Get complete information related to latest Bearing Axle Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Bearing Axle Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Bearing Axle Repair Tenders.
Tender For supply of cylindrical roller bearing for d-end of medha motor of skf make bearing n o. nu 322 ecmra/c4hva3091r2 ( imported make) or medha part no. sptsa700099p0003 or sch aeffler bearing fag f-585063.zl-m15cs-m32n.
Tender For corrigendum : supply of supply of impeller 2 b22 1131 m1 rev 1 p c 7dip0102b00221131m01,supply of inlet 3 138417 1 p c cpu3mu31384170xxxxx,supply of pump casing 1 138416 1 1 p c bpu4qv11384161xxxxxx,supply of shaft complete part 2 195313 m1 pc 7dsc0861953130000m01,supply of oil seal 954168 part 1 type a 40x55x7 p c b3z40xx55xx7xxxxxxxpx,supply of oil seal 953319 part 1 type a 40x55x7 b3z50xx68xx8xxxxxxpx,supply of cylindrical roller bearing series nu3 pc bblebsd03cn00181800x,supply of bearing deep groove ball bearing bbld3sd03cn00181800x,supply of sealing ring g4 157734 1 7dsn0901577340000001,supply of sealing ring g4 157938 1 bpu4fv415793810xxxxx
Tender For corrigendum : e-bid for rate contract cum supply and empanelment of surgical items - blood administration set / blood transfusion set sharp and easy piercing spike suitable for blood bags and standard blood containers transparent cylindrical drip chamber with filter.filter size should be 200+20 micrometer. 150 cm long smooth kink resistant tubing efficient roller clamp to control and adjust the transfusion rate as per is 9824 (part 3):1996, suction catheter, sterile. size: fg 5 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cms (min.) as per is0 8836:2014, suction catheter, sterile. size: fg 6 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cm (min.) as per is0 8836:2014, suction catheter, sterile. size: fg 8 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cm (min.) as per is0 8836:2014, suction catheter, sterile.size: fg 10 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cm (min.) as per is0 8836:2014, suction catheter, sterile. size: fg 12 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cm (min.) as per is0 8836:2014, suction catheter, sterile. size: fg 14 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment. length 50 cm (min.) as per is0 8836:2014, suction catheter, sterile. size: fg 16 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cm (min.) as per is0 8836:2014, suction catheter, sterile.size: fg 18 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment. length 50 cm (min.) as per is0 8836:2014, suction catheter, sterile. size: fg 20 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment. length 50 cm (min.). as per is0 8836:2014., suction catheter, sterile. size: fg 22 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye. colour coded universal funnel connector for safe connection to standard suction equipment. length 50 cm (min.). as per is0 8836:2014, sterile catheter, single use, for urinary drainage (foley balloon catheter), 2 way, size 8 fg made of silicone elastomer bonded with latex should have hard plastic valve smooth distal end with smooth eyes for atraumatic intubation. symmetrical foley balloon balloon capacity 3- 5 ml as per is 11497 color coding marking to identify size. length, wall thickness and balloon capacity should be mentioned as per is 11497. specification for b,c,d,e,f,g should be mentioned as per is 11497 for particular size, sterile catheter, single use, for urinary drainage (foley balloon catheter), 2 way, size10 fg made of silicone elastomer bonded with latex should have hard plastic valve smooth distal end with smooth eyes for atraumatic intubation. symmetrical foley balloon balloon capacity 3- 5 ml as per is 11497 color coding marking to identify size length, wall thickness and balloon capacity should be mentioned as p