Tender For supply of : set of magnetic test spray for magnetic particle testing (mpt), each set consist of two items : (1) white contrast coat (in 400 ml aerosol can pack)-01 number (2) magnetic black ink oil base (in 400 ml aerosol can pack)-03 numbers, in one set. (ratio 1:3) numbers. accepted offer : 1 set consist of pmc ins tacheck snowite contrast coat msl-61b 400ml/300gm 1 can and pmc instacheck magnetic ink ml-72b oil b ase black colour 400ml/300gm 3 can per set total 4 sets in 525 ml capacity aerosol can meets the require ment of confirming to rdso specification no. m and c/ndt/109/2007 (rev-2) [ warranty period: 30 mon ths after the date of delivery ]
Tender For procurement of spares for il-78 aircraft - fixture to deliver the video endoscope to inspection zone, fixture, guide tube, delivery device, template, vibration acceleration indicator, unit set, special tool for dome removal, device for air wheels tire tube filling, eddy current transducer, test equipment, branch standard specimen for eddy current inspection, unit to flush the engine gas flow duct (complete with metal hoses), detector, washer, locking, washer, locking, washer, screw, chisel, plier, round nosed, non destructive testing standard working specimen, puller oil pump gear, fixture oil pump installation, fixture for ultrasonic inspection, pliers, ultrasonic flaw detector, seal
Tender For rfp for supply of various electrical material at i/a sez-ii, pithampur, distt. dhar (m.p.) - supply installation testing and commissioning of 132kv ct having ratio of 400/1-1-1 a., supply of 33kv ct having ratio of 400/1-1-1 a. as per standart of mpptcl top bottam standard., supply installation testing and commissioning of 220/132/33kv s/s sec.-3 support abt, 3phase 4wire meter, class 0.2s make secure., supply installation testing and commissioning of 200 kva conventional 5star distribution transformer., supply installation testing and commissioning of 18 unit for 12mvar capacitor bank at 132kv s/s, supply installation testing and commissioning of 10kva/48v invertor cum battery for custom office use at niryat bhavan sez-ii., supply installation testing and commissioning of 110volt. 300ah make hertz electronics at 132kv s/s sez-ii., supply installation testing and commissioning of 48 volt. 200ah make hertz electronics at 132kv s/s sez-ii., supply copper control cable 12 core. 2.5 sq.mm. (armoured), supply ct clamp sutable for 11 kv ct, supply 33 kv ttb, supply 11 kv ttb, supply 33 kv vcb, outdoor porcelain clad type with complete structure and accessories including existing control pannel wiring for feeder protection excluding ct & pannel, supply33 kv ct 1200/1 amp as per standart of mpptcl top bottam standard., supply33 kv ct outdoor oil immersed type 400-200/5-5 amp, supply secure meter 0.2 clss accuracy premier series 300 3phase 4 wire, supply 33 kv control & relay panel with over current and earth fault static relay for transformer & feeder protection (avana), sitc 33 kv vcb, outdoor porcelain clad type with complete structure and accessories ct & breaker excluding ct & pannel, supply 11 kv ct outdoor oil immersed type 300-150/5-5 amp, supply handling & installation of 33 kv feeder/xmer vcb complete on foundation & tightening/ alingment of of vcb. with old vcb dismentling, supply handling & installation of control pannel , including stand of suitable size for 33/11kv feeder and transformer control, supply installation testing and comissioning 33kv isolator 800amp. copper contactors., supply dlms compliant single phase electronic meter with data downloading facility & box 5-30 amps secure, genus., supply three phase whole current smart meter with box 10-100 a with data downloading facility & box, supply testing and commissionnng of vcb and control pannel, supply sheet metal meter box suitable for h.t. static travector meters with ttb, supply copper control cable 2 core. 2.5 sq.mm. (armoured), supply copper control cable 4 core. 2.5 sq.mm. (armoured), supply copper control cable 8 core. 2.5 sq.mm. (armoured), supplycopper control cable 10 core. 2.5 sq.mm. (armoured), supply copper control cable 12 core. 2.5 sq.mm. (armoured), supply aluminium cable 2 core. 4 sq.mm. (unarmoured), 2 x c al 10 sqmm cable, 2 x c al 16 sqmm cable, 1 x c copper 2.5 sqmm wire, 100 amps mcb, supply junction box for hymast and street lights with inbuild 100 amps mcb for main supply & 63 amps for outgoing supply for hymast and street lights, supply 16 sqmm cable al 4 x c (four-core) (non-abc) having cloth covering suitable for hymast connection, supply 25 sqmm cable al 4 x c ( four core) armoured cable (non abc) for providing 3 phase supply to hymast, supply pvc insulation tape, supply 4 point connectors for hymast, supply 25 sqmm lugs for hymast cables, supply 2.5 sqmm cu flexible wire, supply pvc tape 2*30(box), supply m seal, supply ferrule (r,y,b,n and 0 to 9) each 1 set, supply pvc insulated pvc sheathed 3.5 core 35 sqmm aluminium conductor 1100 volts, supply pvc insulated 2 core 10 sqmm cable
