Tender For tender for supply of 60watt led flp light type well glass , lamp led 240v 12 watt , fixt light 230v 18watt led tube light screw , lamp led 240v 18 watt , fixt light 230v 18watt led tube light screw , h.t. fuse for p.t 11kv switch 5v. , lt voltage detector non-contact range 30v 650v , insulator spout bushing 11kv/400a for 11kv ht switch , auxiliary tripping relay for 11kv ht switch type jrv-171 single phase aux supply 110v 1pole or equivalent. , switch cum out selector 110v for 3.3kv h.t. switch , fixed contact assy 400 amps 2450560 , moving contact 400 assy 2450980 , insulator spout bushing 11kv/400a for 11kv ht switch , shunt trip assy 230v/110v ac p.no.- uss016 , vcb closing coil (501000). , heavy duty glass fibre / frp highly insulated , selfsupporting type ladder with platform at top height- 6 feet. , suit , arc flash 8cal/cm2 size-xl , moving contact with terminal for ocb switch. lt5551c , fixed contact assy. 200amp. for ocb switch , 453201 , no volt coil assy. bt 1870s/ st1870s , insulation tester digital meggar tester type digital megger measurement range 5 kv , digital clamp meter 0- 1200 amp. 0-1000 amp. ac/d digital , kit spare mnx 400/300 amp or equivalent. , isolator 600 amp. 3 pole complete off-load , mccb 100a , type lm 100c ge power control , , crimping tool hand operated 10-185mm2 , power contector complete set , 2no + 2nc , 25 amps coil or equivalent , barrel pump hand operated rotary type suitable for 210 ltr. drums , 3 pole power contactors type mnx complete set , 650 amp , 2no + 2nc , 415volt coil voltage or equivalent
Tender For corrigendum : manufacture, fabrication, supply,erection, testing and commissioning with 1x8 mva pr.tr,stn transformer, associated equipments, accessories, control panels, control room and electrical works at o.krishnapuram in trichy metro under tkc thro e tener - electrical material supply, power transformer 33/11kv, 8mva power transformer with oltc, breaker along with ct for outdoor ss 33 kv (gc) vcb (out door) 1250a, 26.3ka per 3 sec., 3 pole gang operated soild dielectric insulated with permanent magnetic actuator operating mechanism with inbuilt vcb bushing embedded dry type epoxy resin cast ct (600-300/1-1a) with structure and complete accessories with breaker platform., 11kv (lv) vcb (out door) 12 kv, 1250a, 26.3ka per 3 sec., 3 pole gang operated soild dielectric insulatedwith permanent magnetic actuator operating mechanism with inbuilt vcb bushing embedded dry type epoxy resin cast ct (1200-600/1-1a) with structure and complete accessories with breaker platform., 11kv (feeder) vcb (out door) 12 kv, 1250a, 26.3ka per 3 sec., 3 pole gang operated soild dielectric insulated with permanent magnetic actuator operating mechanism with inbuilt vcb bushing embedded dry type epoxy resin cast ct (400-200/1-1a) with structure and complete accessories with breaker platform., potential transformer 33kv potential transformer with tc (single phase unit), 11kv potential transformer with tc (three phase unit), panels ac panel for 33kv ss, 110 v dc annunciation panel type b, 110v dc indoor c&r panel for gc breaker, 110v dc indoor c&r panel for lv breaker, 110 v dc indoor c&r panel for twin feeder, control cables, junction box and accessories 14c x 2.5 sq.mm copper cable armoured, 8c x 4 sq.mm copper cable armoured, 4c x 4 sq.mm copper cable armoured, 4c x 2.5 sq.mm copper cable armoured, 2c x 2.5 sq.mm copper cable armoured, isi mark 19 / 22 mm cable gland as directed by the field engineer., isi mark 25 mm cable gland as directed by the field engineer., isi mark cable 28 mm gland as directed by the field engineer., lugs, ferrules, sleeves, cable tie, insulation tape and other accessories for providing cable core end termination, supply of gi chequerred plate 6mm thickness, junction box supply of ct/pt junction box made out of 14swg (2mm) m.s.sheet wherever required as directed by the field engineer. the box shall be vermin proof shall have sturdy hinges, provision for mounting terminal blocks and lockingarrangements including cost of all materials. 400w x 300h x 150d, supply of ac junction box of size 535x310x127mm of 18swg ms sheet including hrc fuse unit-18 nos. should be fitted with base, consumables etc. (the box shall be vermin proof, shall have sturdy hinges and lockingarrangements), supply of mounting channel suitable for cbtm 5 terminal block in panel /box as required and as directed by the field engineer., supply of disconnected type terminal block suitable for ct circuits in panels/ box as required & as directed by the field engineer, supply of isi mark bakelite hrc fuse holder with fuse of 2/5/10/16 amps reputed make in panels/ boxes for ac/dc/pt circuits wherever required as directed by the field engineer. 16 amps - fuse holder with hrc fuse, 63amps - fuse holder with hrc fuse, bus & bus materials zebra acsr conductor, 2.0" / 50 mm aluminium bus bar (thickness:5 mm), 22/33 kv pt insulators, 11kv pt insulator, 11kv, 120kn disc insulators (antifog), strung bus eye bolt of 18 - 20 mm dia gi rod of required length suitable for 33kv, 22kv and 11kv strung bus including cost of gi rod and 2nos gi nuts & washer as directed by the field engineer., clamps and connectors tension fitting clamp 4 bolted for zebra, t clamp for 2" bus to single zebra, t clamp for zebra to zebra, switchend clamp for single zebra, switchend clamp for 2" busbar, reducer clamp for 2" bus to zebra, pg clamp for zebra, free end clamp for 2"busbar, corana bell for 50mm bus bar, switch end clamp for mink, seating block for 2" bus bar(for g
Tender For supply of lv terminal energy efficient bushing clamp with anti-theft insulation protection (smart connector) for 25kva to 315kva ratings of distribution transformers.
Tender For dismantling primary and secondary h t l t cable by opening the terminal bushing taking out h t and l t cable from each terminal again dismantling l t transformer 75 k v a