stripping cleaning crimping with copper lugs heat-shrink sleeves sealing insulation materials , supplying and fixing 6 mm multiwall polycarbonate sheet as shed roofing over energy meter enclosure 1 m length plus 1 m projection with gi supports cutting fixing with screws edge channels , making 4 inch hole in lighthouse entrance gate wall 600 mm thick for cable entry using necessary heavy machinery and tools and refilling as required , add extra charges for executing electrical work at dolphin nose lighthouse in hill area considering difficult terrain limited access higher labor effort and transportation challenges , miscellaneous items including ss screws anchor fasteners nuts and bolts as required gi clamps for cable fixing copper lugs and other necessary materials.

CTN :42954291 Due date: 27 Dec, 202527 Dec, 2025 39
Tender For procurement of electrician lab setup and supply of tools, equipment and machineries. - industrial type power wiring for electrical lab, combination set of 1 panel board electrical machine trainer suitable for demonstrating the construction and functioning of different types of dc machines and ac machines single phase and three phase. should be fitted with friction brake arrangement, green chalk board 8 x 4 with fixing clamps, wiring board 3 meter x 1 meter with 0.5 meter projection on the top made up of wood plank and angles, ev charger for home for 2 wheeler 1 phase input, ev charger for 4 wheeler 3 phase input, smart energy meter 3 phase digital, smart energy meter 1 phase digital, stepper motor 1 ph 240 v with digital controller, primary current injection set 1 phase 220v 50 hz output current 200 a min with timer, ceiling fan coil winding machine 1 phase 250v 50 hz with speed control, motor coil winding machine manual type with step arbor, partition work double skin for electrical lab safety h 4 feet, l 23 feet, supply and installation of electrical lab modular work bench / table for mounting electrical motors and generators and control panel box for electrician lab electrical ac and dc machines , modular work bench/ table for electrical lab, threephase ac main control and distribution panel board 36 l x 24 h x10 d, combination set of 1 panel board thyristor / igbt controlled a.c. motor drive vvvf control 3 phase, 2 hp and thyristor /igbt controlled d.c. motor drive 1 hp , combination set of 1 panel board single phase transformer core type air cooled 1 kva 240/415 v 50 hz and three phase transformer shell type oil cooled 3 kva 415/240 v 50 hz, combination set of 1 panel board d.c. compound generator 2.5 kw 220v coupled with 3phase squirrel cage induction motor 5hp 440v, combination set of 1 panel board d.c. shunt generator 2.5 kw 220v coupled with 3 phase squirrel cage induction motor 5hp 440v, combination set of 1 panel board 3-phase ac squirrel cage motor 5 hp 3-phase 415 v 50 hz and single phase series type motor 1 hp 240 v 50 hz, combination set of 1 panel board motor-generator set ac to dc squirrel cage induction motor 7.5 hp, 415v coupled with dc shunt generator 5 kw 440v , combination set of 1 panel board motor-generator set dc to ac shunt motor 5 hp 440v coupled with ac generator 3 phase 4 wire 3.5 kva 400/230 volts foot mounted, combination set of 1 panel board dc shunt motor 2.5 kw 220 v and dc compound motor 2.5 kw 220 v, combination set of 1 panel board dc series motor 2.5 kw 220 volts and single phase universal motor 240 v 50 hz 1 hp

State Government

CTN :42954604 Due date: 13 Dec, 202513 Dec, 2025 NA
Tender For supply of electrical and electronics enginerring lab equipments - symmetrical and unsymmetric al faults of transmission line , testing of hrc fuse aodmcb , overcurrent relay trainer , tbree phase air circuit breaker (acb) trainer , .differential relay trainer kit for transformer , generator protection relay trainer kit , dc servo position control trainer kit , ac servo position control trainer kit , stepper motoer , synchro transmitter receiver , ammetersmi type voltmeter mi type wattmeter single phaselthree phase three phase power factor meters automatic power factor controller low power factor wattmeter single phase lux meter digital/energy meter shunt multiplier current transformer potential transformer modelofmi mc, dynamomete rand induction itype meters lcrlq meter hand beld type soldering iron synchroscop e frequency clip-on meter electrical and electronics tools three phase squirrel cage induction motor (cut section model) 5hpthree phase ac slip ring induction motor trainer , dc shunt motor -alternator set , basic wiring tools , basic wiring tools , brushless dc motor trainer kit , dual power supply multimeter, lcr meter cathode ray, oscilloscope function generator, signal generator digitallc tester, analog ic tester smd soldering, equipment cables/con nectors, television set television set, projector maintenance kit, tools vacuum, cleaner/blower components, microwave test bench, klystron power supply, microwave test bench -x, vswr meter frequency meter, pin modulator dso dc regulated power, supply synchro transmitter and receiver trainer kit, servo motor on-off control kit,, temperature sensor pi controller kit,, temperature sensor po controller kit,, temperature sensor pid controller kit,, temperature sensor plc, digital multimeter routers, repeater hub, switch connecting cables and connectors network bridge, null modem cable, microcontroller, trainer kit, cro, stepper motor, 7-segment led, display, trainer board, trainer board, trainer board, microcontroller, board, sensors, digital multimeter, and micro-ammeters, dual channel cro, passive components, resistor, variable inductor, potentiometer, digital multimeter, true rms, multimeter, dual channel cro, dc regulated power, supply, scr, dc regulated power, supply, thyristor kit, resistive load,, resistive- inductive, load