Tender For corrigendum : special repair for renewel of e/m items and plant/ machinery held in charge of age (e/m) rnd agra cantt under ge (i) rnd delhi - supply , installatation , testing and commissioning of diesel driven generating set to give an out put of 500 kva, 415v ac supply 3 phase, 50 hz, 4 wire radiator mounted on common base plate complete with fuel tank, vibration damper and other accessories with fuel tank viberation damper and other accessories with acoustic enclouser as per latest cpcb-iv norms and amf panel including pcc foundation work as per oem reccommandation and taking out the old dg set from the location and deposited to mes store yard complete all as specified and directed, interanally comprising of following :-(a) diesel driven engine :- developing a net output suitable matched to give a net rated output of minimum 604 hp/suitable to drive 500 kva alternator, at 0.8 power factor 415 volts. the engine should be capable of delivering the required output at 1500 rpm, water cooled, self start, with a provision of 10% overload for one hour in every 12 hours with the following accessories and all as specified.(i) fly wheel to suit flexible coupling and fly wheel housing.(ii) air cleaner complete as per manufacturer specification. (iii) fuel injection pump. (iv) flexible coupling with guard, nuts and bolts.(v) fuel filter with mounting. (vi) oil filter with mounting.(vii) starter motor as per manufactures design.(viii) exhaust, silencer industrial type with exhaust pipe suitable length.(ix) batteries 12 volts 2x180 ah maintenance free batteries with copper lead, terminals etc.(x) instrument panel complete with microprocessor based controller comprising shut down valve indication, lcd hour counter indication, rpm indication , led lamps for fail to start, over speed /under speed . low lub oil pressure, high engine coolant temperature. gaugae.(xi) dynamo/alternator suitable rating., (b) alternator :-the above engine will be coupled through flexible coupling on an indigenous alternator mounted on a strong steel fabricated common base frame suitable for mounting in an acoustic enclousre. the alternator will be 3 phase 50 hz 1500 rpm self regulating self exciting type and have class h insulation of stator and rotor windings and generate 500 kva output at .8 power factor 4 wire 415 volts ac supply under ntp condition with a provision of 10% overload for 1 hour in every 12 hrs running. the alternator would be screen protected and fitted with shield ball/roller bearing, automatic voltage regulator.(c) control panel :- s&f amf (automatic on mains failure) control panel cpri approved outdoor ype kiosk water, dust and vermin proof and fabricated out of 3.15 mm thick crca sheet and 50mm x 50mm x 6mm angle iron powder coated suitable for 415 volts 3 phase 50 hz ac supply with and incl the following :-(i) mccb of suitable capacity(ii) necessary relays, times and power contractors of suitable rating/capacity for auto on-off the dg set and changeover of the load in case of power failure.(iii) digital mulfifunctional meter for phase wise reading of amps, voltage kwh and frequency -01(iv) internal wriring with single core solid copper conductor cable of appropriae gauge incl mumbering ferrules and control fuses.(v) earthing terminals 02 nos(vi) auto/manual start switch to by pass auto start.(vii) battery charging system suitable for charging for charging the battery provided with the dg set incl boost/stickle switch and system, dc voltmeter digital type., (d) fuel tank :- one no built in sheet metal steel tank mounted inside the acoustic encloser and of adequate capacitynot less than 740 ltr with inlet and outlet connection including the following :-(i) level indicator with float and gauge.(ii) fuel piping for fuel supply to engine and over flow to tank(iii) fuel strainer(e) acoustic enclosure :- enclousre be designed for reducing the sound level up to 75+/ 5db (average) as per is 8528 part 10 and as per approved cpcb morms. the acous
