Tender For set of carline for memu dmc 3-phase coaches with high rise panto & tcas facility, as per drawing: mp26cardmc version 0, packing instruction: carline assly the supplier shall pack the three c/set (segments) of carlines in a suitably designed robust returnable metallic cage/structure in such a way that carlines shall not get entangle, damaged, twisted, dented during transportation, storage, handling and lifting and to avoid scratches on outer surface suitable environment friendly cushioning material is to beplaced between two segments, transit damage if any shall be at the cost of supplier. the packing cage/structure to be fabricated by using sq. tubes channels/angles having sufficient strength to bear approximate 1.5 tonne material load in static & moving condition of three coach set of carline. the bottom part of this packing cage/pallet should be such that curvature profile of bottom carline should match with the profile of packing cage and it can accommodate fork lifter arms for lifting and transportation. it should have standard clamping/fastening mechanism to facilitate easy unpacking & unloading. it should have firm's identification/color mark. the packing cages along withset of carlines supplied in one lot be retained by rcf & this cage set shall be exchanged in the second lot supply and so on. at the end of the contract, the firm shall collect the remaining returnable packing cages from rcf. it should also be suitable for storage of carline under open sky. packing slip should be pasted on each cage showing p.o. no., pl no., description,drg. no./spec, , qty. , firm's name and address & despatch date etc. for identification. [ warranty period: 30 months after the date of delivery ] ]
Tender For bid to ras tender for supply of disconnecting ht and lt supply taking down the defective transformer indoor outdoor type from four pole two pole structure or lifting from the outdoor type foundation or taking out from sub station bldg using a crane of suitable capacity and slings ropes etc as required and shifting the same to civil workshop for repairs complete all as directed for transformer capacity 400 kva , shifting back the repaired transformer indoor outdoor type from civil workshop to site reinstalling at original position and fixing properly on four pole two pole structure or outdoor type foundation or inside a sub station bldg using a crane of suitable capacity and slings ropes etc as required making ht lt side connections and testing for satisfactorily working complete all as directed for transformer of capacity 400 kva , draining out transformer oil from the transformer and storing the same in suitable containers to be arranged by contractor without any extra cost opening the top cover and lifting up the core assembly carefully to check the condition of transformer windings and core retanking the same after repairing checking of leakage from transformer body and repairing welding works required for making transformer body leak proof refilling the transformer oil dully dehydrated and filtered dehydration and filteration to be paid separately and making all connections with ht lt side bushings refixing the top cover and testing the transformer with a suitable capacity insulation tester complete all as directed for transformer of cap 400 kva , m and l for rewinding of burnt out defective ht copper coils with new super enamelled heavy duty copper winding wires of size matching to the existing one including varnishing drying in a suitable oven and all insulating material such as cotton sleeves tapes etc and connections with bushing terminals complete all as specified and directed , all as per item no 4 above but lt copper coils complete all as specified and directed , m and l for painting the transformer tank from inside with two coats of zinc chromite after preparing the tank walls bottom top cover inner side by properly cleaning the surfaces oil free complete all as directed for transformer capacity 400 kva , m and l for replacement of defective ht porcelain bushing of suitable size for transformer of cap 400 kva including washers of good quality complete all as specified and directed , m and l for replacement of defective lt porcelain bushing of suitable size for transformer of cap 400 kva including washers of good quality complete all as specified and directed , dehydration and filteration of transformer oil for indoor outdoor type transformers of any capacity at site using transformer oil filteration plant to improve di electric strength not less than 45 kv at 2 point 5 mm electrode gap complete all as directed note unit rate quoted shall be deemed to include the charges for hiring of oil filteration plant shifting to different locations at cantt area testing of samples of oil as per requirement and nothing extra will be paid on this account , s and f new transformer oil for replacement or topping up the level of oil having dielectric strength not less than 45 complete all as specified and directed
Tender For painting and replacement of rubber seal work of 7 nos. radial gates, 9 nos. of leafs of stoplog gates, gantry crane, 2 nos. of both service and emergency gates and structure of lbc, 1 nos. of gate and structure of rbc for upper beda medium irrigatin - painting & replacement of rubber seal work of 7 nos. radial gates, 9 nos. of leafs of stoplog gates, gantry crane, 2 nos. of both service and emergency gates and structure of lbc, 1 nos. of gate and structure of rbc for upper beda medium irrigatin project district khargone (m.p.) including material, labour, charges, connection and testing etc. complete work.
