Get complete information related to latest Blue Tip Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Blue Tip Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Blue Tip Tenders.
Tender For lab kits/reagents/consumable item for blood bank-, anti a blood grouping (anti a monoclonal serum) -10 ml, , anti a lectin-1x10 ml, , anti ab antisera-1x10 ml, , anti b blood grouping (anti b monoclonal serum) -10 ml, , anti d (rn) blood grouping serum -10 ml, , anti h lectin-1x10 ml, , adhesive plaster 4 inch wide, , band aid adhesive strip, , blood weighing machine (0-1 kg), , bovine albumin -1x10 ml, , coomb's antisera-1x10 ml, , double blood bag, , lancet, , multi channel tips (0.5-10 ul-compatible) -1x1000, , multi channel tips (10-100 ul-compatible) -1x1000, , multi channel tips (30-300 ul-compatible) -1x1000, , multi channel tips (50-50 ul- compatible) -1x1000, , pediatric blood bag, , rpr/vdrl test kit, , rubber ball for donor use, , signal cpda 350 ml blood bag blood collection bag made up of dehp(di-2-ethyihexylphthalate) plasticized pvc collapsible non vented sterile containers with collecting tube for completely closed system to avoid the chances of contaminating.single blood bag capacity -350ml. needle-16 gauge ultra thin walled and straight. blood bag tube should have multiple printed id/segment numbers. (external port should be tamper proof and, , shouldn't be recapped.anticoagulant_cpda-1(49ml.) it should be clear & colour less.), , tissue paper roll, , tornic belt, , triple blood bag 450 ml with sagm mother bag of triple blood bag should have 450ml capacity with 63ml cpd solution and is connected to one satellite transfer bag of 400ml capacity and one satellite transfer bag of 400ml with 100ml sagm. mother bag should be 35mm to 50mm thickness to prevent breakage during centrifugation and the inner diameter of the tube should be standard measurement. needle should be 16g with triple. bevel design to reduce penetration force and enable painless vain puncture. blood bags and its packing should be properly labeled with batch no. mfg date and date of expiry. product labels should be bar-coded as per rule. complies to iso 3826 and quality of components stored as per indian drugs and cosmetics act. for the manufacturers have to produce documentary evidence from the laboratories approved by government of india., , weighing machine (donor), , disposable bluetips for microplpettes (2-200ui) -1x1000, , disposable yello tips for microplpettes (200-10010ui)- 1x1000, , finn pipette variable volume (100-1000 ul), , finn pipette variable volume (10-100 ul), , hbsag elisa test kit 4th gen. hbsag elisa test kits (specification-sensitivity & specificity should be100% must be able to detect 0.5 or less ng/ml. 4th generation hbsag)- test kits must have a long shelf life. detects all known 11 sub-types of hbv and also mutant strains can be used on any manual/semi-automatic system of elisa. 1x96 test., , 1. the kit to be procured should have approval of the statutory authority in its country of origin., , 2. in case of imported kits it should have been registered and licensed in india by dcg (i)., , 3. in case of indigenous manufacturers they shall have license issued by the competent authority defined under drugs and cosmetics act, 1940, after appropriate evaluation by the centers approved by dcg (i)., , hbsag rapid test kit (rapid test) 4th gen. specification-sensitivity & specificity should be100% must be able to detect 0.1 or less iu/ml. it should detects major vaccine escape mutants14t126n,t126s, q129r, q129hq129l, m133h, m133l,k141 e,p142s,t143k,d144a, g145r,t123a, p120q it should have single step procedure, subtype serotype-a/h,a/e,a/f,d/g,d/f,d/g specimen: serum/plasma, finger stick whole blood and vein puncture whole blood, , hcv elisa test kit, 4th generation, , 1. microplate elisa coated with recombinant/synthetic peptide antigens for core, ns3, ns4 and ns5 and antibody to hcv core antigen., , 2. adequate documents detailing the principle, components, bio-safety, methodologies, validity criteria, interpretation of results, performance characteristics, storage conditions, limitation of assays, manufacturing &a