Tender For supply of machines and laboratory equipment?s for electronics engineering - 8051 microcontroller trainer , lcd 16x4 alphanumeric display , 4x4 matrix deypad , dac0808 8-bit digital to analog d/a convert ic package dip-16 , ic-741 , adc0808/0809 , stepper motor , dc motor , at89s52-24pi / at89s52 ic atmel 8051 microcontroller 40 pin dip mount chip 8 bit microprocessor 8kb isp(in system programming) flash memory up to 33mhz clock frequency speed , digital communication training system , advance digital communication training system , 10 khz to 3 ghz spectrum analyser with tracking generator , 100 mhz dual channel digital storage oscilloscope , a) verify the open loop transfer characteristics of op-amp using ic-741. also determine gain of b) inverting, c) non-inverting and d) buffer amplifier using ic-741 on bread board and triner kit , design wein bridge osccillator using ic-741 on bread board and determine the frequency of oscillation. wein bridge osccillator using ic-741 , design square wave generator using ic-741 and calculate the duty cycle of the generated waveform. square wave generator using ic-741 , design an astable multivibrator using ic-555 timer and calculate the duty cycle and pulse with of the generated wave form. , design an monostable multivibrator using ic-555 timer and calculate the cycle and pulse witdth of the generated waveform , design a 2nd order active low pass, high-pass, band pass and band-reject filter using ic-741 op-amp on breadboard and trainer kit , calculate the lock range and capture range of pll using ic-565 , construct sample and hold circuit using ic-741 on bread board , kelvins double bridge test kit , wheatstone bridge test kit , d.c. potentiometer kit with 12v (d.c.) standard cell , temperature transducer kit , transformer oil dielectric strength testing kit upto 30kv , ammeter 0-5a and 0-10a - voltmeter 0-300v and 0-600v , 1-$ and 3-$ energymeter testing kit , rheostats of various ranges , digital multimeter , analog multimeter , wattmeter (0-75w), (0-150w) and (-350w) , meggar , microprocessor kit (8085 based) , trainer board of junction diode , logic gate trainer board , cro 30mhz dual trace , d/t flip-flop , common emitter transistor set , analog to digital converter interface card , 4 digit seven segment display interface card , dac kit , 8086 microprocessor trainer kit for study , intel 8051 microcontroller kit with data card , a/d converters experimental kit (adc 0800 series) , led display kit with card , lcd display kit with card , interface cards for stepper motor & dc motor control , construct the circuit and plot the , characteristics of the pn junction diode, find the cut in voltage objective : to study forward & reserve characteristics of pn juncton diode. , construct the circuit and plot the characteristics of a zener diode. find the breakdown voltage objective: to study forward & reverse v-i characteristics of zener diode. , objective: to study forward & reverse characteristics of pn junction diode , construct the circuit and plot the , characteristics of the pn junction diode, find the cut in voltage objective : to study forward & reserve characteristics of pn juncton diode. , construct the circuit and plot the characteristics of a zener diode. find the breakdown voltage objective: to study forward & reverse v-i characteristics of zener diode. , objective: to study forward & reverse characteristics of pn junction diode , construct a full wave rectifier and obtain regulation characteristics without filters and with filters. compare the results objective: to study efficiency & ripple factor of full wave & bridge rectifier on application 1 of load & filters. , construct a bridge rectifier and obtain regulation characteristics - without filters and with filters , obtain the charactersics of diac and triac , simulate half wave, full wave and bridge rectifier using simulation tool like pspice/orcad/multisim. , develop circuits simulation mod
Tender For supply of one number of karl fischer test set for testing of transformer oil water content (ppm test set) at power transformer repair unit, nallalam
Tender For supply of refilling of gases & hydraulic test of each cylinder (47 ltr.) for dga testing of transformer oil. set of gases consists of 1 set (1) hydrogen gas, grade xl qty: 1 no. (7 cum), (2) nitrogen gas, grade xl qty: 1 no. (7 cum), (3) air gas, grade xl qty: 2 no. (14 cum).
