Tender For supply of still compact digital camera.specifications(1) effective pixels (mega pixels) -24(2) lens mounting-detachable. (3) optical zoom-31x to 35x,(4) maximum recording resolution (pixels) -hd (1280x720)(5) video file format-mov, avi, mp4(6) flash-built-in(7) connectivity interface-bluetooth, usb(8) control-remote, app(9) supported operating system for app-ios, android, windows(10) memory card expandable up to (gb)-256(11) power source-rechargeable battery(12) battery capacity(mah)-4500. make:- sony/ canon/ panasonic/ kodak/nikon or similar .
Tender For purchase of sports exercise physiology lab equipments - cardiopulmonary exercise testing system (including treadmill & cycle ergometer) (2 years warranty)(pac), portable telemetric metabolic analyzer for field and laboratory use.metabolic analyzer portable telemetric system for metabolic analysis should have the following specifications:designlatest generation, single body - weather and dust proof to suit our requirement of tough testing conditions. it should operate in standalone, holter and direct connection to pc modes.weight on subjectless than 1 kg including battery and ergonomically designed multi-size adjustable harnesstesting capabilitypulmonary gas exchange (vo2, vco2), vo2 max, sub-max vo2, thresholds (at, rcp), heartrate with hr belt, resting energy expenditure (ree, rmr), indirect calorimetry w/ face mask, substrates analysis (rq, %fat, %pro, %cho)analysis method breath by breathmotion sensorsinbuilt gps, altimeter, accelerometer (3d + 8g range), gyroscope (3d + 2000 o/s range) andmagnetometer/compass (3d + 1000 t range)wireless connectivitywireless data transmission: bluetooth 2.1 + edr class ii (range >900 meters line-of-sight)connectivityusb, audio, heart rate (aux), wireless device interface (bluetooth for integration with compatible optional peripherals like spo2, ecg etc.)data storagestorage: 512 mb flash > 2,000,000 breathsadditional: sd-hc card 32gb/fat32 - internal slot user accessibledisplay lcd: 3.5 lcd transflective colour - high visibility with led-backlit tfttouch-screen: resistive technology, that allows gloves and wet fingersanalysersoxygen: gfc 0-25% range, lifespan approximately 12 months (very easily user replaceable) response time 120 mscarbon-dioxide: digital ndir 0-10% range, response time 100 msbarometer: range -600 to +5500mflowmeter: bi-directional digital turbine ventilation range 0 to 300 l/min powerbattery: rechargeable li-ion smart battery w/ lcd charge status indicator. 2 packs backupbattery: embedded to allow main battery replacement during testing without loss of datamain: 100-240v ac/dc adapter, for direct/main power supply and battery charging. essential accessories / consumablesthe system should be supplied with a compatible treadmill and ergo cycle as per specs below. list of standard items supplied and details of consumables including o2 sensor with their life span should be provided. a compatible laptop pc, colour deskjet printer, 3 litre calibration syringe & calibration gas mixture cylinder with regulator should be supplied with the systemquality assurancemust have european ce, us fda and iso certifications. treadmill running machine with user terminal (display & keyboard) stand- alone and remote control with cpet via rs232 running surface: l:170 cm (minimum), w: 65 cm (minimum) maximum possible load: 300 kg (660 lbs) speed range: 0-25 km/h elevation: 0 to 28% reverse belt rotation motor system 3.3 kw, single phase ac motor, maintenance free and brushless power transmission: frequency inverter, poly v - belt, very quiet operation safety arch should be provided with harness of 5(five) different sizes (small to large) safety system: emergency-off safety stop switch (safety lanyard with actuator, pull cord and clip); potential equalization bolt; transformer for potential-isolation from the mains ambient condition: temperature: +10 to +40 degrees c, humidity 30 to 70% display: touch screen display heartrate monitoring: wireless transmitter; the treadmill should be able to interface with well-known compatible metabolic gas analyzer as per standard and custom exercise protocols different programs para control software for pc must have ce certificationergo cycle functional design and excellent stability, load up to 160kg. easy to use saddle, handle bar and pedals speed independent and dependent power control handle bars are easy to change to suit different tests, rotatable by 360 degrees. mechanical/motor-assisted seat adjustment easy to control and calibrate. can be co
Tender For corrigendum : technical specification point wise dbs implant & accessories - dbs rechargeable with directional lead with25yr battery life & image guided programming integrated inside clinician programmer with micc multiple independent current control technology with zero volt technology,bluetooth connectivity with clinician and patient programmers, usfda & ce approved kit contents: rechargeable pulse generator-1 , directional lead kit -2 , extension kit -2 , burr hole locking kit -2 , tunneling tool -1 , patient remote control kit -1, patient charging kit -1 , dbs rechargeable with non directional lead with 25yr battery life & image guided programming integrated inside clinician programmer micc multiple independent current control technology with zero volt technology,bluetooth connectivity with clinician and patient programmers. have 8 contact non-directional lead kit with array span of 15.5mm for maximum coverage, usfda & ce approved kit contents:rechargeable pulse generator -1, non-directional lead kit -2, extension kit -2, burr hole locking kit -2, tunneling tool -1, patient remote control kit -1, patient charging kit -1, dbs non rechargeable with directional lead with image guided programming integrated inside clinician programmer micc multiple independent current control technology &bluetooth connectivity with clinician and patient programmers,usfda & ce approved kit contents: non-rechargeable pulse generator -1 , directional lead kit -2 , extension kit -2, burr hole locking kit -2 , tunneling tool -1 , patient remote control kit -1,), dbs non rechargeable with non-directional lead with image guided programming integrated inside clinician programmermicc multiple independent current control technology withbluetooth connectivity with clinician and patient programmers. should have 8 contact non-directional lead kit with array span of 15.5mm for maximum coverage,usfda & ce approved kit contents: non-rechargeable pulse generator -1, non-directional lead 1), dbs implant kit with non-rechargeable, 3t mri compatible and sensing enabled ipg and directional leads.the implanted pulse generator (dbs neurostimulator- ipg) should have a minimum service life of 5-7 years and there should not be a need to recharge it periodically.ipg should have the capability for group programming and ability to store the programming data in ipg itself and retrieve from ipg.the system should be able to sense local field potentials (lfps) from brain targets and this data should be accessible through the physician programmer. the leads should be able to stimulate in specific directions, in addition to the ability to stimulate circumferentially. markers on leads should facilitate directional programming even if lead rotates. the leads should also be able to sense lfps.burrhole kit should be there for securing lead in place. microelectrodes for intra op stimulation and recording should be there.the extension connecting the lead and ipg should be flexiblethere should be a tunneller to place the extension wire and the tunneller should be metallic and firm to enable smooth tunnelling.the system should have approval for conditional full-body 1.5t & 3t mri compatibility.patient programmer, enabling the patient to see and if needed, modify the stimulation under guidance, should be available. patients should be able to mark dyskinesia, tremor etc. using the programmer., dbs implant kit with rechargeable, 1.5t & 3t mri compatible and sensing enabled ipg and directional leads.the implantable pulse generator (dbs neurostimulator- ipg) should have a service life of 15+ years if regularly recharged by the patient at specified intervals.ipg should have the capability for group programming and ability to store the programming data in ipg itself and retrieve from ipg.the system should be able to sense local field potentials (lfps) from brain targets and this data should be accessible through the physician programmer. the system shou