Tender For auction of the govt. sr. sec. school kankrola(gurugram) old and unsafe building for the purpose of site clearance of dismantling material of the existing structure including demolition of dilapidated building/rooms, taking possession of salvaged material on "as is where is"
Tender For supply of materials and erection for shifting of control room pannel at 33/ 11 kv sub station bharsawa distt. kaushambi under deposit scheme on "semi turnkey basis" under edc, kaushambi - name of work: supply, carriage & erection of materials for control room pannel shifting of shiffting of 33/11 kv s/s bharsawa distt. kaushambi, supply of de-centralised materials, 11 kv 3x120 mm2 xlpe cable jointing kit o/d & i/d, control cable 4x2.5 mm2, control cable 2x2.5 mm2, g.i. pipe 6 " dia, rubber matting, clamp with nut & bosts, earth wire clamp for pcc pole, stay clamp for pcc pole, top channel clamp pcc pole, dropper channel clamp pcc pole, g.i. strip 35x6 mm, carriage of following material, pcc pole 8.5 mtr. long., structure of la, 33kv isolator, 33 kv cts, single t/f control pannel, 33kv vcb,11 kv outgoing. incoming pannel, battery & battery charger and other associated accessiories etc. (availibility at concern store center of store division), erection work, installation of 33 kv single transformer control pannel 2 no., incoming 2 no. and 7 no. outgoing in the switchgear room and grouting the pannel by rag bolt using cement, sand mortar in ratio 1:3. work includs fitting of all accessories in all respect with complete connection of control cable with pannel. all material will be provided by the contractor except vcb and crp., construction of cable trenchs with top cover and laying of control cable for vcb, c.t. & t/f control pannel etc. as per direction of engineer. trenchs to be 12 wide and 9 deep. work includes digging, of trench, concreting of the foundation in the ratio 1:3:6 r.b. wall 9 wide with cement mortar 1:4 and plastering inside the trench in the ratio 1:3 and sand filling in the trench. all material will be provided by the contractor., earthing of 11 kv indoor equipments, switchgears as per resspo drawing. with g.i. strip of size 35x6 mm. g.i. strip fully welded at both ends and to be connected with earthmat,, erection of dp with pcc pole 8.5 mtr long with all accessaries and grouting of the pcc pole with cement, sand and brick ballast ratio 1:4:8 size 0.45x 0.45x 1.5 mtr deep under the ground as per drawing no. res-6.(cement, sand, brick, ballast shall be provided by the contractor.), installation of 24 volt battery and battery charger with cabinet in the switch gear room, by grouting base channel 100 x 50 x 6 x 1000mm. fixing of rag bolt., laying of 11 kv 3x300/3x185/ 3x120 sqmm. xlpe cable by digging 0.75 mtr. deep trench, putting layer of sand in the bottom, ramming it, laying of cable over it rmt and covering the cable from sides and top by laying bricks, finally covering the same by earth and levelling of the same, all the materials, except cable, will be pvovided by the contractor., fixing and termination of outdoor/ indoor heat shrinkable cable boxes of size 3 x300/3x185/3x120 sqmm. xlpe cable. boxes will be supplied by the contractor, sundries ( as per site requirement/emergency work), safe dismantling of 11 kv o/g pannel & received back to store, laying of weasel conductor with the help of aluminium roller by hanging three nos. on each support in a manner taking sufficient care to ensure safety of weasel conductor against rubbing on ground, precaution for safety of crops is also to be taken. the work includes jointing of conductor by providing jointing sleaves, stringing of conductor upto correct sag and binding of conductor with insulators on each support. all material shall be provided by contractor such as jointing sleeve binding wire, armour rod etc.
