Tender For supply of positive temperature coefficient thermistor relays, etm make: - eaton moeller/substantially equivale , rogowski coils current transducers with output, 4-20 ma range: - 10-40 a, model no- senca t 201 mak , industrial relay with socket 2 pole, co(n pdt) up to 10 a with socket make- finder/substantially e , control gear contactor tc 40 with aux contact block make-tc/ eaton moeller/substantially equivalen , control gear contactor current rating-32 a with aux. contact block make- eaton moeller/substantial , switchgear mccb nzm ratingup to 100 a, 3 pole make- eaton moeller/substantially equivalent , control gear contact block type- no, model no- m22-k10 makeeaton moeller/substantially equivalen , control gear contact block type-nc, model no- m22-k01 make- eaton moeller/substantially equivalent , control gear local remote switch make- eaton moeller/substantially equivalent , motor protection circuit breaker rating- 7-10 a makeeaton moeller/substantially equivalent , multifunction measuring unit model no- diris a-20 make- socomac/substantially equivalent , switchgear mccb model- tmax t5n400 makeabb/substantially equivalent , switchgear mccb model- tmax t1n160 make- abb/substantially equivalent , vacon drive function monitor makevacon/danfoss/substantially equivalent , bussmann series high speed square body fuse model- 170m5, rating- 700 a makebussmann/substantial , din 1/8 programmable digital panel meters a/v current- 5a/1a, voltage600 v ac make- frer/substan , switch mode power supply input voltage- 230 v, output voltage- 24 v, current rating- 10 a make- p , control transformer rating- 1 kva, 415/230 v ac, class-f make- trasfoproject/substantially equiv , motor protection circuit breaker rating- 1-1. 6 a, model no- pkzmo 1. 6 make- eaton moeller/substan , motor protection circuit breaker rating- 4-58 a, model no- pkzm4-58 make- eaton moeller/substanti
Tender For replacement of 1x8mva, 66/11kv by 1x20mva, 66/11kv power transformer at 66/11kv punabghatta in harpanahalli tq, vijaynagara district. on partial turnkey basis, including supply of all materials/equipments testing and commissioning (excluding supply 20mva power transformers and 11kv switchgear) call-2.
Tender For replacement of existing 2x10mva. 110/11kv by 2x20mva, 110/11kv power transformer and providing additional mcvcb switchgear at 110kv sirigeri cross s/s in siruguppa tq. ballari dist. on partial turnkey basis call-2.
Tender For provision of store room at offrs mess diesel generator set for class rooms jcos or courses located adjacent to kta trg shed in drone trg area and special repairs to power distribution boards switchgear under ge i gos
Tender For corrigendum : providing new bank-3 along with 1cx1000sqmm ug cable run from 31.5mva power transformer-2 to new bank-3 at 66/11kv alur substation coming under operations division, nelamangala in bengaluru north taluk, bengaluru urban district on partial turnkey basis including supply of all matching materials/equipments (excluding switchgear) and erection (including civil works) of all materials/equipments, testing and commissioning.