Tender For supply, installation, commissioning of lab items on turnkey basis at government college,- digital thermometer, zoology-ph meter, compound mircoscope, dissecting microscope, water and soil testing kit, spectrophotomeyter 340-900, digital haemoglobinometer, thin chrometography kit, laclanche cell, app to study charging and discharging of a capacitor, apparatus for measurement of capacitance abd inductance using imoedance at different frequency, measurment of wavelength of hene laser using ruler with laser complete setup, stop watch digital, zener regulated powe supply, impedance and power factor of lcr circuit, series and parellelresonance circuit, diac and triac characterstics apparatus, newtons ring apparatus complete with travelling microscope power supply and sodium lamp, vernier calipers , inertia table, photo diode characterstics apparatus, dielectric constant apparatus, lees apparatus to ditermine the hear condutivity of bad conductors of different geometery, mosfet characteristics apparatus, apparatus to determine the value of fplanks constant complete with photocell light source set of filter and powe supply, apparatus to study specific resistance and energy gap of a semiconductor, solar cell characterstics apparstus, fet characterstics apparatus, apparatus to study response curve for lcr circuits and to determine the resonance frequency, chemical balance, paper chromatography testing kit, ph meter digital with electrodes, heating melting 7 lit, melting point apparatus digital, do meter digital, vaccum pump , potentiometer digital, electronic digital balance, magnetic stirrer with hot plate, kjedal digestion unit 6 test, spectrophotometer 340-900 nm, water soil testing kit digital, digital balance accuract (0.001-200grm), cod digestion apparatus, tlc kit, digital melting point apparatus, distillation apparatus single distillation capacity 3 lt, digital balance 0.001-200, slide reader, micro pipette fixed 1-5 ml, distillation apparatus singhle distillation capacity 5 lt, water double wall 12 holes statinless steel, heating melting with regulator cap 500 ml, incubator stainless steel, heating melting with regulator cap 1 lt, autoclave portable, thin layer chromtaography kit, vortex shaker, centerifuge machine 3500 rpm, water and soil testing kit, ph meter, hot air over stainless steel, autoclave vertical capacity 50 ltr , digital colony counter, dissecting microscope, compound microscope, binocular microscope, image projection system, laminar air flow horizontal, digital tds meter, tisue culture rack, soxhlet extraction unit 200ml borosilicate galss, rotary mircotome, uv transiluminator, uv single beam spectrophotometer
Tender For corrigendum : supply and installation of automaticchlorinator for sambalpur ph no 1 and paharpur ph no 1 under malda mechanical division, phe dte
Tender For corrigendum : supply and installation of automaticchlorinator to make two chlorination system at sahajalpur ph no 1 and jot basanta ph no 1 under malda mechanical division, phe dte
Tender For supply and installation of various laboratory equipments - automatic vertical autoclave, water bath, liquid nitrogen container (cryocane), digital ph meter, electrophoresis apparatus, gel documentation system, micropipettes, nano drop, double distillation water assembly, seed germinator, conductivity meter, shaker (rotary), microwave oven, hot plate, hot air oven, flame photometer, laboratory centrifuge, double door refrigerator, visible spectrophotometer, chlorophyll meter/spad meter, uv-vissible spectrophotometer, soxhlet unit for fat/oil estimation, leaf area meter, deep freezer, knapsack power sprayer, digital refracto meter, fruit crusher, grinding and mixing machine, digital fruit penetrometer, double ring infiltrometer, hydraulic conductivity meter, micro kjeldahl n digestion and distillation, compund binocular student microscope, stereo microscope vertical, bod incubator, incubator, laminar air flow bench horizontal size, automatic seed/grain counter, growth chamber, block digestion system, incubator cum hatcher, milk analyser (automatic), mineral mixture plant, digital electronic balance (0.1 gm- 6.0 kg), digital electronic balance (0.1mg-220g), refrigerator
Tender For purchase of blood bank equipment- apheresis machine (blood cell separator, ahg (coombs) gel card along with free placement of compatible semi-automated system ice. micro typing centrifuge, micro typing incubator, micro typing reader having lis interface capability double distillation water unit, die electric blood bag tube sealer and tabletop centrifuge machine
