Tender For supply, installation, testing and commissioning of floating log boom barrier system in dam reservoir of chamera-ii power station karian, chamba himachal pradesh
Tender For corrigendum : tender for supply of c17m260048 procurement of boom barrier in plant gate entry - boom barrier , anpr cctv camera system , outdoor led display unit , rfid handheld reader , software & server cost , install test & commissioning , transportation
Tender For operation and maintenance of 11kv sub station equipment, 500kva/320kva/125kva dg sets, internal electrical installations, water supply pump sets, addressable fire alram system, ac plant, vrf system, fire fighting system, boom barriers and lifts at niti aayog, new delhi for the fy 2026-27. sh - repairing and annual preventive and periodical maintenance of 83hp wet riser system diesel engine of kirloskar make.subwork/packages:repairing and annual preventive and periodical maintenance of 83hp wet riser system diesel engine of kirloskar make
Tender For supplying, providing, installing and commissioning of smart real time gate position and auto pn system which includes 10.1" display module with touch screen for sm unit and lc unit, interactive ui to clearly display train number and gate position on the sm unit and lc units, 4g connectivity with fallback to 3g/2g where 4g network is not present, sensors to detect the position of lc gate boom and boom locking lever, sensors capable of interchangeable and also identify if the gate is locked. sensor shall have weather proof casing, lc unit interacts with sensors continuously to detect the position of gate boom/boom-locklever and generate auto - pn only when both the conditions satisfied i.e. boom is closed condition and leveroperated for boom locking. sm unit generates auto pn when sm enters train number, up/dn details. lc unit has auto pn generated when the gate is identified as closed and boom lock lever operated, after the sm command, lc unit shall report the status of the gate whenever changed its position and status of lc gate position on sm unit shall be indicated by red icon when gate is in open condition and that is by green icon when gate is in closed condition, sm unit and lc units are connected by wireless equipment. fail safe measures are also implemented along with backup and database from where each and every operation that isrecorded between the gateman and the station master, which can be viewed. the rate is including all tools,plants, labour, transportation, manpower including cost of cloud subscription and 4g/3g data plan for 1 year at contractor's own cost inclusive of all taxes as applicable. providing track indicator, lever lock arrangement with iot, and interlocking all the above with pn exchange so as to stop unauthorised opening of ctrt and otrt gates. with 1 year maintenance against all kinds of failures physical and functional, installation and operation. warranty on hardware minimum 2 years. any other modifications and addition as per engineers instructions. the execution of works for the non interlocked lc gates under sse/pway/bdo(from sr.no. 1 to 6) and under sse/p.way/cbsa (from sr.no. 7 to 12) are furnished in annxure- a (enclosed) [ warranty period: 30 months after the date of delivery ] ]
Tender For planning, design, construction, testing and commissioning, certification, validation of biosafety level-3 (bsl-3) laboratory (g plus 1 floor) in epc mode-i under pm-abhim for national centre for disease control (ncdc) at kims, hubballi, karnataka inclusive of (i) obtaining of all local body approvals, eia, consultancy services (architectural, structural & mep), modular pre-fabricated wall panel & pre fabricated ceiling panel, epoxy flooring, doors, drains, water supply piping in bsl-2/3 lab containment area, sanitary installation, internal roads, parking facilitation, ug sump, terrace water tank, water supply lines, storm water drains, external sewerage system, service trenches, demolishing of existing structure, retaining walls, internal electrical installations, fire alarm system, fire fighting system, lifts, sub station, dg sets, ups, air conditioning system (hvac & vrv/vrf), cctv, access control system , ibms, lan, ip based epabx system, audio visual system, boom barriers,subwork/packages:etp equipment and street lighting etc., (ii) design, supply, installation, testing and commissioning of all equipment for bsl-3 & bsl-2 lab. (iii) certification, validation, commissioning of bsl-3 lab facility from third party validation agency. (iv) operation of complete facility for 5 years, annual maintenance during 3 years defect liability period plus 2 years comprehensive maintenance of complete bsl-3 lab facility including all equipment after 3 years dlp including annual validation
Tender For supply of barrel bush suitable for 4.5kw alternator belttensioningdevice as per scr drg.no:cee-scr-001/06/2014 (drawing is enclosed) [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of supply of 3 core 2.5 sqmm, fr lsh pvc insulated industrial grade copper conductor flexible cables, 1100 volts conforming to is 694. , supply of 4 core 4 sqmm, fr lsh pvc insulated industrial grade copper conductor flexible cables, 1100 volts conforming to is 694. , supply of 4 core 10 sqmm, fr lsh pvc insulated industrial grade copper conductor flexible cables, 1100 volts conforming to is 694. , supply of 3 to 3.5 mtr telescopic boom arm suitable for time watch boom barrier , supply of 400mm sweep pedestal fan with plastic body and blades, height adjustable with standard accessories suitable for operation on 230v, single phase ac supply etc., as required , supply of 400mm sweep wall fan with plastic body, mounting arrangement with standard accessories suitable for operation on 230v,single phase ac supply etc., as required. , supply of following, c curve, miniature circuit breaker suitable for operation on 230 415 v, ac supply, 10 ka breaking capacity of following poles etc. as required. 6 a to 32 a sp mcb , supply of following, c curve, miniature circuit breaker suitable for operation on 230 415 v, ac supply, 10 ka breaking capacity of following poles etc. as required. 20 a dp mcb , supply of following, c curve, miniature circuit breaker suitable for operation on 230 415 v, ac supply, 10 ka breaking capacity of following poles etc. as required. 20 a tp mcb , supply of following, c curve, miniature circuit breaker suitable for operation on 230 415 v, ac supply, 10 ka breaking capacity of following poles etc. as required. 40 a fp mcb , supply of following, c curve, miniature circuit breaker suitable for operation on 230 415 v, ac supply, 10 ka breaking capacity of following poles etc. as required. 63 a fp mcb , supply of 40 a, double pole, residual current circuit breaker rccb, having a sensitivity current 100 ma suitable for operation on 230 v, single phase ac supply etc. as required. , supply of 63 a, four pole, 415 volts, residual current circuit breaker rccb, having a sensitivity current 300 ma suitable for operation on 415 v, single phase ac supply etc. as required. , supply of iro pro uo r relay c and s make.under voltage over voltage relay. , supply of four pole, contactor with ac 1 rating 40a and 230v ac coil voltage , supply of 2no plus 2nc 10a, contactor with 24v dc coil. , supply of 2no contractor with 24 v dc coil. make schneider model a9c20132 or equivalent , supply of 2mp dome camera suitable for existing cctv system. make honeywell, part no impact i hee2pl lp , supply of 2mp bullet camera suitable for existing cctv system. make honeywell, part no impact i hibb2pi lp , supply of media converter suitable for existing cctv system. make tricom , supply of poe switch 8 port suitable for existing cctv system. make dlink. , supply of sim based gsm autodialer along with 24v 2amp smps suitable for existing fire alarm system including . make pinnacle.
Tender For corrigendum : provision with comprehensive annual maintenance (2 years) of elv system (pa system, cctv, lan, epabx and boom barrier system) of all building at 650 bedded teaching hospital, balangir
Tender For supply of electro magnetic boom locking system with positive boom locking. (led indicator panel with buzzer required andindication circuit). as per drawing & specification attached. approval of sample material should be taken from consignee befor bulk supply. material should be supply at consignee depot sse/s/m/ jbp. [ warranty period: 30 months after the date of delivery ] ]