State Government

CTN :42971884 Due date: 30 Dec, 202530 Dec, 2025 5.23 Crore
Tender For survey investigation design supply installation testing and commissioning of tank filling scheme head works consisting of construction of intake well with connecting pipe jack well cum pump house vertical turbine pumps coupled to motors pump house elec works necessaty valves delivery pipe manifold system electrical panel soft starter capacitors 11kv transformer 11 or 0.433 kv substation kv power line and 11kv terminal bay rising main pressure distribution for filling up of 5 nos of mi or zp tanks by lifting water from bhadra river near donabaghatta village of bhadravathi taluk including operation and maintainance for a period of 5 years after successful completion of work for donabaghatta tank filling scheme on turn key basis

State Government

CTN :42859019 Due date: 19 Dec, 202519 Dec, 2025 9.81 Lacs
Tender For aoh of electrical equipment and auxiliaries of sstpp unit-1 of 2x600mw, sstpp, mppgcl, khandwa. - generator, misc works in generator overhauling, h2 purging after unit shutdown & h2 refilling before of unit light up., transformers, general overhauling of ht transformers, generating transformer(work description as detailed intender schedule), station transformer (work description as detailed intender schedule), inter-connecting transformer (work description as detailed intender schedule), unit auxiliary transformer (work description as detailed intender schedule), neutral grounding panel ( gen., gt, st, uats) {(work description as detailed intender schedule)}, general overhauling of lt transformers, lt dry type transformers (work description as detailed intender schedule), lt oil filled transformers (work description as detailed intender schedule), switchyard, breaker, isolators ,earth switch, bay equipments (cleaning & terminal tightness), bus ducts (work description as detailed intender schedule), 21/ 15.75 kv gen bus duct, 11 kv uat/st bus duct, 6.6 kv uat/st bus duct, lt transformer bus duct, esp, ltmsb & acp buses , ec panels & heater work (as per scope of work), ltmsb & acp breakers (as per scope of work), ltmsb & acp modules(as per scope of work)eerm=80 , cerm=80, gdrm=8, fields= 80, vfd supply=4, lighting supply & etc. = 25(approx), ht switchgear (11 kv/ 6.6 kv), bus cleaning , tightness & complete inspection of all buses., breaker cleaning, tightness & operation checking, bop switchgears panel / local control panels / wall mounted panels and 415v lt swbd/ mcc/acdb/dcdb switchgear panel, bus cleaning , tightness & complete inspection of all buses. breaker cleaning, tightness & operation checking, power house lighting & power supply, cleaning , tightness & complete inspection of all lightning transformers & ldb, providing power supply as per site requirement & for other maintenance work of bmd,tmd etc., ht motors, servicing of ht motors, ht motor cooler (general inspection & cleaning), lt motors servicing, motors above 40 kw, motor 40 kw to 11 kw, motors 10 kw to 5.5 kw, motors 5 kw to 1.1 kw, motors 1 kw and below, esp lt motors 1 kw and below, lt motor overhauling, motors above 40 kw(machining), motor 40 kw to 11 kw, motors 10 kw to 5.5 kw, motors 5 kw to 1.1 kw, motors 1 kw and below, servicing of dc bus, cleaning/servicing of 220 v dcdb buses & modules, servicing of soot blowers, servicing of soot blower motor 1 kw & below, servicing of soot blower panel/modules
 Loading, Please wait...

Connect us via What's Up