Tender For ebid for supply and installation of various laboratory equipments - automatic vertical autoclave , water bath , liquid nitrogen container (cryocane) , digital ph meter , electrophoresis apparatus , gel documentation system , micropipettes , nano drop , double distillation water assembly , seed germinator , conductivity meter , shaker (rotary) , microwave oven , hot plate , hot air oven , flame photometer , laboratory centrifuge , double door refrigerator , visible spectrophotometer , refrigerator , printer type: laser colour printer , a4 black and white laser jet printer , printer multi function colour with both side printing , computer (all in one) , computer i5 (desktop) , photo copy machine(mfp) , lcd digital 55" tv display hdr , 3d technology panel type screen resolution , camera (dslr) with zoom wide angle photo lens , smart led uhd panel/tv 65 inch , interactive panel (86 inch) , cut model of si engine (petrol) , cut model of ci engine (diesel) , cut model of tractor , display models of all types of harrows (one set) , working model of seed drill , models of different types of threshing drums (one set)
Tender For purchase of various apparatus/instruments required for department of chemistry, chaudhary ranbir singh university, jind - stirrer the stirrer should be made up of ceramic coated aluminium alloy top with digital speed and temperature control. the stirring speed should be 50-1500 rpm or better. the stirrer should be operational up to a temperature range of 300oc with an accuracy of 1.0oc and ip 42 protection class. the input power should be 600 w or above. the stirrer should be supplied with hemispheric bowl (100 ml= 1 no; 250 ml= 1 no) to replace oil baths and mantles in order to perform clean and safe analysis with round bottom flasks., electronic balance the electronic balance should have a maximum weighing capacity of 200 g or more with a resolution and repeatability of 0.1 mg, and a response time of 5 sec or better. the system should have automatic internal calibration with touch screen display. the system should have internal database capacity of 2500 or more with multiuser password protection feature. , vacuum pumpthe pump should be operational at a maximum power of 65 w or more with a max. vaccum of 99 mbar or more. the pump should be fitted with vacuum and filter cartridge., hot air oventhe inner chamber should be made of stainless steel and the outer chamber should be m.s powder coated. the maximum capacity of the oven should be 100 ml or more. the operational temperature should be between ambient to 250 oc or more with a temperature accuracy of 1o c. pid based digital temperature control., double distillation unitthe unit should be pyrogen free with a distillation water output capacity of 1.5 l/h. the minimum cooling water requirement should be 1lt/min. auto-power cut facility in case of halted supply of water., circulating oil baththe oil bath should be made up of stainless steel with 4 digit 7 segment led display for temperature and time. the bath should have s.s perforated tray for holding flasks. the bath should have a capacity to accommodate flask of 1l. the working temperature range should be +5 to 240 oc (0.1 oc increment) with a temperature stability of 1oc., water baththe water bath should have a capacity of 20 l within built water level sensor. the bath should be made up of stainless steel and supplied with 8 concentric rings. the bath should have digital temperature control with pt100 sensor. the system should have stirring capability with ptfe magnetic bars. , ph conductivity meter operational between a ph range of -2 to 16.00 with a resolution of 0.01 ph and an accuracy of 0.02 ph. 5 points calibration. the ec range should be in between 0.00 to 29.99 s/cm, uv cabinet operational at two uv wavelengths (254 and 365 nm). the cabinet should also be equipped with one visible light. the external body should be coated with ms powder/epoxy., flame photometerapplication: the flame photometer is used for qualitative and quantitative determination of several cations, especially for metals that are easily excited to higher energy levels at flametemperature. these metals include na+, k+, ca2+, ba2+ and li2+.specification requirementmeasuring range na+: 0 to 99.9 ppm k+:0 to 99.9 ppm ca2+ :0-99.9 ppmli2+: 0 to 99.99 ppmsensitivity na+= 0.1 ppmk+ = 0.1 ppmspecificity less than 0.5% interference when concentrations are equal to test sample concentrationsgas control-adjustable with knobsignition system-auto ignition systemflame failure-auto detectiongas cut off-automaticreproducibility-less than 1% coefficient of variation for 20 consecutive samplesusing 10 ppm na set as maximum standardlinearity-less than 1%display led, 12.5 mm (1/2")fuel supply-high-grade propane/butane mixture regulated at approximately30 psiair supply-6 l/min at 12 psi; oil and moisture freerecorder-output 0.05 to 5 v (switchable)operating manuals, service manuals, other manuals should provide user, technical and maintenance manuals in english language list of equipment and procedures required for local calibration and routine maintenance service and