Web Analytics Made Easy - StatCounter

Auxiliary Warning System Tenders

Get complete information related to latest Auxiliary Warning System Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Auxiliary Warning System Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Auxiliary Warning System Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :39076328 Due date: 08 Feb, 202508 Feb, 2025 NA
Tender For purchase of equipment - purchase of equipment, 1. general description single stand-alone system should dispense all three types of water (type i, type ii, type iii) from a tap water feed system should be compact requiring less space. system should be supplied with 5 micron, 1 micron and activated carbon pre filter with boost pump to remove particulates in water. system should have an internal storage tank of 7 litres (or better) with complete recirculation. the system should incorporate graphic colour lcd display to provide information on system status and performance parameters such as conductivity, resistivity, temperature and storage volume and also alarm notification for troubleshooting. system should have dual wavelength uv lamp. system should have a completer recirculation facility which can able to re-circulate water through purification components to maintain high purity. the system should have a water quality sensor at the dispense point to ensure water quality. system should have volumetric dispensing options from 50 ml to 7 litres. system should have data capture using usb to keep track of water quality and software upgrades. type iii water production rate 10 litres per hour (or better).2. ultrapure (type i) water specifications resistivity: 18.2 m .cm @ 25 c dispense flow rate: up to 1.2 l/min toc: 5 ppb bacterial tvc: 0.1 cfu/ml endotoxin: 0.001 eu/ml rnases: 1 pg/ml dnases: 5 pg/ml ph: effectively neutral particulates: 0.2 m filtration3. feed water specifications water source: portable water source conductivity: 2000 s/ hardness: 350 ppm as caco free chlorine: 0.05 ppm cl chloramine: 0.02 ppm cl total chlorine: 0.05 ppm cl silica: 30 ppm sio carbon dioxide (co2): 30 ppm fouling index: 10 iron/manganese: 0.5 ppm fe/mn toc (total organic carbon): 2ppm4. warranty one + optional two years5. general terms and conditions the installation should be done at free of cost. hands-on training must be provided on operation, maintenance and troubleshooting to two-three persons at the site of installation. additional features and features in the quoted equipment which are better than those in the indent may be clearly explained.

State Government

CTN :39102828 Due date: 04 Feb, 202504 Feb, 2025 96.39 Lacs
Tender For and operation of electrical sub-station, d.g. sets, fire alarm system, wet riser an sprinkler system, drinking water supply pump set, passenger lift and escalators installed at extension block tis hazari court.)

CTN :39112102 Due date: 04 Feb, 202504 Feb, 2025 5.37 Lacs
Tender For 1. construction of office building for central administrative tribunal (cat), lucknow bench, including internal electrical installation, fire fighting system, fire alarm, vrv/vrf system, epabx system, dg set, sub station, lift, water supply and horticulture work at gomti nagar, lucknow (up). 2. renovation and improvement of 11 nos. custom department quarters including iei and fans etc. at nehru enclave, vishwas khand, gomti nagar, lucknow. (up). (sh. providing services for computer operator, peon/dak runner etc).

CTN :39117111 Due date: 05 Feb, 202505 Feb, 2025 23.49 Lacs
Tender For annual maintenance and operation of addressable fire alarm system bms system and water based fire fighting system including maintenance of electrical installation and fans street lighting repair maintenance of pump set installed at csd and w bhopal for the year 2023-24 sh :- replacement of existing worm out defective electrical panel supplying and laying of lt cables and supplying and installation of street lights in csd and w campus and other allied electrical worksubwork/packages:replacement of existing worm out defective electrical panel at csd&w bhopal

CTN :39089567 Due date: 31 Jan, 202531 Jan, 2025 13.77 Lacs
Tender For 1) maintenance of electrical installation & repair maintenance of passenger lift, dg sets, outdoor type sub-station, at income tax annexe and main building at vani vihar, bhubaneswar dg 2024-25. 2) annual maintenance contract of passenger lifts, dg sets, outdoor type sub-station i/c repair maintenance of fire alarm & fire fighting system at income tax annexe and main building at vanivihar, bhubaneswar dg 2024-25. 3) maintenance of electrical installation & fans i/c repair maintenance of water supply pump sets, street lights etc at cr colony at vanivihar, bhubaneswar. sh-replacement of light fittings, wiring, fans, switch/sockets, street lights, pump etc.

