Web Analytics Made Easy - StatCounter

Bio Chemistry Analyzer Tenders

Get complete information related to latest Bio Chemistry Analyzer Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Bio Chemistry Analyzer Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Bio Chemistry Analyzer Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :43556933 Due date: 29 Jun, 202629 Jun, 2026 9.97 Crore
Tender For corrigendum : re-tender for supply and installation of semi- automated bio chemistry analyzer under nfds & nuhm programme for the year 2024-25 under 15th finance budget

CTN :45583562 Due date: 26 Jun, 202626 Jun, 2026 NA
Tender For supply of socket set , force socket set , screw driver kit , screw driver , digital varner calliper , tool bag , spectrum analyser , circlip plier

CTN :45566478 Due date: 26 Jun, 202626 Jun, 2026 NA
Tender For optical spectrum analyser

CTN :45578897 Due date: 26 Jun, 202626 Jun, 2026 NA
Tender For providing of calibration services - mechanical, vector network analyser; torque; nabl labs; hybrid (detailed in scope of work),calibration services - mechanical, vector network analyser; torque; nabl labs; hybrid (detailed in scope of work),calibration services - mechanical, vector network analyser; torque; nabl labs; hybrid (detailed in scope of work),calibration services - electronics, micro wave spectrum analyser; frequency, power factor, phase angle; nabl labs; hybrid (detailed in scope of work),calibration services - electronics, micro wave spectrum analyser; frequency, power factor, phase angle; nabl labs; hybrid (detailed in scope of work),calibration services - electronics, micro wave spectrum analyser; frequency, power factor, phase angle; nabl labs; hybrid (detailed in scope of work),calibration services - electrical, electronics, dry block trmperature guage calibrator model 600s; temperature; nabl labs; hybrid (detailed in scope of work),calibration services - electrical, electronics, dry block trmperature guag

CTN :45538124 Due date: 22 Jun, 202622 Jun, 2026 NA
Tender For rf spectrum analyser

CTN :45536247 Due date: 23 Jun, 202623 Jun, 2026 NA
Tender For software upgrade modules for spectrum analyser r and s fpl1007

CTN :45446505 Due date: 22 Jun, 202622 Jun, 2026 NA
Tender For corrigendum : rate contract for medicine - stainless steel abdominal hysterectomy set, n.s.v set (s.s), g.v set, self abdominal detractor, m.t.p set., vaccine carrier (small size), x-ray digitalisation with high-end cr system (with installation & 1 yers. warrenty) console software with mulitmodality work station the cr system should have advances workstation provided with 17" high resolution monitor, keyboard & ouse, with the fol., digital ultrasound machine colour dopler (high resolution ) with 4 probe, semi auto analyzer, fully automated bio-chemistry analyzertechnical specificationsthroughput-150t/hr (constant with both mono and double reagent)system function-random access/stat/batchtest method-end point, fix time, kinetic, (single/double reagents chemistry, mono/ bio-chromatic measurements)calculation methods-1 point linear, 2 point linear, exponential, logit log3p, logit log 4 p, logit log 5p, spline, line graph, k factorblank-reagent blank, sample blank, pre sample blank, pre reagent blanksample tray-40 position, sample volume :2-30 ui, 0.1 ul increment, micro cup, & test tube can be used for samplereagent tray-80 position, reagent volume: 20-300 ul, 1 ul incrementmixing system-teflon coated mixersample probe-1 needle with liquid detector, shock sensoroptics-halogen-tungsten lamp, absorbance range: 0-4.0 abs resolution: 0.0001 abs.diffraction photometry with wave length: 340, 405, 450, 505, 546, 578, 630, 700nm & 4 more optionswash station-12 step washing, 4 needle wash station, 1 dry pad, external needle cleaningcalibration-linear and non-linearqc-multi-level qc setup with levy-jennings graph and westgrads multi rules with mean sd, and cvwater consumption-not more than 6l/hrtemperature-reagent: 2-14 c (24 hr refrigeration), reaction cuvette: 37c 0.1 humidity- 80%system interface-usbpower requirement-ac 220v 10%, 50/60 hzdimensions-750 mm*560mm*530mm, hotair oven, binocular microscope (olampus), centri fuge machin (good quality), micropipette (0-50 microliter), micropipette (0-500 microliter), micropipette (0-1000 microliter), microtips (0-50 microliter), microtips (0-1000 microliter), bed side screen with cloth 1"round pipe with wheel, sponge holding (all size), artery forceps 6" curved, artery forceps 6" straight., artery forceps 8" curved, artery forceps 8" straight., artery forceps 4" straight., alliys tissue forcep (all size curved straight), mosquito forcep (all size curved straight), scissor 6 " curved (all size), scissor 6 " straight (all size), scissor mosquito straight. (all size curved, straight), diatheromy (machine), laparoscopic instrument full set (best quality), needle holder 8 "curved, needle holder 8 " straight, needle holder 6 "curved, needle holder 6 " straight, needle holder 4 "curved, needle holder 4 " straight, doner couch (3 motor), blood weighting mechine, blood band refrigerator (300 bag) temp.display outside, elisa reader with washer mechine with printer & ups., doner couch (3 motor), blood weighting mechine, blood band refrigerator (300 bag) temp.display outside ( best quality), fully automated chemiluminescence analyzer(clia) 1. system should be fully automated walk -away with continuous loading facility.2. analyzer should have able to perform thyroid, bone, cardiac, fertility, diabetes and anemia profile test.3. working principle of system should be micron super paramagnetic particles platform with alp labeled reagents and amppd substrate.4. must have 3 phase magnetic separation with precisely controlled temperature.5. analyzer should have photon counting detection mode with photomultiplier photo counter with led reference module.6. the analyzer must have vortex non-touch mixing which can reduce carryover., 7. throughput of the system should be more than 180 tests in a hour.8. system should have 15 reagents onboard with onboard 2 -8 nonstop refrigeration facility 9. system should have at least 50 sample positions and continuous loading facility.10. system should have cont

Central Government/Public Sector

CTN :45486707 Due date: 10 Jun, 202610 Jun, 2026 NA
Tender For supply of semi automatic bio chemistry analyzer as per detailed specifications attached. [ warranty period: 36 months after the date of delivery ] ]

CTN :45318504 Due date: 15 Jun, 202615 Jun, 2026 14.65 Crore
Tender For corrigendum : tender for supply of tarang ate spares against sr 2025 26 sor 1029 - interface module power supply loom , spu lru loom 1 , du lru loom , difm lru loom , mass lru loom , rf lru loom 1 , ate self test loom , power supply module , spectrum analyser , blanking signal generator , interface module main assy , cable assy ccu , rf switching module mk ii , dome loom , spu lru loom 2 , bit loom , bnc to bnc cable adapter for oscilloscope , bnc loom 1 , 1553 cable bnc loom3 , cpu for ate mk ii , adapter n m smc f , oscilloscope , signal generator , bta mk 1a , personal computer , gpib cable w 19 w21 , rf cable assembly type 2 , rf cable assy type 3 , sma st plug-sma st plug shf 8 mr 5840 mm rf cable assembly type 1 , lru power supply loom , rfsm loom

Central Government/Public Sector

CTN :45394839 Due date: 19 Jun, 202619 Jun, 2026 NA
Tender For supply of divisional purchase of laboratory reagent for erba em200 fully automatic bio-chemistry analyzer.
 Loading, Please wait...

Connect us via What's Up