Tender For auction sale of depot ferrous scrap - scrap ferrous melting consisting of coach cutting parts, doors,window &seat bearthnframe, eq.stay,foot step, foot rest plte, m.s. & g.i pipes & sheets, pipe fittings, fabricated structure,wire & wire rope,plane & twisted bar, shock-absorver & damper without cutting, shuckle stone, side frame key, brake shoe head,brake-beam, gear case, lower spring seat, bmbc cover,follen rod,bond strip, protective tube,tirfor,rachit, pull lift, m.s. chain, nut,bolt,washer, cutter, locking plate, expended metal, slack- adjuster, u-type bracket, clamp, trd bracket,empety electric pannel box switch board, nos-plate, wheel barrow, pandrol clip, battry box,rake blast, crusible & its parts, broken helical spring up to single coil & helical spring up to three coil, pipe &tie bar fancing, signal ladder,signal box, signal pols& other various items fit for melting released from carriage, sig, electric,trd, loco, tmc,p.way of sorts & sizes with steel,c.i., & neg. n.f. attechment if any. note :-1. loading by purchaser. 2. delivery not allowed against part payment. 3. cutting allowed for loading purpose during at the time of loading. 4. if items found other than melting at the time of cutting & loading will be seperated & not delivered to purchaser. 5. material should be delivered in sequence as per location mentioned above. location-lying at 02 (two) places at travereser- 1) line no.-11 near boundary wall. 2) near tree no. g-03 in plot- g.
Tender For tender for supply of equipment / material , design, erection, testing & commissioning for sop to civil hospital jawalamukhi by providing 11/0.4 kv, 400 kva dtr a/w 11 kv ht line in electrical section amb under esd hpsebl no-i jawalamukhi, ed jawalamukhi. - supply part of 11 kv ht line with aaac 7/3.81 (0.065 km), steel tubular poles 11 mtr. long with base plate, muff for steel tubular pole with concrete filling, aaac conductor 7/3.81, 80 sq. mm ( includes 3 conductor length and additional 1% sag (sag, jumpering and wastage)), single continuous earth wire (g.i wire 8 swg), cross-arm {channel iron (100x50x6 mm), length 1270 mm}, 11 kv pin insulators ( porcelain, 12 kv, 10 kn): 3 no. per pole structure, ai (50x50x6 mm), length 750 mm x2 no., x-bracing set -ms angle iron 50x50x6, length {2125 mmx2 no }, pole top bracket (100x50x6 mm), length 100 mm, ht stay set complete, stay wire, earthing set ht complete in all respect, eye hook for earth wire, barbed wire (rec sp f 3-1981), half clamp, full clamp, danger plate (250x200x1.6 mm), nuts & bolts off sizes, 11 kv g.o. switch, d.o fuse unit, aluminium paint, red oxide point, supply part of 11/0.4 kv 400 kva distribution sub-station, steel tubular poles 9 mtr. long, muffs with concerete filling, x-arm: [channel iron (100x50x6 mm), length : 2800 mm x 2 nos], ms angle iron (50x50x6 mm), length: 2800 mm x(1 nos for las), x-arm: [channel iron (75x40x6 mm), length : 2800 mm x 4 nos] for supporting do fuse unit & go switch, x-arm [channel iron (100x50x6 mm), length : 2800 mm x 2 nos for transformer bed, x-arm [channel iron (100x50x6 mm), length : 460 mm x 2 nos for supporting main channel of transformer, ms angle iron (50x50x6 mm), length : 2800 mm x 2 nos, ms angle iron 35x35x5 mm), length : 460 mm x 2 nos, ms angle iron 50x50x6 mm), length : 950 mm x 2 nos for bed knee bracing, ms angle iron (50x50x6 mm), length : 2800 mm x 2 nos for lt distribution box and go switch assembly, ms angle iron (50x50x6 mm), length : 450 mm x 1 nos for lt distribution box and go switch assembly, go switch handle supporting : [ channel iron (75x40x6 mm), length:460 mm, go ab switch unit (11kv, 400a, 25 ka ) triple pole o/d type, d.o fuse unit, surge arrester, 9 kv station class (porcelain type), discs insulator sets (comprising 1 no. disc: ^^(porcelain, bs, 12 kv, 90 kn) including dead end clamps etc.), stay set complete, stay wire, pipe earthing set, gi wire (6 swg) earth wire, half clamp (m.s. flat 50x6 mm), full clamp ( m.s flat 50x6 mm), nuts and bolts of various sizes (galvanised / coated), aluminium thimble 300 sq mm, copper thimble 95 sq mm, danger plate, barbed wire, lt cable 3.5 core 400 sq. mm, lt cable 3.5 core 70 sq. mm, aluminium paint., red oxide, transformer bed (civil work), chain link fencing, angle iron, gate etc. for transformer fencing, ct pt combined unit, energy meter (3-ph, 4-wire) dlms compliant 1000/5 a ct type for 400 kva dtr, pvc multistrand 2.5 sq mm copper wire, ms angle iron (50x50x6 mm) length 2800 mm x 4 nos., ms angle iron (50x50x6 mm) length 450 mm x 2 nos., erection part of 11 kv ht line, erection charges & transportation charges complete in all respect of 11 kv ht line, erection part of 400 kva dtr, erection charges & transportation charges complete in all respect of 11/0.4 kv, 400 kva dtr
Tender For tender for supply of equipment/material, design, erection, testing commissioning for sop to jsv by prov. 11/0.4 kv, 25 kva dtr at bohal khalsa a/w 11 kv ht line in electrical section bharoli under esd hpsebl no-i jawalamukhi ed jawalamukhi - supply part of 11 kv ht line with aaac 7/3.81 (0.692 km), steel tubular poles 10 mtr. long, steel tubular poles 9 mtr. long, muff for steel tubular pole with concrete filling, aaac conductor 7/3.81, 80 sq. mm ( includes 3 conductor length and additional 1% sag (sag, jumpering and wastage)), single continuous earth wire (g.i wire 8 swg), cross-arm {channel iron (100x50x6 mm), length 1270 mm}, 11 kv pin insulators ( porcelain, 12 kv, 10 kn): 3 no. per pole structure, ai (50x50x6 mm), length 750 mm, x-bracing set -ms angle iron 50x50x6, length {2125 mmx2 no }, pole top bracket (100x50x6 mm), length 100 mm, ht stay set complete, stay wire, earthing set ht complete in all respect, barbed wire (rec sp f 3-1981), half clamp, full clamp, danger plate (250x200x1.6 mm), nuts & bolts off sizes, discs insulator sets (comprising 1 no. disc: ^^(porcelain, bs, 12 kv, 90 kn) including dead end clamps etc.), safety & maintenance equipment for line maintenance, ci 100x50x5 mm length 2340 mm, belt ai 50x50x6 mm length 1800 mm, aluminium paint, supply part of 11/0.4 kv 25 kva distribution sub-station, steel tubular poles 9 mtr. long, muffs with concerete filling, distribution transformer 11/0.4 kv, 25 kva, x-arm: [channel iron (100x50x6 mm), length : 2800 mm x 2 nos], ms angle iron (50x50x6 mm), length: 2800 mm x(1 nos for las), x-arm: [channel iron (75x40x6 mm), length : 2800 mm x 4 nos] for supporting do fuse unit & go switch, x-arm [channel iron (100x50x6 mm), length : 2800 mm x 2 nos for transformer bed, x-arm [channel iron (100x50x6 mm), length : 460 mm x 2 nos for supporting main channel of transformer, ms angle iron (50x50x6 mm), length : 2800 mm x 2 nos, ms angle iron 35x35x5 mm), length : 460 mm x 2 nos, ms angle iron 50x50x6 mm), length : 950 mm x 2 nos for bed knee bracing, ms angle iron (50x50x6 mm), length : 2800 mm x 2 nos for lt distribution box and go switch assembly, ms angle iron (50x50x6 mm), length : 450 mm x 1 nos for lt distribution box and go switch assembly, go switch handle supporting : [ channel iron (75x40x6 mm), length:460 mm, go ab switch unit (11kv, 400a, 25 ka ) triple pole o/d type, d.o fuse unit, surge arrester, 9 kv station class (porcelain type), discs insulator sets (comprising 1 no. disc: ^^(porcelain, bs, 12 kv, 90 kn) including dead end clamps etc.), stay set complete, stay wire, pipe earthing set, gi wire (6 swg) earth wire, lt distribution panel box for 25 kva dtr, half clamp (m.s. flat 50x6 mm), full clamp ( m.s flat 50x6 mm), nuts and bolts of various sizes (galvanised / coated), aluminium thimble, copper thimble, danger plate, barbed wire, lt cable 3.5 core 70 sq. mm, aluminium paint., red oxide, energy meter (3-ph, 4-wire) dlms compliant 50/5 a ct type for 25 kva dtr, lt switched capacitor 9 kvar for 25 kva dtr, erection part of 11 kv ht line, erection charges & transportation charges complete in all respect of 11 kv ht line, erection part of 25 kva dtr, erection charges & transportation charges complete in all respect of 11/0.4 kv, 25 kva dtr