Tender For supply of 5 kva, 25kv/240v , 50 hz single phase oil filled l.t. supply auxiliarytransformer for railway ac traction system as per rdso spec. no.eti/psi/15 (08/2003) or latest. [ warranty period: 30 months after the date of delivery ] ]
Tender For work of transformer painting with degreasing and de-rusting of all the external surface of transformers i.e. main tank + radiators + conservator + accessories + fittings of various voltage class and capacity under vapi amd division.
Tender For work of transformer painting with degreasing and de-rusting of all the external surface of transformers i.e. main tank + radiators + conservator + accessories + fittings of various voltage class and capacity under ichhapore amd division.
Tender For work of transformer painting with degreasing and de-rusting of all the external surface of transformers i.e. main tank + radiators + conservator + accessories + fittings of various voltage class and capacity under vav/vyara amd division.
Tender For auction sale of 3.15 mva bgp failed ptr scrap,10 kva copper wound transformer (without oil)-08 nos,11, 33 kv ct/pt units etc,iron steel scrap (field return), barberd wire scrap,fiber scrap, scrape of energy meter mechanical/ electronic/static etc,transformer leminations used,copper winding wire/coils of transformer and mo,tank empty old of transformers /ocb/vcb/equipments,battery scrap (lot ctrl)
Tender For providing of custom bid for services - custom bid for services - deputation of oem m/s bhel expert for internal inspection of 20mva,16,5 kv/6,9kv unit auxiliarytransformer no 5b( sl no 2017576) at mtps,dvc,bankura(wb)
Tender For corrigendum : supply of oil level indicator for generator transformer , oil level indicator for unit auxiliarytransformer , oil level indicator for start up transformer
Tender For distribution transformer of rating 500 kva, 11kv/415v-240v, 3-phase, 50hz, outdoor type, plinth mounted, on load type tap changer for variation of hv voltage from +5% to -15% in steps of 2.5%, energy efficiency level 3 or better, oil immersed, non-sealed type (transformer tank body and cover are bolted), copper wound, primary winding in delta and secondary winding in star (vector symbol- dyn11), onan cooled transformer, confirming to is 1180 (part 1): 2014 with amendment nos. 1,2,3,4 or latest, and supplied with all standard fittings mentioned in clause 20.1 of is 1180 (part 1) latest with condition that drain-cum-sampling valve will be applicable for all capacity of transformers. oil temperature indicator & winding temperature indicators will be provided as per clause 20.2 of is 1180 (part 1). terminal arrangement: the transformers shall be fitted on high voltage and low voltage sides with outdoor type bushings appropriate voltage and current ratings. the high voltage bushings (3 nos.) shall confirm to is/iec 60137. the low voltage bushings (4 nos.) shall confirm to is 7421. suitable cable-end box along with cable entry hole glands is tobe provided at l.t. side. following has to be submitted by supplier along with supply of material: (i) type test report of transformer having same rating, make (& model if any) and design from nabl accredited lab as per is 1180 (part 1) latest. (ii) routine test certificates as per is: 1180(part 1) latest. (iii) special test certificates as per clause 21.4 sl. no. (a), (c), (d), (e) of is: 1180 (part 1) latest. bee star rating:- 3 or above (firm shall submit a valid bee certificate for the offered product with desired bee star rating). [ warranty period: 30 months after the date of delivery ] ]