Tender For supply of items for protein studies - ml040 to 500ml 5x tris sds buffer ph 500ml , ml039 to 500ml 2.5 x tris sds buffer ph 500ml , 10x tris glycine sds gel running buffer , acrylamide bisacrylamide solution 30 percent , prestainer protein ladder 10ln , bradford reagent 500ml , tris free base 500gm hhimedia , grm6365 to 500g di sodium hydrogen phosphate dihydrate , potassium dihydrogen , ml016 to 500ml 50 xtae used for gel electrophoresis , ml013 to 500ml to 1m tris cl ph 8 , ml123 to 1ktsilver staining kit , lysozyme 5gm , cms1889 to 1grifampicin 1gm , ammonium sulphate 500 gm , dodecyl sulphate sodium salt for mb 25gm , parafilm m 2 x 250 1pk roll , silver sulphate hi lr 25gm , albumin bovine fraction v 5gm , sd028-1vl penicillin g p 10units , storage vials pp 10ml sterile 300 pk pack tarson , glutaraldehyde solution 25 percent 25ml
Tender For corrigendum : e tender for lab items - drabkin solution for hb estimation, tlc dilueting fluid, tlc pipette, dlc diluting fluid, dlc pipette, platelate count fluid, esr pipette disposable, anti a sera, anti b sera, anti d sera ( igg & igm), anti human globulin ( coombs reagent), normal saline, test tube glass 12 x75, test tube glass 12x100, droper plastic, slide pkt iso mark, cover slips 18x18, giemsa stain, leishman stain, paraffin oil, slide tray aluminum, distilled water, methanol, reticulocyte count fluid, methylene blue soln, brilliant cresyl blue soln, eosinophill count fluid, hemocytometer ( counting chamber ), bt ct capillary, filter paper, stop watch/timer, alcohol swabs, sickling test for sickle cell anemia, sickling rapid test for sickle cell anemia, nestroft test for screening of thalessemia, dcip for screening for hbe hemoglobinopathy, quantitative test g6pd deficiency, malaria rapid card test, pt reagent, sodium citrate tube for pt test, aptt reagent, calcium chloride soln, hcg ( pregnancy card), urine strips for ph,sg,tlc,glu,bil,uro,ketone,protein,nitrate, urine container plastic 30ml, test tube disposable plastic 12x100 ( 4 " ), urine strips for microalbumin, urine strips for acr, test kit for stool for ova and cyst, test kit for occult blood, semen diluting fluid, dengue rapid card test (igg,igm & ns1 ag combo), typhoid card test antibody, rpr /vdrl test for syphilis ( rapid card tests), rapid test card for the simultaneous detection of malara pv/pf antigen, s.thphi ( igm antibodies) and dengue ns1 antigen from a single card ( combo), hiv rapid card test with single step procedure ( serum and plasma), hbsag rapid card test 0.1 iu/ml senstivity, anti hcv rapid card test, rapid test card for the simultaneous detection of hiv 1& 2,hcv,hbsag ,syphilis from a single card ( combo), afb stain kit, widal test kit, blood sugar kit, gtt test kit, bilirubin total & direct kit, creatinine kit, urea test kit, uric acid test kit, sgpt test kit, sgot test kit, alkanine phosphate test kit, total protein test kit, albumin test kit, globulin test kit, total cholesterol test kit, triglycerides test kit, vldl direct test kit, hdl direct test kit, ggt test kit, amylase test kit, iron test kit, tibc test kit, hba1c test kit, s.calcium kit, s.magnesium test kit, acid phosphatest test kit, grams stain soln, thorat swap for diphitheria, visual inspection acetic acid, rk 39 for kala azar by rapid card test, smear for filaria, montex test 5tu, montex test 10tu, tuberculin syring for montex test, troponin i rapid card test, trop t rapid card test, ra quantitative test kit, crp quantitative test kit, aso quantitative test kit, bluetips, clot activator non vaccum tube double cap, edta nonvaccum tube double cap, jsb stain 1, jsb stain 2, keto stix, lugol iodine, methanol 5ltr, microscope bulb, printer paper roll 57mmx10mtr, printer paper roll 57mmx20mtr, sodium citrate soln, sodium hypochlorite soln, tissue paper roll, urine strips 04 parameter, yellow tips, electrolyte analyzer as per enclsoed technical specifications, 5 part hematology analyzer as per enclosed technical specifications, fully automated immunoassay analyzer ( clia) as per enclosed technical specifications, semi automated bioschemistry analyzer as per enclosed technical specifications