Web Analytics Made Easy - StatCounter

Billboard Panel Scrap Tenders

Get complete information related to latest Billboard Panel Scrap Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Billboard Panel Scrap Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Billboard Panel Scrap Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

corporations/Associations/Others

CTN :42889518 Due date: 29 Nov, 202529 Nov, 2025 15.00 Lacs
Tender For arrangements of canopies chairs tables carpet and other required items on hire basis for water distribution points at various locations in view of the bhavani deeksha viramana 2025 in circle 1 area (1st call)

State Government

CTN :42849701 Due date: 11 Dec, 202511 Dec, 2025 NA
Tender For work of providing and fixing safeguard/canopies at various auxiliaries of 210mw bhusawal tps

Central Government/Public Sector

CTN :42825963 Due date: 09 Dec, 202509 Dec, 2025 42.65 Lacs
Tender For provision of pol stores for microlight base elect section tool crib addn altn of roof sheet provn of view cutters and other allied work at certain location of af station under ge af bamrauli - surface dressing n exc 15 cm deep in soft/loose soil, complete all as specified and directed., excavation in trenches for n.exc 1.50m wide not exceeding 10 sqm on plan and n.exc 1.5m in depth in soft/ loose soil and getting out, complete all as specified and directed., excavating over areas hard & dense soil, n. exc 1.5 m deep and getting out, complete all as specified and directed., m&l for pcc 1:4:8 type d2 graded stone aggregate cement concrete in flooring, foundation, filling and mass, complete all as specified and directed., returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. complete all as specified and directed., removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m. complete all as specified and directed., m&l for hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface, complete all as specified and directed., m& l for rcc type b1, (1:2:4) nominal mix (20mm grade aggregate) foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc., basement slabs, complete all as specified and directed., m&l for rcc (20mm grade aggregate type b1 (1:2:4) nominal mix columns, pillars, piers, posts and struts, complete all as specified and directed., m&l for rcc type b1, (1:2:4) nominal mix (20mm grade aggregate slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as specified and directed., m&l for rcc type b1, (1:2:4) nominal mix (20mm grade aggregate) beams, cantilevers, bressummers, lintels over 1.5m span all as specified and directed., m&l for rcc type b1, (1:2:4) nominal mix (20mm grade aggregate to chajjas, complete all as specified and directed., m&l for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work, vertical or to batter, complete all as specified and directed., m&l for formwork to sides of pillars, posts, struts, piers, columns and stanchions, complete all as specified and directed., m&l for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (horizontal or sloping), complete all as specified and directed., m&l for formwork to sides and soffits of floor or roof beams, beam haunch ings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed., m&l for formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of rcc/pcc bands in walls, horizontal or sloping, and similar work all exceeding 20cm wide, complete all as specified and directed., s&f for mild steel tmt bars 10mm dia and over, cut to length, bent to shape required, includingcranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed., s&f for mild steel tmt or twisted bars 6 to 8 mm dia as reinforcement for concrete, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia as in stirrups etc. complete all as specified and directed., m& l for pcc 75mm thick type c-1 ,1:3:6 using 20mm graded stone aggregate as in plinth protection, complete all as specified and directed., m&l for brick work with sub class b bricks, straight or curved on

Corporations And Associations And Others

CTN :42805507 Due date: 25 Nov, 202525 Nov, 2025 3.30 Lacs
Tender For improvement and development of electrical installation and fans at mcd primary school neb sarai ward no 160 under south zone - rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm frls pvc insulated copper conductor single core cable as earth wire in existing surface/recessed steel/pvc conduit including dismantling as required. group c, wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. group c, supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surfac/recessed steel/ pvc conduit as required. (a) 3 x 2.5 sq. mm, 6 x 2.5 sq. mm, 3 x 4 sq. mm, 3 x 6 sq. mm, brush less direct current (bldc) motor supply, installation, testing and commissioning of ceiling fan with brushless direct current (bldc) motor, class of insulation: b, 3 nos. metal( aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit,safety rope, copper winding, steel/al body power factor not less than 0.9, service value (cm/m/w) minimum as below, 350 rpm (tolerance as per is :374-2019), thd (total harmonic distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree c (max.), insulation resistance more than 2 mega ohm, suitable for 230 v, 50hz, single phase ac ceiling fan compliant to is 374:2019 fan supply,earthing etc. complete as req 1200mm, service value 6.0 cm/min/watt, air delivery 210 cm/min (minimum) 1200mm, service value 6.0 cm/min/watt, air delivery 210 cm/min (minimum), supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. (a) 5/6 amps switch, 3 pin 5/6 a socket outlet, 15/16 a switch, 6 pin 15/16 a socket outlet, supplying and fixing of following sizes of medium class pvcconduit along with accessories in surface/recess includingcutting the wall and making good the same in case of recessedconduit as required. 20mm, supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. (a) 150 mm x 75 mm x 60 mm deep, 200 mm x 250 mm x 60 mm deep, 250 mm x 300 mm x 60 mm deep, supply and fixing of 3 mm thick phenolic laminated sheet, led batten light (system lumen efficacy 105 120 lm/watt) supplying, installation, testing & commissioning of led surface mounted batten light of following body material and construction as per is : 10322 with driver (replaceable) as per the requirement with driver efficiency >85% ,operating voltage ac 140-270 volt, freq 50/60 hz, operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 kv with short & open circuit protection ,thd 10% , p. f. 0.95, ip20, cri >80, flicker free, (flicker should be below 5 %), life time (led,driver & electrical circuitary), of minimum 50000 burning hours with , 70% of initial lumen maintained till life ends, cct 3000 k / 4000 k / 5700 k /6000 k/6500 k (as per ansi bin), sdcm(standard deviation color matching) 3, maximum power consumption should not more than the specified rating and fixture shall be of relevant bis standard and trade mark certificate ( t.c.). manufactures word mark/ name engraved/ embossing/ screen printing on housing. complete in all respect i/c connections with 1.5 sq mm frls, pvc insulated copper conductor single core cable and earthing etc. as required with minimum 5 year oem warranty. system lumen efficacy 105 120 lm/watt output . lm79 &
 Loading, Please wait...

Connect us via What's Up