Tender For sitc of various essential equipments for the use of various municipal maternity homes - 200/250 amp. 415v tpn switchfuse unit with crca sheet steel powder coated enclosure with hrc fuses & switch links and padlockable arrangement., cable end boxes 200/250 amp. tpn switch fuse, 200 amp. 415v fp on load changeover switch with crca sheet steel powder coated enclosure., supply, installation, testing and commissioning of 50kva dg set comprising of cpcb iv mech, built in amf panel, 1500 rpm, 4 stroke, 3 cylinder inline type, water cooled with radiator diesel, 1st category al armoured cables frls outer sheathed- 3.5c x 95 sq.mm, cable end termination for aluminium cables 3.5c x 95 sq.mm, 3 noss. single core cu pvc insulated flexible cable of 50 sq.mm. for phases & 1 single core cu pvc insulated flexible cable for neutral of 25 sq.mm for 100/125 amp. tpnss switch., cement concrete foundation using m-20 cement concrete mix with j shaped foundation bolts where required, supply & laying of double wall corrugated ( dwc) pipe 125 mm od / 109 mm i.d., concrate excavating the trenches and refilling the same after the cable is laid in approved manner (size of trench: 750 mm deep, 600 mm wide) in concrete/ masonary / asphalt. 1 cu. mtr. = 2.2 rmt., soil excavating the trenches and refilling,reinstatement of the same after the cable is laid in approved manner (750 mm deep, 600 mm wide),in all types of soils 1 cu. mtr. = 2.2 rmt., providing, detailing, composite fabricating members like trusses, ngirders,girders, bracings, supports, purlins, runners, and similar structural steel members fabricated using m.s. hollow tubular steel, bare galvalume/zincalume sheets for roofing, earthing station with 600 mm x 600 mm x 6 mm galvanised iron plate, 25 x 3mm gi, bare g. i. conductor size 10 swg., removal of switchgears/ dbs upto 200 amp., removal of switchgears/ dbs above 200 amp to 400 amp., removal of busbar chamber above 100 amp tpn to 800 amp tpn., removal of cable above 3-1/2 core x 35 sq. mm. to 3-1/2 core x 70 sq. mm, removal of cable from 1.5 sq.mm to 3-1/2 core x 35 sq.mm., refixing of 2 core/ 3 core/ 3-1/2 core / 4 core/ 6 core copper / aluminium conductor armoured / unarmoured cable 1.5 sq.mm. to 16 sq.mm. size on wall / ceiling etc., refixing of 2 core / 3 core / 3-1/2 core / 4 core/ 6 core copper / aluminium conductor armoured / unarmoured cable above 16 sq.mm. to 150 sq.mm. size on wall / ceiling etc., 415v main distribution panel 1 short circuit reating 50ka for 1 sec. 400a (thermal magnetic overload, short circuit release) mccb with rotary operating mechanism as incomer with digital ammeter,, 200a 4p mccb, 100a tpn mccb, 3 noss. single core cu pvc insulated flexible cable of 95 sq.mm. for phases & 1 single core cu pvc insulated flexible cable for neutral of 50 sq.mm for 200 amp tpnss switch., g.i. cable tray with all other accessories 150 x 25mm (w x h) - (16 swg - 1.6mm) without cover, cable end termination for aluminium cables 3.5c x 50 sq.mm, cable end termination for aluminium cables 3.5c x 120 sq.mm, cable end termination for aluminium cables 3.5c x 70 sq.mm, cable end termination for aluminium cables 3.5c x 50 sq.mm, 20w led flood light luminaire ip65, 1st category al armoured cables frls outer sheathed- 2c x 6.0 sq.mm, gun metal gate valves (screwed):-50 mm dia., gun metal non - return valve: (screwed):-50 mm dia., gun metal gate valves (screwed):-15 mm dia., gun metal foot valve 50 mm dia., automatic pump control panel, hose oil cooler to water pump, worm drive hose, fuel supply pipe, injector overflow pipe (return pipe), hose for oil cooler inlet, hose clip thermostat, vent hose (epdm) for gens, ax-45-cogged belt, hose water manifold to ther, dse 6120/ 4520 controller, battery exide 12v 110ah, oil filter 4 cyl -, fuel filter 4 cyl -, air filter element outer 4 cly m&m, centrifugal oil filter 4c, radiator aluminium, radiator exhaust fan, radiator core, charging alternator, alternator winding main, alternator ar