Central Government / Public Sector

CTN :39073038 Due date: 21 Feb, 202521 Feb, 2025 NA
Tender For supply of high-performance cooling pac unit, 08 tr or higher , high- performance cooling pac unit, 03 tr or higher , air purification system , acs-access control system , ip based cctv surveillance system , fire detection and alarm system-fdas , clean agent-based fire suppression system , vesda-very early smoke detection apparatus system , water leak detection system -wlds , rodent repellent system , building management system , civil or mechanical or electrical or cabling work , quote for 04 years post warranty comprehensive amc of supplied high- performance cooling pac units -08 tr or higher , quote for 04 years post warranty comprehensive amc of supplied high-performance cooling pac units -03 tr or higher , quote for 04 years post warranty comprehensive amc of supplied 1000 cfm air purification system. , quote for 04 years post warranty comprehensive amc of supplied acs- access control system and its components. , quote for 04 years post warranty comprehensive amc of supplied ip based cctv surveillance system and its components. , quote for 04 years post warranty comprehensive amc of supplied fire detection and alarm system and its components. , quote for 04 years post warranty comprehensive amc of supplied clean agent-based fire suppression system and its components. , quote for 04 years post warranty comprehensive amc of supplied vesda system its components. , quote for 04 years post warranty comprehensive amc of supplied water leak detection system its components. , quote for 04 years post warranty comprehensive amc of supplied rodent repellent system and its components. , quote for 04 years post warranty comprehensive amc of supplied building management system its components. , quote for 05 years comprehensive amc of data centre electrical system

CTN :38969081 Due date: 30 Jan, 202530 Jan, 2025 8.09 Lacs
Tender For various wqms activity 2024-25 (water quality monitoring survey). supply of laboratory equipement and chemical etc. and all other works contingent thereto. - bact. incubator:- nsw, ambassdor, optics technology, impact size 18x24x18.precise sterilization, incubating and drying in one unit. better mineral/ glass wool blanker insulation keeps the surface of the instrument from being burnt.silent hot air blower unique design of air circulation for uniform air movement. unique design of ventilation keeps the surface of the instruments from veing burnt. polish 304 grade s. steel interior corrosion resistant long life operation having adjustable shelves to make more space for different height. kanthal a-1, super quality coil shaped heaters duly embedded / wounded on the sides and bottom for better accuracy . full feature with touch screen controller temperature controller. a. hmi display with feather screen touch digital temperature controller b. continuous display of temperature, time, day and date door open alarm c. password protected operations. d. data transfer port: usb port technical specification:- temperature range : ambient to 70 c temperature stability : 0.5 c control panel : with mains and load indicator, mcb alarm , material : gi/ms with powder coated, inner : stainless steel 304, digital setting : 0.1 c digital resolution : 0.1 c safety function : temp. over shoot high and low temp. alarm 5 d c , mcb provided insulation: mineral wool front door : mineral wool insulated door with glass window. hardware:- lock and handle material zinc, base finish: spc, handle finish: black pc b3with key. hinges material zinc, pin material : ss 304 grade, finish stpc, opening angle : 180 deg power consumption: 220/230v ac supply 10% hz duty cycle : continuous, air conditioner 1.5 ton split, autoclave:- nsw,ambassdor, impact digital cap:- 78 liters heater:- 04kw size:- 400x600mm outer ss sheet chamber inner s.s. 304 unique desingn of radial locking for minimum steam loss, assure accurate steam generation / sterilization. s. steel 304 grade argon welded cylindrical inner tank / vessel having s. steel tabular immersion heater for steam generation. lid is made of thick mild steel plain lined with s. steel sheet for double protection optional : all s. steel thick lined lid/ s.s. ring 304 grade (all outer s. s. outer body-304 grade steel on customer request). fitted with painted mild steel ring and radial locking duly chrome plated. paddle lifting device is also provided. lid is having built in safety valve, release valve pressure gauge, water level / indicator. supplied with s. steel cylindrical basket. pressure range is adjustable from 05 to 20 psi 3 psi or better inner and outer wall both made of stainless steel. gasket is made from imported silicon rubber. fitted with microprocessor based fully automatic fuzzy logic control system with timer buzzer (auto time control). the unit is also fitted with low-water level cut-off as a standard feature. fitted with automatic purging and exhaust valve, beakers 1000ml (borosil), bottle brush, brown paper sheet, colour standard (100ml), cotton (500gm), dessicator (big size), borosil, durum tubes (100 in each pkt.), evaparating dish (12 nos) make borosil 3180072 evaporating, flat bottom with pour out dish ( approx o.d x height : 80x45 mm), macconkey broth (hi-media) 500gm, refrigrator temperature 0 to 20 c vertical shelves, atleast 6-shelves for storage of sample, inbuilt temperature controller, castor wheels for easy mobility, heavy duty wheels, toughend glass refrigrator with temp controll visi cooler with temperature indicator with nabl calibration 550 litres manual defrost system complete fridge dimensions - 64.00 x 72.00 x 205.00 cms reciprocating compressor 12 months warranty storage, silica gel grannules , 500 gm qualigens, spactula (steel), test tube basket, test tube stands (alumimium), test tubes (15x150mm), test tubes (18x150mm), turbidity standard (100ml)

CTN :39025675 Due date: 11 Feb, 202511 Feb, 2025 55.12 Crore
Tender For upgradation and modification of existing sports facilities and construction of indoor multipurpose building for sports facilities at iit(ism) dhanbad. sh: construction of student activity centre-2 (g plus 3), refurbishment of basketball & tennis court and construction of red soil volleyball court & seating stand with tensile fabric roofing, i/c internal water supply, sanitary installation, drainage, sewerage, u.g. tank, storm water drains, roads & paths, internal e.i. & fans, wet riser and sprinkler system, fire alarm system, ups, facade lighting, signages, street lighting, ground lighting, lifts, horticulture & landscaping and other development work & bulk services (civil & electrical) (package-ii)

State Government

CTN :39049502 Due date: 13 Feb, 202513 Feb, 2025 40.00 Lacs
Tender For supply of various items for the dhr project entitled molecular biology applications research and diagnostic techniques - laboratory items, pc based true double beam uv-visible spectrophotometerspecification:1. optical system: czerny-turner mounting, single monochromator, double- beam system, 1,300 lines/mm, 240 nm blazed holographic grating 2. light source: deuterium lamp and tungsten-halogen lamp 3. detector: r-928 photomultiplier tube 4. wavelength range: 185 to 900 nm or higher 5. wavelength accuracy: 0.1 nm (656.1 nm) 6. wavelength repeatability: 0.05 nm 7. spectral bandwidth: 0.1, 0.2, 0.5, 1, 2, 5 nm in steps 8. resolution: 0.1 nm 9. stray light: max. 0.005 %t (220 nm nai) 10. mode: abs, %t, %r, 11. photometric range: -5 to 5 abs12. noise level: 0.00003 abs rms (500 nm) 13. wavelength slew rate: 14000 nm/min 14. wavelength scan rate: 4000 to 0.5 nm/min 15. below items must be supplied along with the main instrument:a) one pair of cuvettes, 10 mm path length, 3.5 ml volumeb) integrating sphere attachmentwavelength range: 220 nm to 850 nm or betteri) samples like powder, solid, colloidal sample, thin film etc are measured by using thisaccessoryii) minimum inner diameter of integrating sphere: 60 mmc) branded i5 pc with original os- 1 no, class ii, type a2 bio-safety cabinetspecification: 1. the bio-safety cabinets should be 4 feet width with front window must be a 10 sash opening and steel with smart coat interior 2. the bio safety cabinet must include dc motors. 3. the motor must automatically adjust the airflow speed without the use of a damper to ensure continuous safe working conditions, even without maintenance adjustments. 4. cabinet must use a pressure sensor (rather than anemometer) to detect pressure drop across the supply filter, rather than in just one point across the down flow. 5. the cabinet should display the inflow and down flow air velocities and must incorporate an led indicator, visual & audible alarm to indicate excessive hepa filters loading, blower failure, airflow speed failure, incorrect window position. 6. the front of the cabinet must be angled 10 to help minimize glare. 7. the cabinet noise level must be less than 65 db(a) for a 4-foot cabinet. 8. cabinet with lights on and fan at operating speed should consume less than 400 watts or less 9. the cabinet must automatically reduce fan/blower motor speed to 30% when the front window sash is in closed position to ensure reduced energy consumption when the cabinet is not is use. 10. uv light must be programmable to allow for specific exposure times from 0 to 24 hours. 11. the cabinet should have provision to fit taps for vacuum, water and non-combustible gas. 12. the bio safety cabinet should be nsf certified with listing on nsf website. 13. the bio safety cabinet should incorporate hepa filter of the class h 14 en 1822 or better and having minimum efficiency of 99.995% at 0.3 m particle size. 14. ventilation system exhaust and inflow air volume approx 300-350 cfm 15. audible and visual alarms for hepa filter failure, blower failure, airflow speed failure, incorrect window position. 16. the cabinet should be provided with fixed / adjustable height stand, uv light and one set of detachable arms rest and one / two electrical outlet. 17. the drain pan of the bsc should be made of stainless steel. the drain pan should not be painted, or power coated. 18. cabinet should be ce certified and declaration of moc should be provided. 19. port provision for clean and safe routing for vacuum tubing and cables throughthe side of the bsc for improved organization and work efficiency., vacuum ovenspecification: 1.volume(l): 60-802.temperature range ( c): rt+5-2503.temperature resolution ( c): 0.1(at 100 c)4.temperature variation ( c): (at100 c)5.heating power (w): 21006.vaccum range 0 ~ 1 atm7.timer: 1min ~ 99hr59min8.vaccum connector (mm): 109.venting connector (mm): 1010.inner size (mm): 400x400x40011.dimension (mm): 625x585x710, constant temperature incubators

CTN :39052717 Due date: 05 Feb, 202505 Feb, 2025 20.69 Crore
Tender For providing additional infrastructure in 10 acres land (hostel block) at idbi centre for excellence in banking and finance (icbf), campus at gachibowli, hyderabad. sh: construction of vip cum hostel block i/c internal water supply & sanitary installations, drainage, bulk services and e&m works consist of internal electrical installations, air conditioners, 16 passenger lifts, fire fighting and fire alarm system, lan & networking system, lan & ip based epbax system, cctv cameras, led tv, 100 kwp solar plant, kitchen ventilation system.
 Loading, Please wait...

Connect us via What's Up