Tender For sitc of various essential equipments for the use of various municipal maternity homes - 200/250 amp. 415v tpn switchfuse unit with crca sheet steel powder coated enclosure with hrc fuses & switch links and padlockable arrangement., cable end boxes 200/250 amp. tpn switch fuse, 200 amp. 415v fp on load changeover switch with crca sheet steel powder coated enclosure., supply, installation, testing and commissioning of 50kva dg set comprising of cpcb iv mech, built in amf panel, 1500 rpm, 4 stroke, 3 cylinder inline type, water cooled with radiator diesel, 1st category al armoured cables frls outer sheathed- 3.5c x 95 sq.mm, cable end termination for aluminium cables 3.5c x 95 sq.mm, 3 noss. single core cu pvc insulated flexible cable of 50 sq.mm. for phases & 1 single core cu pvc insulated flexible cable for neutral of 25 sq.mm for 100/125 amp. tpnss switch., cement concrete foundation using m-20 cement concrete mix with j shaped foundation bolts where required, supply & laying of double wall corrugated ( dwc) pipe 125 mm od / 109 mm i.d., concrate excavating the trenches and refilling the same after the cable is laid in approved manner (size of trench: 750 mm deep, 600 mm wide) in concrete/ masonary / asphalt. 1 cu. mtr. = 2.2 rmt., soil excavating the trenches and refilling,reinstatement of the same after the cable is laid in approved manner (750 mm deep, 600 mm wide),in all types of soils 1 cu. mtr. = 2.2 rmt., providing, detailing, composite fabricating members like trusses, ngirders,girders, bracings, supports, purlins, runners, and similar structural steel members fabricated using m.s. hollow tubular steel, bare galvalume/zincalume sheets for roofing, earthing station with 600 mm x 600 mm x 6 mm galvanised iron plate, 25 x 3mm gi, bare g. i. conductor size 10 swg., removal of switchgears/ dbs upto 200 amp., removal of switchgears/ dbs above 200 amp to 400 amp., removal of busbar chamber above 100 amp tpn to 800 amp tpn., removal of cable above 3-1/2 core x 35 sq. mm. to 3-1/2 core x 70 sq. mm, removal of cable from 1.5 sq.mm to 3-1/2 core x 35 sq.mm., refixing of 2 core/ 3 core/ 3-1/2 core / 4 core/ 6 core copper / aluminium conductor armoured / unarmoured cable 1.5 sq.mm. to 16 sq.mm. size on wall / ceiling etc., refixing of 2 core / 3 core / 3-1/2 core / 4 core/ 6 core copper / aluminium conductor armoured / unarmoured cable above 16 sq.mm. to 150 sq.mm. size on wall / ceiling etc., 415v main distribution panel 1 short circuit reating 50ka for 1 sec. 400a (thermal magnetic overload, short circuit release) mccb with rotary operating mechanism as incomer with digital ammeter,, 200a 4p mccb, 100a tpn mccb, 3 noss. single core cu pvc insulated flexible cable of 95 sq.mm. for phases & 1 single core cu pvc insulated flexible cable for neutral of 50 sq.mm for 200 amp tpnss switch., g.i. cable tray with all other accessories 150 x 25mm (w x h) - (16 swg - 1.6mm) without cover, cable end termination for aluminium cables 3.5c x 50 sq.mm, cable end termination for aluminium cables 3.5c x 120 sq.mm, cable end termination for aluminium cables 3.5c x 70 sq.mm, cable end termination for aluminium cables 3.5c x 50 sq.mm, 20w led flood light luminaire ip65, 1st category al armoured cables frls outer sheathed- 2c x 6.0 sq.mm, gun metal gate valves (screwed):-50 mm dia., gun metal non - return valve: (screwed):-50 mm dia., gun metal gate valves (screwed):-15 mm dia., gun metal foot valve 50 mm dia., automatic pump control panel, hose oil cooler to water pump, worm drive hose, fuel supply pipe, injector overflow pipe (return pipe), hose for oil cooler inlet, hose clip thermostat, vent hose (epdm) for gens, ax-45-cogged belt, hose water manifold to ther, dse 6120/ 4520 controller, battery exide 12v 110ah, oil filter 4 cyl -, fuel filter 4 cyl -, air filter element outer 4 cly m&m, centrifugal oil filter 4c, radiator aluminium, radiator exhaust fan, radiator core, charging alternator, alternator winding main, alternator ar